Introduction 
Congratulations on your purchase of the Extech model 38073 Analog Multimeter. 
This device measures AC/DC Voltage, DC Current, Resistance, dB, and has battery 
test, displaying measurements in analog format. Properly used, this meter will 
provide many years of reliable service. 
Safety 
International Safety Symbols 
This symbol, adjacent to another symbol or terminal, indicates the user 
must refer to the manual for further information. 
This symbol, adjacent to a terminal, indicates that, under normal use, 
hazardous voltages may be present 
Double insulation 
WARNINGS 
1.  When measuring voltage, ensure that the function switch is not in the current or 
resistance positions. Before taking any measurement ensure that the function 
switch is set to the appropriate position. 
2.  Use great care taking measurements when the voltages are greater than 25VAC 
rms or 35VDC. These voltages are considered a shock hazard. 
3.  When taking current measurements ensure that the circuit under test is not "live". 
Remove power to the circuit, apply the test leads, and then power the circuit. 
4.  For resistance measurements, ensure that the circuit or component is de-
energized. 
5.  Use care when measuring current transformers, high voltage may result at the 
meter's terminals if an open circuit exists. 
6.  Ensure that the test leads are in good repair before each use. Have the meter 
serviced if it appears that the test leads are damaged. 
7.  Do not exceed the measurement range limits specified by the manufacturer. 
8.  Replace fuse with fuse of the same rating only. 
9.  Before opening the case to replace battery or fuse, disconnect the test leads from 
any circuit or component under test and turn the function switch to the OFF 
position. 
A UL mark does not indicate that this product has been evaluated for the accuracy of 
its readings. 
Specifications 
  Range  Accuracy  Sensitivity 
DC Voltage  2.5, 10, 50, 250, 300V  ± 5% of full scale  2KΩ / Volt sensitivity 
AC Voltage  10, 50, 300V  ± 5% of full scale  2KΩ / Volt sensitivity 
DC Current  0.5, 10, 250mA  ± 5% of full scale   
Resistance  Rx10, Rx1000 (Rx1k)  ± 5% of full scale   
Decibels  -10 to 56 dB    (0dB = 1mW 
dissipated in 600Ω) 
1.5V  ± 10% of full scale  Load current: 125mA Battery Test 
9V  ± 10% of full scale  Load current: 10mA 
Display type  Analog Continuous 
Operating Temp.  41 to 104oF (5 to 40oC) 
Storage Temp  41 to 104oF (5 to 40oC) 
Battery  One 1.5V AA battery 
Battery life  10 hours  (continuous) 
Fuses  500mA, 250V fast acting 
Dimensions/Weight  3.5x6.1x1.9" (88x155x49mm) / 10.2 oz. (288g) approx. 
Safety  For indoor use and in accordance with Overvoltage 
Category II, Pollution Degree 2. Category II includes local 
level, appliance, portable equipment, etc., with transient 
overvoltages less than Overvoltage Category III. 
Meter Description 
1.  Analog Display 
2.  Display zero adjust 
3.  0Ω adjust 
4.  Function select switch 
5.  Test Leads 
Operation 
NOTICE: Read and understand all warning statements listed in the safety 
section of this operation manual prior to using this meter. 
AC/DC Voltage Measurements  
1.  Set the function switch to the desired voltage range position. If the range of the 
measurement is not known beforehand, select the highest range first and then 
work down range by range. 
2.  Connect the test leads in parallel to the circuit under test. 
3.  Read the voltage measurement on the analog display. 
DC mA Current Measurements 
1.  For mA current measurements set the function switch to the desired current range 
position and insert the red test lead into the mA terminal. If the range of the 
measurement is not known beforehand, select the highest range first and work 
down range by range as needed. 
2.  Remove power from the circuit under test and open the circuit at the point where 
you wish to measure current. 
3.  Touch the black test probe tip to the negative side of the circuit and touch the red 
test probe tip to the positive side of the circuit. 
4.  Apply power to the circuit. 
5.  Read the current on the analog display. If the analog pointer fails to move during 
current measurements, check the meter’s internal fuse. 
Resistance Measurements 
1.  Set the function switch to the desired resistance range position. 
2.  Touch the test probe tips across the circuit or component under test. It is best to 
disconnect one side of the resistor under test so the rest of the circuit will not 
interfere with the resistance reading. 
3.  Read the resistance on the analog display.  
Battery Test 
1.  Select the 1.5V or 9V BAT position using the function select switch. 
