Model information
Air
Air
Symbol ValueUnitSymbol ValueUnit
Prated,c 15.1 kWηs,c 215.8 %
Pdc15.10kW EERd2.72 䇷
Pdc11.13kW EERd4.63 䇷
Pdc7.15kW EERd6.17 䇷
Pdc 4.79kWEERd9.79 䇷
Cdc 0.25 䇷―――
POFF 0.010 kWPCK 0.023 kW
PTO 0.023 kWPSB 0.010 kW
Prated,h 15.1 kWηs,h 156.6 %
Pdh10.44kW COP
d2.37 䇷
Pdh6.35kW COP
d3.62 䇷
Pdh4.08kW COP
d6.35 䇷
Pdh3.88kW COP
d8.10 䇷
Pdh10.44kW COP
d2.37 䇷
Pdh7.97kW COP
d2.01 䇷
Tbiv -7 °C
Cdh 0.25 䇷
POFF 0.017 kWelbu1.93kW
PTO 0.040 kW
PCK 0.023 kWPSB 0.017 kW
2088
kg CO2eq
(100 years)
Cooling LWA 52.0 / 70.0dBCooling4400 m³/h
Heating LWA 52.0 / 70.0dBHeating4400 m³/h
Declared cooling capacity for part load at given outdoor
temperatures Tj and indoor 27°/19 °C (dry/wet bulb)
Declared energy efficiency ratio for part load at given outdoor
temperatures Tj
[1] Information sheet (Lot.21)
[2] This information includes the results of calculation of the seasonal energy consumption and efficiency for air conditioner in regards
to ErP pursuant to the Commission Regulation(EU) 2016/2281.
Outdoor unit / Indoor unit
Outdoor side heat exchanger of air conditioner
Indoor side heat exchanger of air conditioner
Compressor type / driver of compressor
Vapour compression / Electric motor
Cooling
Item
Item
Rated cooling capacity
Seasonal space cooling energy
efficiency
AJ*054LCLDH / AUXB012GLEH ×3 + AUXB014GLEH ×1
Tj = + 35 ºC
Tj = + 35 ºC
Tj = + 30 °C
Tj = + 30 ºC
Tj = + 25 °C
Tj = + 25 ºC
Declared heating capacity for part load at indoor temperature
20 °C and outdoor temperature Tj
Declared coefficient of performance for part load at given
outdoor temperatures Tj
Tj = + 20 °C
Tj = + 20 ºC
Degradation co-efficient for air
conditioners
―
Power consumption in modes other than ‘active mode’
Off mode
Crankcase heater mode
Thermostat-off mode
Standby mode
Heating
Rated heating capacity
Seasonal space heating energy
efficiency
Tj = – 7 °C
Tj = – 7 °C
Tj = + 2 °C
Tj = + 2 °C
Tj = + 7 °C
Tj = + 7 °C
Tj = + 12 °C
Tj = + 12 °C
Tbiv = bivalent temperature
Tbiv = bivalent temperature
TOL = operation limit
TOL = operation limit
Bivalent temperature
䇷
䇷
䇷
䇷
Degradation co-efficient heat
pumps
Power consumption in modes other than ‘active mode’
Supplementary heater
Off mode
Back-up heating capacity
Thermostat-off mode
Type of energy input
Electricity
FUJITSU GENERAL LIMITED
3-3-17,Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan
* Please refer to the last page for translation to other languages.
PART No. 9384138828-01
Crankcase heater mode
Standby mode
Other items
Capacity control
Variable
Air flow rate,
outdoor measured
GWP of the refrigerant
Sound power level
(Indoor unit /
Outdoor unit)
Contact details
V20170928
Specyfikacje produktu
| Marka: | Fujitsu |
| Kategoria: | klimatyzacja |
| Model: | AJH054LCLDH |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Fujitsu AJH054LCLDH, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje klimatyzacja Fujitsu
3 Kwietnia 2025
30 Marca 2025
24 Lutego 2025
24 Lutego 2025
24 Lutego 2025
24 Lutego 2025
24 Lutego 2025
9 Stycznia 2025
9 Stycznia 2025
9 Stycznia 2025
Instrukcje klimatyzacja
Najnowsze instrukcje dla klimatyzacja
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025