Instrukcja obsługi Dometic Pump SW24
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Dometic Pump SW24 (2 stron) w kategorii toaleta. Ta instrukcja była pomocna dla 12 osób i została oceniona przez 6.5 użytkowników na średnio 3.7 gwiazdek
Strona 1/2

Before installing the pump, remember the following:
1. Vacuum pump can be installed horizontally (either right-side
up A
or upside down B
), or vertically with inlet at bottom C
.
2. The pump can be mounted from 2 to 15 feet from the vacuum
tank. The maximum distance is 15 feet.
3. Install vacuum pump at same level or lower than vacuum tank
outlet. Do not install pump higher than the vacuum tank outlet.
4. The maximum head pressure on the discharge of the pump must
not exceed 6 feet.
Note: Two-toilet systems require a vacuum pump and vacuum tank for each toilet.
It provides the benet of a totally redundant operating toilet in case of failure in one
toilet. Two pumps greatly reduce hose runs and system complexity.
Installing the pump:
1. Make sure the vacuum pump is properly located before proceeding. Place the vacuum pump on the surface
to be mounted. Position as needed. Using a center punch, mark the four slotted holes in the pump feet.
Remove pump.
2. Using a 3/16-inch drill bit, drill the four mounting holes. Use a #14 wood screw to secure pump.
3. The ow direction is indicated on the pump body.
Stainless steel wall mounting bracket is available as optional accessory – P/N 341505.
Wiring the pump:
Wire the S-series pump as shown in the wiring diagram. Use multistranded copper wire. Proper fuse or circuit
breaker size is extremely important for pump and wire protection (see chart above). Overfusing this pump will
result in warranty invalidation.
Electrical schematic also shows installation of optional “night
switch”.
Dimensional
Specications
Electrical
Specications
S Vacuum Pump with
W Motor
Installation Instructions
IMPORTANT NOTICE
VacuFlush
®
sanitation systems must be installed according to
Dometic’s recommended procedures. Do not attempt installation without rst contacting a SeaLand
Product certied dealer or Dometic Corporation.
Model Volts (DC) Avg. Amp Draw GPH Fuse/Breaker Wire Size Weight
SW12 12 6 230 10 amps 12-14 ga. 8 lbs.
SW24 24 3 230 5 amps 14-16 ga. 8 lbs.
A
B C
Dometic Corporation, Sanitation Division
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611 USA
1-800-321-9886 • Fax: 330-496-3097
www.Dometic.com
Specyfikacje produktu
| Marka: | Dometic |
| Kategoria: | toaleta |
| Model: | Pump SW24 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Dometic Pump SW24, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje toaleta Dometic
19 Grudnia 2024
5 Października 2024
5 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
4 Października 2024
3 Października 2024
Instrukcje toaleta
- ProFlo
- Curaqua
- AXA
- SereneLife
- Kogan
- La Playa
- TMC
- Sanyo
- Coleman
- Schütte
- TOTO
- Villeroy And Boch
- PolyJohn
- Philips
- Jabsco
Najnowsze instrukcje dla toaleta
7 Kwietnia 2025
7 Kwietnia 2025
30 Marca 2025
29 Marca 2025
29 Marca 2025
29 Marca 2025
29 Marca 2025
28 Marca 2025
28 Marca 2025
27 Marca 2025