Instrukcja obsługi Braun Age Precision PRT 2000

Braun termometr Age Precision PRT 2000

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Braun Age Precision PRT 2000 (4 stron) w kategorii termometr. Ta instrukcja była pomocna dla 8 osób i została oceniona przez 4.5 użytkowników na średnio 4.9 gwiazdek

Strona 1/4
English
Description
1. Measuring sensor 5. Large display with colour-coded indicator lights
2. Extra gentle exible tip 6. Battery compartment cover (back)
3. On/O button (side) 7. Protective cap
4. Age Precision™ button
Warnings and Precautions
• YourBraunDigitalThermometerisa3-in-1thermometersuitableforunderarm,oralorrectaluse.
Whichevermethodisused,itisrecommendedthatfor15minutespriortouse,avoideatingordrinking
anyliquids,exercising,takingshowersorbaths,orsmoking.
• Thisthermometerisintendedforhouseholduseonly.Thisproductisnotintendedtodiagnoseany
disease,butisausefulscreeningtoolfortemperature.Useofthisthermometerisnotintendedasa
substituteforconsultationwithyourphysician.
• TheAgePrecision™featureisnotintendedforpre-termbabiesorsmall-for-gestationalagebabies.The
AgePrecision™featureisnotintendedtointerprethypothermictemperatures.
• Pleaseconsultyourphysicianifthethermometershowselevatedtemperature.High,prolongedfever
requiresmedicalattention,especiallyforyoungchildren.
• Parents/guardiansshouldcallthephysicianuponnoticinganyuntowardsign(s)orsymptom(s).For
example,achildwhoexhibitsirritability,vomiting,diarrhea,dehydration,changesinappetiteor
activity,evenintheabsenceoffever,orwhoexhibitsalowtemperature,maystillneedtoreceive
medicalattention.Childrenwhoareonantibiotics,analgesics,orantipyreticsshouldnotbeassessed
solelyontemperaturereadingstodeterminetheseverityoftheirillness.
• TemperatureelevationasindicatedbyAgePrecision™maysignalaseriousillness,especiallyin
neonatesandinfants,oradultswhoareold,frail,haveaweakenedimmunesystem.Pleaseseek
professionaladviceimmediatelywhenthereisatemperatureelevationandifyouaretaking
temperaturefor:
- Neonatesandinfantsunder3months.Consultyourphysicianimmediatelyifthetemperature
exceeds37.4°Cor99.4°F.
- Patientsover60yearsofage.Fevermaybebluntedorabsentinelderlypatients.
- Patients having diabetes mellitus or a weakened immune system
(e.g.HIVpositive,cancerchemotherapy,chronicsteroidtreatment,splenectomy).
- Patients who are bedridden
(e.g.nursinghomepatient,stroke,chronicillness,recoveringfromsurgery).
- Atransplantpatient(e.g.liver,heart,lung,kidney).
• Donotallowchildrenunder12yearsofagetotaketheirtemperaturesunattended.
• Donotallowchildrentowalkorrunduringtemperaturetaking.
• Thisthermometercontainssmallpartsthatcanbeswallowedorproduceachokinghazardtochildren.
Alwayskeepthethermometeroutofchildren’sreach.
• Donotmodifythisequipmentwithoutauthorizationofthemanufacturer.
• ManufacturingdateisgivenbytheLOTnumberlocatedatthebackofthethermometer.Therstthree
(3)digitsrepresenttheJuliandatethattheproductwasmanufactured,andthenexttwo(2)digits
representthelasttwonumbersofthecalendaryeartheproductwasmanufactured.Thelastidentiers
arethelettersthatrepresentthemanufacturer.
• Anexample:LOT:11614FAMimpliesthisproducthasbeenmanufacturedonthe116thdayofthe
year 2014.
What is new about Braun Age Precision™ Thermometer?
• Clinicalresearchshowsthedenitionoffeverchangeswithage1.Forexample,whatisanormal
bodytemperatureina4yearold,mayberegardedasafeverinanewborn.Braun’sAgePrecision™
thermometerisanageadjustablethermometerwithapatentedFeverInsight®colour-codeddisplay.
Itusesmedicalguidelinestointerprettemperatureandtakestheguessworkoutofinterpreting
temperaturefortheentirefamily.
