Installation Guide
NI-2100 NetLinx Integrated Controller
The NI-2100/ICS is ideal for control and automation of medium-sized rooms and multi-room 
applications. The NI-2100 has 64MB of onboard RAM and is Device Discovery enabled to 
simplify programming by standardizing device and function definitions, default touch panel 
button assignments, and control and feedback methods.
ATTENTION!
Verify you are using the latest NI firmware for the on-board Master. Verify you are using the 
latest version of NetLinx Studio (available for download from www.amx.com).
Specifications     
FIG. 1  NI-2100
NI-2100 Specifications
Models Available: • NI-2100 Controller (FG2105-04)
The NI-2100 can be upgraded to provide one ICSHub and two 
ICSNet ports by installing the optional ICSNet daughter card 
(FG2105-10 - see Other AMX Equipment) 
• NI-2100/ICS Controller with ICSNet (FG2105-14)
Dimensions 
(HWD):
• 3 1/2" x 17" x 3 1/2" (8.8 cm x 43.2 cm x 8.8 cm)
• RU: 2
Power 
Requirement:
700 mA @ 12 VDC
Memory: • 64 MB SDRAM
• 1 MB Non-volatile (NV) SRAM
Compact Flash: 2GB or greater (upgradeable to 4GB - see Other AMX Equipment).
Note: AMX may increase Flash size at any time in response to 
market availability.
Weight: 4.50 lbs (2.04 kg)
Enclosure: Metal with black matte finish
Certifications: FCC Part 15 Class B, CE, and IEC 60950
Front Panel LEDs:
LINK/ACT 
(green): 
Blinks when the Ethernet cables are connected and terminated 
correctly. Also blinks when receiving Ethernet data packets.
Status (green):  Blinks to indicate that the system is programmed and 
communicating properly.
Output (red):  Blinks when the Controller transmits data, sets channels On and 
Off, sends data strings, etc.
Input (yellow):  Blinks when the Controller receives data from button pushes, 
strings, commands, channel levels, etc.
RS-232/422/485 
(red / yellow): 
3 sets of LEDs light to indicate that DB9 Ports 1 - 3 are transmitting 
or receiving RS-232, 422, or 485 data (red = TX, yellow = RX).
Relay (red): 4 LEDs light to indicate the relay channels 1 - 4 are active (closed). 
These LEDs reflect the state of the relay on Port 4.
IR/Serial (red):  4 LEDs light to indicate the IR/Serial channels 1 - 4 are transmitting 
control data on Ports 5 - 8. LED indicator for each IR port remains lit 
for the length of time that IR/Serial data is being generated.
I/O (yellow): Lights when the I/O channels 1 - 4 are active. The LED for each I/O 
port reflects the state of that particular port.
LINK/ACT LED
STATUS LED
INPUT LED
OUTPUT LED RS-232/422/485 Status LEDs
RELAY Status LEDs
IR/SERIAL Status LEDs
I/O Status LEDs
front
rear RS-232/422/485 (Ports 1-3)
ICSNet/ICSHub Ports
(provided by optional 
ICSNet daughter card)
Relays (Port 4)
I/O (Port 9)
IR/Serial (Ports 5-8)
PROGRAM Port
CONFIGURATION DIP Switch
ID Pushbutton
ETHERNET
10/100 Port
AxLink Port
12 VDC PWR Connector
NI-2100 Specifications (Cont.)
Rear Panel Components:
RS-232/422/485 
(Ports 1 - 3):
3 RS-232/422/485 control ports using DB9 (male) connectors with 
XON/XOFF (transmit on/transmit off), CTS/RTS (clear to send/
ready to send), and 300-115,200 baud.
ICSNet:  2 RJ-45 connectors for ICSNet interface (provided by optional 
ICSNet daughter card).
ICSHub Out:  RJ-45 connector provides data to a Hub connected to the Controller 
(provided by optional ICSNet daughter card).
Relay (Port 4): • 4-channel single-pole single-throw relay ports 
• Each relay is independently controlled.
• Supports up to 4 independent external relay devices
• Channel range = 1-4
• Each relay can switch up to 24 VDC or 28 VAC @ 1 A
• 8-pin 3.5 mm mini-Phoenix (female) connector provides relay 
termination
Digital I/O 
(Port 9): 
4-channel binary I/O port for contact closure with each input being 
capable of voltage sensing. Input format is software selectable with 
interactive power sensing for IR ports.
Note: The I/Os on this card are not dry closure; they are electronic 
switches that float at 5V when Off. Therefore, they should not be 
expected to work in situations that require true dry contact (or dry 
