Instrukcja obsล‚ugi Extech 45160


Przeczytaj poniลผej ๐Ÿ“– instrukcjฤ™ obsล‚ugi w jฤ™zyku polskim dla Extech 45160 (4 stron) w kategorii Sprzฤ™t pomiarowy. Ta instrukcja byล‚a pomocna dla 14 osรณb i zostaล‚a oceniona przez 7.5 uลผytkownikรณw na ล›rednio 4.6 gwiazdek

Strona 1/4
USER๎˜ƒMANUAL๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
3 1โ€inโ€ ๎˜ƒHumidity,๎˜ƒTemperature๎˜ƒand๎˜ƒAirflow๎˜ƒMeter๎˜ƒ
๎˜ƒ
๎˜ƒ
Model๎˜ƒ45160๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
๎˜ƒ
45160-en-GB_v1.6 11/16 2
Introduction๎˜ƒ
Congratulations๎˜ƒon of๎˜ƒyour๎˜ƒpurchase๎˜ƒ ๎˜ƒ the๎˜ƒExtech๎˜ƒModel๎˜ƒ45160๎˜ƒ โ€3 inโ€ ๎˜ƒ1 Humidity,๎˜ƒ
Temperature Airflow๎˜ƒand๎˜ƒ ๎˜ƒ Meter.๎˜ƒThe๎˜ƒdual and๎˜ƒdisplay๎˜ƒindicates๎˜ƒAir๎˜ƒVelocity๎˜ƒ ๎˜ƒ
Temperature Temperature.๎˜ƒor๎˜ƒHumidity๎˜ƒand๎˜ƒ ๎˜ƒ
๎˜ƒ
This๎˜ƒdevice๎˜ƒis tested๎˜ƒshipped๎˜ƒfully๎˜ƒ ๎˜ƒ and๎˜ƒcalibrated๎˜ƒand,๎˜ƒwith๎˜ƒproper๎˜ƒuse,๎˜ƒwill๎˜ƒprovide๎˜ƒ
years๎˜ƒof reliable๎˜ƒ ๎˜ƒservice.๎˜ƒPlease๎˜ƒvisit๎˜ƒour๎˜ƒwebsite (www.extech.com)๎˜ƒ ๎˜ƒto๎˜ƒcheck๎˜ƒfor๎˜ƒthe๎˜ƒ
latest User Updates,๎˜ƒversion๎˜ƒof๎˜ƒthis๎˜ƒ ๎˜ƒ Manual,๎˜ƒProduct๎˜ƒ ๎˜ƒ Product๎˜ƒRegistration,๎˜ƒand๎˜ƒ
Customer๎˜ƒSupport.๎˜ƒ
๎˜ƒ
Specifications๎˜ƒ
Range๎˜ƒSpecifications๎˜ƒ
Measurement Range Resolution Accuracy
MPH (Miles per hour) 0.9 to 67.0MPH 0.1MPH ๏€ 
๏‚ฃ๏€ 3937 ft/min: ยฑ3% F.S.
> 3937 ft/min: ยฑ4% F.S
km/hr (kilometers per hour) 1.4 to 108.0 km/h 0.1km/h
Knots (nautical miles per hour)
0.8 to 58.3 knots 0.1knots
m/sec (meters per second) 0.40 to 30.00 m/s 0.1 m/s
ft/min (feet per minute) 80 to 5910 ft/min 1ft/min
Temperature/Thermistor 32 to 122oF (0 to 50oC) 0.1oF/C ยฑ 2.5oF (ยฑ 1.2oC)
Temperature /Thermocouple -148 to 2372ยฐF
-100 to 1300ยฐC
0.1ยฐF
0.1ยฐC
ยฑ (1% + 2ยฐF)
ยฑ (1% + 1ยฐC)
Relative Humidity 10.0 to 95.0% 0.1% ยฑ4% RH (from 10% to 70%RH)
๏€ ยฑ5.2% RH (> 70% RH)
General๎˜ƒSpecifications๎˜ƒ
Display 4 digit (9999 count) Dual Display LCD
Sensors Thin film capacitance humidity sensor
Min/Max Min/Max recalls the highest/lowest reading