• Temperaturereadingsvarydependingonthesiteofmeasurement.Anoraltemperatureisgenerally
0.1°C higher than underarm (axillary) temperature and rectal temperature is generally 0.6°C higher than
underarm temperature.1,2
Braun’s Age Precision™ feature is optimized for underarm temperature taking.
• Temperaturereadingsvaryfrompersontoperson.Thebestmethodtodetermineyourownnormal
temperatureistousethethermometerwhenyouarefeelingwell.Recordyourreadingtwiceaday
(earlymorningandlateafternoon).Taketheaverageofthetwotemperatures.Thisisconsideredyour
normalbodytemperature.Anyvariationfromitmayindicatesomesortofillnessandyoushould
consult your physician.
Itisimportanttorememberfeverisasymptom,notadisease,andisjustoneofthemanypossiblesignsof
illness.Ifyourchildexhibitssignsofaseriousillness,contactyourphysician
How to Use Your Braun Age Precision™ Thermometer
3 Simple Steps:
1. Switch on the thermometer by pressing the On/O button
Youwillhearashortbeepanddisplaysegmentcheckwillbeperformed.Afterthesegmentcheck,last
temperaturereadingwillbedisplayedfor2seconds.Subsequently,theageiconsandagerangewill
cycle,untiltheAgePrecisionbuttonispressed.
2. Select the age by pressing the AgePrecision™ button
WhentheAgePrecision™buttonispressed,theagerangeiconswillstopcycling,andstopontheage
range icon that was showing when the button was pressed. Keep pressing the button until the desired
agesettingisdisplayed.Thethermometerhas3agesettings:
• 0-3months
• 3-36months
• 36monthsuptoanadult
Aftertheageisselected,theagerangeiconremainssteadilylit.
Thedisplaywillshowthreedashedlinesandthethermometer
is ready to start the measurement.
3. Take the measurement by placing it on the measurement site.
Oncetemperatureriseisdetectedbythermometerinmeasurementmode,itwillbegintomeasure.
Ifthethermometerdoesn’tmeasureatemperaturerise,theageiconandthreedashedlineswillbe
shown until the thermometer automatically turns o.
Aftermeasurement(generally8secondsaftertemperaturechangeisdetected),theconrmation
beepindicatesthatanaccuratetemperaturemeasurementhasbeentaken:1longbeepfornormal
temperature,10shortbeepsforelevatedandhightemperature.Theresultwillbeshownonthe
display.InterpretthereadingwiththehelpofthecolourcodedFeverInSight®displaythatusesmedical
guidelinestointerprettemperaturebasedontheageofthepatients.
Note:Usershavetoshutdownthethermometerandstartupagaintotakeanothermeasurementand/or
changeagesetting.TheBraunAgePrecision™thermometerturnsoautomatically
20secondsafterthemeasurementorafter90secondswithoutmeasurement.
Reading the measurement with Fever InSight® Colour Coded Display
BraunAgePrecision™ThermometercomeswiththepatentedFeverInSight®displaythatoersacolour
indication along with the temperature readout and helps you better understand the temperature reading
basedonpatients’age.
- Green backlight indicates readingnormal
- Yellowbacklightindicateselevated temperature
- Redbacklightindicateshigh temperature
TheFeverInSight®colourcodeddisplayforinterpretingfeverhasbeendesignedforuseintheunderarm
mode only according to the table below.
Site Age range Green
Normal temperature
Yellow
Elevated temperature
Red
Hightemperature
Underarm
0-3 Months 35.7 – 37.3 °C > 37.3 °C
3-36 Months 35.3 – 37.4 °C 37.5–38.4°C >38.4°C
36 Months-
adult 35.3 – 37.4 °C 37.5 – 39.4 °C > 39.4 °C
Ifyouusethethermometerintheoralorrectalmodebyplacingitatthosesites,pleasedonotusethe
displaylightsprogrammedintothethermometerfordeterminingfever.Instead,refertotheoralandrectal
tablesrespectivelyasshownbelowtodetermineifyouhaveafever.