2.  Connect the red test lead to the positive side of the 1.5V or 9V battery and the 
black test lead to the negative side of the 1.5V or 9V battery. 
3.  Read the analog display. The red display region indicates a weak (bad) battery, 
the green display region indicates a good battery, and the ? region indicates that 
the battery is on the verge of weakening. 
Decibel (dB) Measurements 
1.  Set the function switch to the desired AC Voltage position. 
2.  Connect the test leads across the circuit under test. 
3.  For the 10V AC range, read dB directly from the analog scale. 
4.  For other ranges, calculate the measurement using the table below: 
5.  Circuits with dc component, require a capacitor between test leads and circuit. 
dB Range  -10 to 22dB  4 to 36 dB  24 to 56 dB 
AC Range  10V  50V  500V 
Add value to reading  0  14  34 
Maintenance 
WARNING: To avoid electrical shock, disconnect the meter from any circuit, remove 
the  test  leads  from  the  input  terminals  and  turn  OFF the  meter  before  opening  the 
case. Do not operate with open case. Install only the same type of fuse or equivalent 
Cleaning and Storage 
Periodically wipe the case with a damp cloth and mild detergent; do not use 
abrasives or solvents. If the meter is not to be used for periods of longer than 60 
days, remove the battery and store it separately 
Battery and Fuse replacement 
1.  Remove the meter's protective holster 
2.  Remove the three rear Phillips head screws and open the meter case. 
3.  Replace the AA battery and/or fuse (500mA @250V, fast acting) 
4.  Re-assemble the meter 
Warranty 
EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of 
defects in parts and workmanship for one year from date of shipment (a six month 
limited warranty applies on sensors and cables). If it should become necessary to 
return the instrument for service during or beyond the warranty period, contact the 
Customer Service Department at (781) 890-7440 ext. 210 for authorization. A Return 
Authorization (RA) number must be issued before any product is returned to 
Extech. The sender is responsible for shipping charges, freight, insurance and 
proper packaging to prevent damage in transit. This warranty does not apply to 
defects resulting from action of the user such as misuse, improper wiring, operation 
outside of specification, improper maintenance or repair, or unauthorized 
modification. Extech specifically disclaims any implied warranties or merchantability 
or fitness for a specific purpose and will not be liable for any direct, indirect, incidental 
or consequential damages. Extech's total liability is limited to repair or replacement of 
the product. The warranty set forth above is inclusive and no other warranty, whether 
written or oral, is expressed or implied. 
Repair and Calibration Services 
Extech offers complete repair and calibration services for all Extech products. 
For periodic calibration, NIST certification or repair of any Extech product, call 
customer service for details on services available. Extech recommends that 
calibration be performed on an annual basis to insure calibration integrity. 
Copyright © 2000 Extech Instruments Corporation. All rights reserved 
including the right of reproduction in whole or in part in any form. 
38073   V1.3     9/00 
Specyfikacje produktu
| Marka: | Extech | 
| Kategoria: | multimetr | 
| Model: | 38073 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Extech 38073, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Extech
                        
                         22 Grudnia 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         19 Września 2024
                        
                    
                                                            
                        
                         18 Września 2024
                        
                    
                                                            
                        
                         14 Września 2024
                        
                    
                                                            
                        
                         14 Września 2024
                        
                    
                                                            Instrukcje multimetr
- Milwaukee
- Emos
- Yato
- Brennenstuhl
- Pyle
- Monacor
- Workzone
- Plieger
- PCE Instruments
- Wago
- Wiha
- Testboy
- Hager
- Multimetrix
- Topcraft
Najnowsze instrukcje dla multimetr
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         26 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025