Instrukcja obsługi Fujitsu ASMG30CMTA
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Fujitsu ASMG30CMTA (14 stron) w kategorii Rozłupnik. Ta instrukcja była pomocna dla 17 osób i została oceniona przez 9 użytkowników na średnio 4.9 gwiazdek
                        Strona 1/14
                    
                    
                    
En-1
1.  SAFETY PRECAUTIONS
•  Read carefully all of safety information written in this manual before you install or use 
the air conditioner.
•  The warnings and precautions indicated in this manual contain important information 
pertaining to your safety. Be sure to observe them.
•  
Hand this manual, together with the operating manual, to the customer. Request the cus-
tomer to keep them on hand for future use, such as for relocating or repairing the unit.
 WARNING
Indicates a potentially or imminently hazardous situation 
which, if not avoided, could result in death or serious injury. 
 CAUTION
Indicates a potentially hazardous situation that may result in 
minor or moderate injury or damage to property.
 WARNING
•  The appliance, outlet and inlet shall be installed, operated and stored in a room with a 
fl oor area larger than X m2.
Minimum installation space
30 model M (kg) M ≤ 1.65 1.65 < M ≤ 2.05 2.05 < M ≤ 2.45 2.45 < M ≤ 2.85
X (m2) 2.60 4.01 5.72 7.74
M (kg): Amount of refrigerant charge  ( IEC 60335-2-40 )
X (m
2): Minimum room area
•  To avoid getting an electric shock, never touch the electrical components soon after 
the power supply has been turned off . After turning off  the power, always wait 10 
minutes or more before you touch the electrical components.
•  Installation of this product must be done by experienced service technicians or profes-
sional installers only in accordance with this manual. Installation by non-professional 
or improper installation of the product might cause serious accidents such as injury, 
water leakage, electric shock, or fi re. If the product is installed in disregard of the 
instructions in this manual, it will void the manufacturer’s warranty.
•  Do not turn on the power until all work has been completed. Turning on the power be-
fore the work is completed can cause serious accidents such as electric shock or fi re.
•  If refrigerant leaks when you are working, ventilate the area. If the leaking refrigerant 
is exposed to a direct fl ame, it may produce a toxic gas.
•  Installation must be performed in accordance with regulations, codes, or  standards for 
electrical wiring and equipment in each country, region, or the installation place.
•  Do not use this equipment with air or any other unspecifi ed refrigerant in the refriger-
ant lines. Excess pressure can cause a rupture.
•  During installation, make sure that the refrigerant pipe is attached fi rmly before you 
run the compressor. Do not operate the compressor under the condition of refrigerant 
piping not attached properly with 2-way or 3-way valve open. This may cause abnor-
mal pressure in the refrigeration cycle that leads to rupture and even injury.
•  When installing or relocating the air conditioner, do not mix gases other than the speci-
fi ed refrigerant (R32) to enter the refrigerant cycle.
If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to 
an abnormally high value and cause rupture, injury, etc.
• For appropriate working of the air conditioner, install it as written in this manual.
• To connect indoor unit and outdoor unit, or indoor unit and branch box, use air condi-
tioner piping and cables available through your local distributor. This manual describes 
proper connections using such installation set.
• Do not modify power cable, use extension cable or branch wiring. Improper use may
cause electric shock or fi re by poor connection, insuffi  cient insulation or over current.
• 
Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation.
• There is no extra refrigerant in the outdoor unit for air purging.
•  Do not use means to accelerate the defrosting process or to clean, other than those 
recommended by the manufacturer.
•  The appliance shall be stored in a room without continuously operating ignition 
sources (for example: open fl ames, an operating gas appliance or an operating 
electric heater).
•  Do not pierce or burn.
•  Be aware that refrigerants may not contain an odour.
•  Using the same vacuum pump for diff erent refrigerants may damage the vacuum 
pump or the unit.
• Use a clean gauge manifold, vacuum pump and charging hose for R32 or R410A
exclusively.
•  Do not modify this unit, such as opening a hole in the cabinet. 
•  During the pump-down operation, make sure that the compressor is turned off  before 
you remove the refrigerant piping.
Do not remove the connection pipe while the compressor is in operation with 2 way or 
3 way valve open. This may cause abnormal pressure in the refrigeration cycle that 
leads to rupture and even injury.
 CAUTION
•  Read carefully all safety information written in this manual before you install or use 
the air conditioner.
•  This unit must be installed by qualifi ed personnel with a capacity certifi cation of han-
dling refrigerant fl uids. Refer to regulation and laws in use on installation place.
•  Install the unit by following local codes and regulations in force at the place of instal-
lation, and the instructions provided by the manufacturer.
•  This unit is part of a set constituting an air conditioner. The unit must not be installed 
alone or be installed with non-authorized device by the manufacturer.
•  When installing pipes shorter than 3 m, sound of the outdoor unit will be transferred 
to the indoor unit, which will cause large operating sound or some abnormal sound.
•  Always use a separate power supply line protected by a circuit breaker operating on 
all wires with a distance between contact of 3 mm for this product.
•  To protect the persons, earth (ground) the product correctly, and use the power cable 
combined with an Earth Leakage Circuit Breaker (ELCB).
•  This units are not explosion proof, and therefore should not be installed in explosive 