Site Age range Normal temperature Elevated temperature High temperature
Oral
0-3 Months 35.8–37.4°C > 37.4 °C
3-36 Months 35.4 – 37.6 °C 37.7–38.5°C >38.5°C
36 Months
to Adult 35.4 – 37.7 °C > 39.4 °C37.8-39.4°C
Rectal
0-3 Months 36.3 – 37.9 °C > 37.9 °C
3-36 Months 35.9–38.1°C 38.2–39.0°C > 39.0 °C
36 Months-
adult 35.9–38.2°C 38.3–39.9°C > 39.9 °C
Note:Duetohumanphysiology,temperaturemeasurementstakenfromdierentsitesonthesame
personshowvariability.Forexample,rectalreadingstendtorunhigherthanoralaswellasunderarm
readingstakenfromthesameperson.
Tips for Measuring at Dierent Sites
Under-the-arm (axillary) use
Thismethodisusedforbabiesandyoungchildren.
1. Wipe the underarm with a dry towel.
2.Placetheprobetipunderthearmsothetipistouchingtheskinandpositionthepatient’sarmnextto
thepatient’sbody(Fig.1).
Withayoungchild,itissometimeshelpfultohugthechildtokeeptheirarmnexttotheirbody.This
ensures that the room air does not aect the reading.
3.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
4.Turnothethermometerandcleanasrecommendedbelow.
Fig.1 Fig.2
Oral use
Thismethodissuitableforchildrenwhoareoldenoughtosafelykeepthethermometerinsidethemouth.
1.Itisimportanttoplacethetipofthethermometerwellunderthetongueoneithersidetogetagood,
accuratereading.Placesensortipinareasmarkedwith“√”underthetongue(Fig.2).Keeppatient’s
mouth closed and make him/her sit still to help ensure an accurate measurement.
2.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
3. Turnothethermometerandcleanasrecommendedbelow.
Rectal use
Commonlyusedforbabies,youngchildren,orwhenitisdiculttotakeanoralorunderarmtemperature.
1.Coverthethermometer’stipwithaprobecoverandlubricatewithawater-solublejellyforeasier
insertion.
Donotuseapetroleumjelly.Readthelabelofthelubricanttobesureyouareusingtherightkind.
2.Laythepatientonhis/herside.Ifthepatientisaninfant,theproperpositionforababyistolayonits
stomachwithlegshangingdown,eitheracrossyourkneesorattheedgeofabedorchangingtable.
Thispositionstheinfant’srectumforsafeandeasyinsertionofthethermometer.
3.Gentlyinsertthetipofthethermometer 1.3cmor1/2inchintotherectum.IfyouNO MORE THAN
detectresistance,stop.Holdthethermometerinplaceduringmeasurement.
4.Whenthepeaktemperatureisreached,beepsignalswillsound.Thetemperatureisnowconrmed.
Whenthethermometerisremovedfromthemeasuringsite,associatedFeverInsight™colourwilldisplay.
5.Turnothethermometerandcleanasrecommendedbelow.
Memory
Whenthethermometeristurnedon,thedisplaywillshowatest,afterwhichthelastmeasured
temperaturewillbeshownforapproximately1second.Letter“M”willbedisplayednexttothe
temperature reading.
Changing the Temperature Scale
Withpowero,pressandholdtheOn/Obuttonforabout5secondsuntil“---“withasteady“°C”or
“°F”appearsonscreen.ReleaseandpresstheOn/Obuttonagaintoswitchfromthecurrentscaletothe
alternatescaleandrelease.Afterabout3secondstheunitisreadyfortakingtemperatureinthechosen
scale and the age range icons start to scroll.
Care and Cleaning
• Cleantheprobetipbywashingwithsoapandwarmwaterorbydisinfectingwithrubbingalcohol(70%
isopropyl alcohol).
• Wipedrywithsoftcloth.
• DO NOT BOIL OR CLEAN IN DISHWASHER.Thiswillcausethethermometertonolongerfunctionand
will void the warranty.
• Donotwashtheunitwithanythinnerorchemicalsolvent
• Storeyourthermometerinadrylocation,freefromdustandcontaminantsandawayfromdirect
sunlight
Replacing the Batteries
WhenthebatterysymbolonLCDdisplaytwinklescontinually replace with new battery.
1.Insertcoinintoslot.RotatedooruntilslotislinedwithUNLOCKsymbol.
2.Replacebattery
3.RotatebatterydoortoLOCKEDposition.
Errors and Troubleshooting
Whenmeasuredtemperatureishigherthan42.9°C,LCDwilldisplay“Err°C”
andrelevantageicon.Redbacklightstaysonfor5seconds.