closure). The I/Os do work with AMX PC1, PC2, UPC20 and 
UPC20+. 
IR/Serial 
(Ports 5 - 8): 
4 IR/Serial control ports support high-frequency carriers of up to 
1.142 MHz with each output being capable of two electrical formats: 
IR or Serial. 
• 4 IR/Serial data signals can be generated simultaneously. 
• IR ports support data mode (at limited baud rates and wiring 
distances).
Program Port:  RS-232 DB9 connector (male) can be connected to a DB9 port on a 
PC. This connector can be used with serial and NetLinx program-
ming commands, as well as other DB9 capable devices, to both 
upload/download information from the NetLinx Studio program.
Configuration DIP
Switch: 
Sets the communication parameters for the Program port (see Baud 
Rate Settings).
ID Pushbutton:  Sets the NetLinx ID (Device only) assignment for the device.
Ethernet Port:  RJ-45 connector provides TCP/IP communication. This is an Auto 
MDI/MDI-X enabled port, which allows you to use either straight-
through or crossover Ethernet cables.
The Ethernet Port LEDs show communication activity, connection 
status, speeds, and mode information:
•SPD (speed) - Yellow LED lights On when the connection speed 
is 100 Mbps and turns Off when the speed is 10 Mbps.
•L/A (link/activity) - Green LED lights On when the Ethernet cables 
are connected and terminated correctly, and blinks when 
receiving Ethernet data packets.
AxLink Port:  4-pin 3.5 mm mini-Phoenix (male) connector that provides data and 
power to external control devices. Green AXlink LED indicates the 
state of the AXlink port.
Power Port:  2-pin 3.5 mm mini-Phoenix (male) connector.
Operating 
Environment:
• Operating Temperature: 0° C (32° F) to 50° C (122° F)
• Operating Humidity: 20% to 85% RH
• Heat Dissipation (Typical): 28.7 BTU/hr
Included 
Accessories:
• 2-pin 3.5 mm mini-Phoenix (female) PWR connector (41-5025)
• 4-pin 3.5 mm mini-Phoenix (female) AXlink connector (41-5047)
• 6-pin 3.5 mm mini-Phoenix female I/O connector (41-5063)
• 8-pin 3.5 mm mini-Phoenix female Relay connector (41-5083)
• Installation Kit (KA2105-01):
8-pin Relay Common Strip 
4 rack mount screws 
4 washers 
• 2 CC-NIRC NetLinx IR Emitter Cables (FG10-000-11)
• 2 removable rack ears (62-2105-07)
Other AMX 
Equipment: 
• 2-pin 3.5 mm mini-Phoenix male connector (41-5026)
• CC-COM Programming Port Cable (FG10-727)
• CC-NSER IR/Serial cable (FG10-007-10)
• ICSNet daughter card (FG2105-10)
• NCK, NetLinx Connector Kit (FG2902)
• STS, Serial To Screw Terminal (FG959) 
• Upgrade Compact Flash (factory programmed with firmware):
NXA-CF2NI4G, 4 GB Flash Upgrade (FG2116-07)
Specyfikacje produktu
| Marka: | AMX | 
| Kategoria: | sterownik | 
| Model: | FG2105-04 | 
| Waga produktu: | 2040 g | 
| Zakres temperatur (eksploatacja): | 0 - 50 °C | 
| Zakres wilgotności względnej: | 20 - 85 % | 
| Port RS-232: | 3 | 
| Wymiary produktu (SxGxW): | 88 x 432 x 88 mm | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z AMX FG2105-04, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje sterownik AMX
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         21 Czerwca 2024
                        
                    
                                                            
                        
                         20 Czerwca 2024
                        
                    
                                                            
                        
                         20 Czerwca 2024
                        
                    
                                                            Instrukcje sterownik
- Zephyr
- Eurolite
- Lab Gruppen
- Manfrotto
- One For All
- SBS
- IHome
- ION
- KanexPro
- Reely
- Perel
- GeoVision
- Ikan
- PTZ Optics
- Alfatron
Najnowsze instrukcje dla sterownik
                        
                         2 Października 2024
                        
                    
                                                            
                        
                         21 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024