atmosphere.
•  This unit contains no user-serviceable parts. Always consult experienced service 
technicians for repairing.
•  When moving or relocating the air conditioner, consult experienced service techni-
cians for disconnection and reinstallation of the unit.
•  Children should be monitored to ensure they do not play with the device.
•  This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, un-
less they have been given supervision or instruction concerning use of the appliance 
by a person responsible for their safety. Children should be supervised to ensure 
that they do not play with the appliance.
•  Do not touch the aluminum fi ns of heat exchanger built-in the indoor or outdoor unit 
to avoid personal injury when you install or maintain the unit.
•  Do not place any other electrical products or household belongings under the indoor 
unit or outdoor unit. Condensation dripping from the unit might get them wet, and 
may cause damage or malfunction to the property.
•  Be careful not to scratch the air conditioner when handling it.
•  After installation, explain correct operation to the customer, using the operating manual.
Precautions for using R32 refrigerant
The basic installation work procedures are the same as conventional refrigerant (R410A, 
R22) models. However, pay careful attention to the following points:
 WARNING
Since the working pressure is 1.6 times higher than that of refrigerant R22 models, 
some of the piping and installation and service tools are special. (See “2.1. Special 
tools for R32 (R410A)”.)
Especially, when replacing a refrigerant R22 model with a new refrigerant R32 model, 
always replace the conventional piping and fl are nuts with the  R410A piping and R32 and 
fl are nuts on the outdoor unit side. 
For R32 and R410A, the same fl are nut on the outdoor unit side and pipe can be used.
AIR CONDITIONER
Wall Mounted Type
INSTALLATION MANUAL
Contents
1.  SAFETY PRECAUTIONS .................................................................. 1
2.  ABOUT THIS PRODUCT................................................................... 3
3.  GENERAL SPECIFICATION ............................................................. 4
4.  ELECTRICAL REQUIREMENT ......................................................... 4
5.  SELECTING THE MOUNTING POSITION ....................................... 4
6.  INSTALLATION WORK ..................................................................... 5
7.  ELECTRICAL WIRING  ..................................................................... 7
8.  FINISHING ........................................................................................ 7
9.  FRONT PANEL REMOVAL AND INSTALLATION ............................. 8
10.  TEST RUN ......................................................................................... 8
11.   REMOTE CONTROLLER INSTALLATION ........................................ 8
12.  OPTIONAL KIT INSTALLATION ........................................................ 9
13.  INSTALLATION WORK (option) ...................................................... 10
14.  SPECIAL INSTALLATION METHODS ............................................. 10
15.  REMOTE CONTROLLER CUSTOM CODE SETTING ....................11
16.  FUNCTION SETTING.......................................................................11
17.  CUSTOMER GUIDANCE ................................................................ 13
18.  ERROR CODES .............................................................................. 13
PART No. 9387082173-03
For authorized service personnel only.
R32
R32.
ไทย  English
Specyfikacje produktu
| Marka: | Fujitsu | 
| Kategoria: | Rozłupnik | 
| Model: | ASMG30CMTA | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Fujitsu ASMG30CMTA, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Rozłupnik Fujitsu
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024
                        
                    
                                                            
                        
                         3 Października 2024
                        
                    
                                                            
                        
                         30 Września 2024
                        
                    
                                                            Instrukcje Rozłupnik
- Marmitek
- Akasa
- Rose Electronics
- Audio-Technica
- MuxLab
- Samsung
- IFM
- Klover
- CLUB3D
- Comprehensive
- D-Link
- Atlona
- InFocus
- Televés
- SmartAVI
Najnowsze instrukcje dla Rozłupnik
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         27 Marca 2025
                        
                    
                                                            
                        
                         20 Lutego 2025
                        
                    
                                                            
                        
                         12 Stycznia 2025
                        
                    
                                                            
                        
                         8 Stycznia 2025
                        
                    
                                                            
                        
                         8 Stycznia 2025
                        
                    
                                                            
                        
                         5 Stycznia 2025
                        
                    
                                                            
                        
                         1 Stycznia 2025
                        
                    
                                                            
                        
                         1 Stycznia 2025
                        
                    
                                                            
                        
                         1 Stycznia 2025