Whenambienttemperatureisoutofrange(seeProductSpecicationsbelow)
orothersystemerrorsoccursuchasshortorbrokencircuit,LCDwilldisplay“Err
toindicatesystemerror.Redbacklightstaysonfor5seconds.
Limited Two Year Warranty
Kazwarrantsthisproductagainstanydefectsthatareduetofaultymaterialorworkmanshipforaperiod
oftwoyearsfromtheoriginaldateofconsumerpurchaseorreceiptasagift.Thiswarrantyapplieswhen
usedfornormalhouseholduseinaccordancewiththeUseandCareManualandexcludesthebatteryand
damagetotheproductresultingfromaccidentormisuse.Thisproductisnotwarrantedwhenusedina
professionalenvironment.
InnoeventshallKazbeliableforanyspecial,incidental,indirectorconsequentialdamagesinconnection
withthepurchaseoruseofthisproductorcostsovertheoriginalcostofproduct.
Iftheproductshouldnotperformtospecicationswithinthewarrantyperiod,pleasecontactConsumer
Relationsat1-800-477-0457oremailatconsumerrelations@kaz.comorwritetoKazUSAInc,Consumer
RelationsDepartment,250TurnpikeRoad,Southborough,MA01772.InCanada,youcancontactus
at510BronteStreetS,Milton,ON,L7T2X6,Canada.Kazreservestherighttoreplaceanonconforming
productwiththemostcomparableproductcurrentlyavailable.Thisproducthasaveyearminimum
expectedlifetime.
Product Specications
Displayedtemperaturerange: 32.0°C-42.9°C(89.6°F-109.2°F)
Operatingambienttemperaturerange: 10–40°C(50–104°F)
andrelativehumidityrangeof15%~95%
Displayresolution: 0.1°Cor°F
Accuracyfordisplayedtemperaturerange MaximumLaboratoryError
35°C–42°C(95.9°F–107.6°F): ±0.1°C(±0.2°F)atanambientof23±5°C
outsidethisrange: ±0.2°C/0.4°F(within32.0°C-42.9°C(89.6°F-109.2°F))
Batterylife: 500timesmeasurementswithin2years
Servicelife: 2000measurements
Storage/Transporttemperature -25-55±2°Cand15-95RH%±5%
and relative humidity
Ifthedeviceisnotusedwithinspeciedtemperatureandhumidityrangesthetechnicalaccuracyofthe
measurement cannot be guaranteed.
Explanation of symbols
TypeBFappliedparts  Seeinstructionforuse
Operating temperature  Storagetemperature
Keep dry
IP22:Protectedagainstsolidforeignobjectsof12.5mmdiameterandgreater.Protectedagainstvertically
fallingwaterdropswhenthedeviceistiltedupto15degrees.
Thisthermometerisspeciedtooperateat1atmosphericpressureorataltitudeswithanatmospheric
pressure up to 1 atmospheric pressure (760-1060 hPa).
SeeInstructionforuseEquipmentwithtypeBFappliedparts
Subjecttochangewithoutnotice.
Thisapplianceconformstothefollowingstandards:
StandardReferenceEditionTitle:EN12470-3:2003Clinicalthermometers-Part3:Performanceofcompact
electrical thermometers (non-predictive and predictive) with maximum device.
EN60601-1:2006Medicalelectricalequipment–Part1:Generalrequirementsforbasicsafetyand
essentialperformance.
English
Français
GB
FR
Guidanceandmanufacturer’sdeclaration–electromagneticemissions
ThePRT2000equipmentisintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Emissions Test Compliance Electromagnetic environment – guidance
RFEmissions
CISPR11 Group 1
TheMEequipmentusesRFenergyonlyforit’sinter-
nalfunction.Therefore,itsRFemissionsareverylow
andarenotlikelytocauseanyinterferenceinnearby
electronic equipment.
RFEmissions
CISPR11 Class B Complies
HarmonicemissionsIEC
61000-3-2 Not Applicable
TheMEequipmentis
solely battery powered.
Voltageuctuations/
icker emissions Not Applicable
Non-Life Support Equipment Separation Distance Calculation
(3Vrms / 3V/m compliance)
Ratedmaximumoutput
poweroftransmitter(W)
Separationdistanceaccordingtofrequencyoftransmitter(m)
150kHzto80MHzin
ISMbands
80MHzto800MHz 800MHzto2.5GHz
d = [ 7 ] P
E1
0.01 / 0.12 0.23
0.1 / 0.730.38
1 / 1.2 2.3
10 / 7.33.8
100 / 12 23
d = [
3,5] P
V
1
d = [3,5] P
E1
Guidance and manufacturer’s declaration – electromagnetic immunity
ThePRT2000isintendedforuseintheelectromagneticenvironmentspeciedbelow.
