Instrukcja obsługi Extech MN36
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Extech MN36 (2 stron) w kategorii multimetr. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 6 użytkowników na średnio 4.4 gwiazdek
                        Strona 1/2
                    
                    
                    
MN36- -US_V2.3   10/20 en
Safety 
This symbol, adjacent to another symbol or terminal, indicates 
the user must refer to the manual for further information. 
This symbol, adjacent to a terminal, indicates that, under 
normal use, hazardous voltages may be present 
Double insulation 
1.  Improper use of this meter can cause damage, shock, injury or death. 
Read and understand this user manual before operating the meter. 
2.  Make sure any covers or battery doors are properly closed and ured. 
3.  Always remove the test leads before replacing the battery or fuses. 
4.  Inspect the condition of the test leads and the meter itself for any 
damage before operating the meter. Repair any damage before use. 
5.  Do not exceed the maximum rated input limits. 
6.  Use great care when making measurements if the voltages are 
greater than 25VAC rms or 35VDC. These voltages are considered a 
shock hazard. 
7.  Always discharge capacitors and remove power from the device 
under test before performing Diode, Resistance or Continuity tests. 
8.  Remove the battery from the meter if the meter is to be stored for 
long periods. 
9.  To avoid electric shock, do not measure AC current on any circuit 
whose voltage exceeds 250V AC. 
Input Limits 
Function 
Maximum Input 
VDC, VAC 
600V AC/600V   AC
Resistance, Diode, Continuity 
500V DC/AC 
mA DC 
200mA DC 
10A   DC
10A DC (15 seconds max. 
every 15 min.) 
Frequency 
250V DC/AC 
Two-year Warranty 
FLIR Systems, Inc. warrants this Extech brand instrument   to be free 
of defects in parts and workmanship for   from date of two years
shipment (a six-month limited warranty applies to sensors and cables). 
To view the full warranty text please visit: 
http://www.extech.com/support/warranties. 
Calibration and Repair Services 
FLIR Systems, Inc. oers calibration and repair services  r the fo
Extech brand products we sell. We oer NIST traceable calibration for 
most of our products. Contact us for information on calibration and repair 
availability, refer to the contact information below. Annual calibrations 
should be performed to verify meter performance and accuracy. Product 
specications are subject to change without notice. Please visit our 
website for the most up- -date product information:  . to www.extech.com
Contact Customer Support 
Customer Support Telephone List:   https://support.ir.com/contact
Calibration, Repair and Returns,  : repair@extech.com 
Technical Support:   https://support.ir.com
Copyright   2004-2020 FLIR Systems, Inc. ©
All rights reserved including the right of reproduction in whole or in part 
in any form 
www.extech.com 
User Manual 
MiniTecTM Series  
Model MN36 
Auto-Ranging Mini MultiMeter 
Introduction 
Congratulations o  Auto-Ranging n your purchase of Extech’s MN36
Multimeter. This meter measures AC/DC Voltage, AC/DC Current, 
Resistance, Capacitance, Frequency, Temperature, Diode Test and 
Continuity. Proper use and care of this meter will provide many years of 
reliable service. 
Specications 
Accuracy  Stated at 73oF 10oF (23oC 5 oC) and less than 
70%   RH
Diode Test  Test current of 0.6mA maximum, open circuit 
voltage 1.5V DC typical 
Continuity Check  Audible signal will sound if the resistance is less 
than approximately <8   
Temperature sensor Requires type K thermocouple 
Input Impedance  10M    AC/ ) (V DC
Display  3999 count LCD 
Overrange    is displayed “OL”
Polarity  Automatic (no indication for positive polarity); 
Minus (-) sign for negative polarity. 
Measurement Rate  3 times per second, nominal 
Low Battery     “   ” is displayed if battery voltage drops below 
operating voltage 
Batteries    Requires (2) AAA batteries
Fuses   mA range; 250mA/250V fast blow 
 10A range, no protection 
Operating Temp  32oF to 104o
F (0 oC to 40oC) 
Storage Temp  -4o
F to 140 o
F (-20 o
C to 60 oC) 
Relative Humidity  Maximum relative humidity 80% for temperatures 
up to 31 C decreasing linearly to 50% relative °
humidity at 40  °C.
Operating Altitude  7000ft (2000 meters) maximum 
Weight   5.4 oz. (153g). 
Size   138mm x 72mm x 38mm) 5.43” x 2.83” x 1.5” (
Safety  For indoor use and in accordance with 
Overvoltage Category II, Pollution Degree 2. 
Category II includes local level, appliance, 
portable equipment, etc., with transient 
overvoltages less than Overvoltage Category III 
Specications 
Function 
Range 
Accuracy 
DC Voltage  
(V DC) 
4  00.0mV
(0.5% reading + 4 digits) 
4.000V 
(0.8% reading + 4 digits) 
40.00V 
400.0V 
600V 
AC Voltage  
(V AC) 
50-60Hz 
40-400Hz 
4.000V 
(0.8% rdg + 4 d) 
(2% rdg + 5 d) 
40.00V 
(1.2% rdg + 5 d) 
400.0V 
600V 
DC Current  
400.0µA 
(1.2% reading + 4 digits) 
4000µA 
40.00mA 
200.0mA 
10A 
(2.5% reading + 4 digits) 
AC Current 
(40 to 400Hz) 
400.0µA 
(1.5% reading + 5 digits) 
4000µA 
40.00mA 
200.0mA 
10A 
(3% reading + 5 digits) 
Resistance 
4  00.0
(1.2% reading + 4 digits) 
4.000k  
40.00k  
4 k  00.0 
4.000M  
20.00M  
(3.0% reading + 5 digits) 
Capacitance 
4.000nF 
Not specied 
40.00nF 
(3.0% reading +   digits) 10
400.0nF 
4.000µF 
40.00µF 
Not Specied 
100µF 
Frequency 
10.00Hz 
(1.0% reading + 4 digits) 
10Hz to 1MHz 
Sensitivity: 5.0Vrms  
100Hz 
1.000kHz 
10.00kHz 
100.0kHz 
1.000MHz 
5.000MHz 
Not specied 
Temp  F 
Temp  C 
-40 to 
1400 F 
-20 to 750 C 
-40 to 650°F;  (1.0% rdg +   digits) 10
651 00 10 to 14 °F;  (3% rdg +  digits) 
-20 to 400 C;  (1.0% rdg +   digits)   10
400 to 750 C;  (3% rdg +   digits)   10
(probe accuracy not included) 
Specyfikacje produktu
| Marka: | Extech | 
| Kategoria: | multimetr | 
| Model: | MN36 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Extech MN36, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje multimetr Extech
                        
                         22 Grudnia 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         24 Września 2024
                        
                    
                                                            
                        
                         19 Września 2024
                        
                    
                                                            
                        
                         18 Września 2024
                        
                    
                                                            
                        
                         14 Września 2024
                        
                    
                                                            
                        
                         14 Września 2024
                        
                    
                                                            Instrukcje multimetr
- PeakTech
- Etekcity
- Pyle
- HT Instruments
- Wiha
- TFA
- Brandson
- Sanwa
- Kyoritsu
- Laserliner
- Qian
- Caltek
- Owon
- Micronta
- PCE Instruments
Najnowsze instrukcje dla multimetr
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         28 Marca 2025
                        
                    
                                                            
                        
                         26 Marca 2025
                        
                    
                                                            
                        
                         14 Marca 2025