Data Hold Data Hold freezes the display
Operating conditions 0 to 50oC (32 to 122oF) / < 80% RH
Power supply 9 Volt Battery
Dimensions / Weight Instrument: 156 x 60 x 33mm (6.14 x 2.36 x 1.29โ€)
Vane: 24mm (1โ€) diameter / 95 g (3 oz.)
45160-en-GB_v1.6 11/16 3
Meter๎˜ƒDescription๎˜ƒ
1. LCD๎˜ƒdisplay๎˜ƒ
2. Keypad๎˜ƒ
3. Vane๎˜ƒ
4. Thermocouple๎˜ƒinput๎˜ƒjack๎˜ƒ
5. %RH๎˜ƒsensor๎˜ƒ
6.๎˜ƒBattery๎˜ƒcompartment๎˜ƒ(rear)๎˜ƒ
Operation๎˜ƒ
Turn๎˜ƒPower๎˜ƒON๎˜ƒ
Press๎˜ƒthe button๎˜ƒpower๎˜ƒ ๎˜ƒto๎˜ƒturn๎˜ƒpower test.๎˜ƒon.๎˜ƒThe๎˜ƒmeter๎˜ƒwill๎˜ƒperform๎˜ƒ ๎˜ƒa short๎˜ƒselfโ€ ๎˜ƒ
A. Airflow๎˜ƒMeasurements๎˜ƒ
1. Press๎˜ƒthe the๎˜ƒ ๎˜ƒFunction button๎˜ƒto๎˜ƒselect๎˜ƒ ๎˜ƒAnemometer function.๎˜ƒ ๎˜ƒIn๎˜ƒAir๎˜ƒ
Flow show๎˜ƒmode,๎˜ƒthe will๎˜ƒdisplay๎˜ƒ ๎˜ƒ ๎˜ƒAir๎˜ƒVelocity๎˜ƒand๎˜ƒTemperature.๎˜ƒ
2. Press๎˜ƒ ๎˜ƒUnit button๎˜ƒto๎˜ƒselect๎˜ƒdesired๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒunit of measure (FPM, MPH,
KNOT,๎˜ƒKM/H,๎˜ƒor๎˜ƒM/S)๎˜ƒ
B. %RH๎˜ƒMeasurements๎˜ƒ
1. Press๎˜ƒthe๎˜ƒ ๎˜ƒFunction button mode,๎˜ƒto๎˜ƒselect๎˜ƒ%RH๎˜ƒfunction.๎˜ƒIn๎˜ƒ%RH๎˜ƒ ๎˜ƒthe๎˜ƒ
display๎˜ƒwill๎˜ƒshow๎˜ƒ%RH๎˜ƒand๎˜ƒTemperature.๎˜ƒ
2. Press๎˜ƒthe button๎˜ƒ ๎˜ƒยฐC/ยฐF ๎˜ƒto๎˜ƒselect๎˜ƒthe๎˜ƒdesired๎˜ƒtemperature๎˜ƒunit๎˜ƒof๎˜ƒ
measure.๎˜ƒ
C. Temperature๎˜ƒMeasurements๎˜ƒ
1. Press๎˜ƒthe๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒ ๎˜ƒFunction button to select the Temperature function. In
Temperature mode,๎˜ƒ ๎˜ƒthe๎˜ƒdisplay๎˜ƒwill๎˜ƒshow๎˜ƒonly๎˜ƒ ๎˜ƒtemperature.
2. Plug๎˜ƒthe the๎˜ƒthermocouple๎˜ƒinto๎˜ƒ ๎˜ƒmeter's๎˜ƒthermocouple๎˜ƒinput๎˜ƒjack.๎˜ƒIf๎˜ƒ
no๎˜ƒthermocouple๎˜ƒis๎˜ƒconnected,๎˜ƒor๎˜ƒif is๎˜ƒthe๎˜ƒthermocouple๎˜ƒ ๎˜ƒdefective,๎˜ƒ
the๎˜ƒmeter๎˜ƒwill๎˜ƒdisplay๎˜ƒโ€˜โ€โ€โ€โ€โ€โ€˜.๎˜ƒ(Primary๎˜ƒdisplay๎˜ƒtemperature๎˜ƒwill๎˜ƒonly๎˜ƒ
work๎˜ƒif is๎˜ƒ ๎˜ƒa thermocouple๎˜ƒ ๎˜ƒconnected).๎˜ƒ
3
45
1
2
6


Specyfikacje produktu

Marka: Extech
Kategoria: Sprzฤ™t pomiarowy
Model: 45160

Potrzebujesz pomocy?

Jeล›li potrzebujesz pomocy z Extech 45160, zadaj pytanie poniลผej, a inni uลผytkownicy Ci odpowiedzฤ