ThecustomerortheuserofthePRT2000shouldassurethatitisusedinsuchanenvironment.
Immunity test IEC60601 test
level
Compliance
level
Electromagnetic environment
– guidance
Electrostatic discharge
(ESD)
IEC61000-4-2
±6kVContact
±8kVAir Complies
Floorsshouldbewood,concrete,
orceramictile.Ifoorsare
coveredwithsyntheticmaterial,
the relative humidity should be
atleast30%
RadiatedRF
IEC61000-4-3
3V/m80MHzto
2.5GHz Complies
Fieldstrengthsoutsidethe
shieldedlocationfromxedRF
transmitters,asdeterminedby
anelectromagneticsitesurvey,
shouldbelessthan3V/m.
Interferencemayoccurinthe
vicinityofequipmentmarked
withthefollowingsymbol:
Separationdistancecalculation
providedabove.Ifaknown
transmitterispresentthespecic
distance can be calculated using
the equations.
ConductedRF
IEC61000-4-6
3Vrms150kHzto
80MHz
Not Applicable
(no electrical
cabling)
Electricalfasttransient
IEC61000-4-4
±2kVpowerline
±1kVI/Olines Not Applicable
TheMEequipment
is solely battery powered.
Surge
IEC61000-4-5
±1kV
dierential
±2kVcommon
Not Applicable
Powerfrequency
magneticeld
IEC61000-4-8
3 A/m Complies
Powerfrequency
magneticeldsshouldbeat
levelscharacteristicofa
typical location in a typical
commercial or hospital
environment.
Voltagedips,short
interrupts and voltage
variations on power
supply input lines
IEC61000-4-11
>95%dip0.5
cycle
60%dip5cycles
70%dip25cycles
95%dip5sec.
Not Applicable
TheMEequipment
is solely battery
powered.
ENISO14971:2012Medicaldevices–Applicationofriskmanagementtomedicaldevices.
ENISO10993-1:2009Biologicalevaluationofmedicaldevices–Part1:EvaluationandTesting.
EN60601-1-2:2007Medicalelectricalequipment–part1-2:Generalrequirementsforbasicsafetyandes-
sentialperformance–Collateralstandard:electromagneticcompatibility–Requirementsandtests
EN980:2008Symbolsforuseinlabelingofmedicaldevices.
EN1041:2008Informationsuppliedbythemanufacturerofmedicaldevices.
EN60601-1-11:2010Medicalelectricalequipment--Part1-11:Generalrequirementsforbasicsafetyand
essentialperformance--Collateralstandard:Requirementsformedicalelectricalequipmentandmedical
electrical systems used in the home healthcare environment.
ThisproductconformstotheprovisionsoftheECdirective93/42/EEC.
MEDICALELECTRICALEQUIPMENTneedsspecialprecautionsregardingEMC.Fordetaileddescriptionof
EMCrequirementspleasecontactourConsumerRelationsDepartment.
PortableandmobileRFcommunicationsequipmentcanaectMEDICALELECTRICALEQUIPMENT.
Pleasedonotdisposeoftheproductinthehouseholdwasteattheendofitsusefullife.Disposal
can take place at your local retailer or at appropriate collection points provided in your country.
Toprotecttheenvironment,disposeofemptybatteriesatappropriatecollectionsitesaccordingto
national or local regulations.
1HerzogL,PhillipsSG.Addressingconcernsaboutfever.ClinPediatr(Phila)2011May;50(5):383-90.
2Sund-LevanderM,ForsbergC,WahrenLK.Normaloral,rectal,tympanicandaxillarybodytemperature
inadultmenandwomen:asystematicliteraturereview.ScandJCaringSci2002June;16(2):122-8.
Age Precision
Digital
Thermometer
PRT 2000
Age PrecisionMC
Thermomètre
numérique
Downloaded from www.vandenborre.be


Specyfikacje produktu

Marka: Braun
Kategoria: termometr
Model: Age Precision PRT 2000

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Braun Age Precision PRT 2000, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą