Owner’s Manual
For
Automatic Transfer Switch
150 - 200 Amp, Integrated Meter Transfer Switch, Service Entrance Rated
Model Number
Integrated Ringed Meter Transfer Switch
RXUW200A3 – 200A
RXUW150A3 – 150A
Upgradeable Integrated Ringless Meter Transfer Switch
RBU200A3 – 200A
RBU150A3 – 150A
G0074000 – RBU Transfer Switch Upgrade Kit
SAVE THIS MANUAL FOR FUTURE REFERENCE
®
MODEL NUMBER: _________________________
SERIAL NUMBER: _________________________
DATE PURCHASED:________________________
WWW.GENERAC.COM
1-888-GENERAC
(1-888-436-3722)

ii Automatic Transfer Switch Owner’s Manual
(000393a)
WARNING
CANCER AND REPRODUCTIVE HARM
www.P65Warnings.ca.gov.

Automatic Transfer Switch Owner’s Manual iii
Table of Contents
Section 1: Safety
Introduction ..........................................................1
Read This Manual Thoroughly ....................................1
Safety Rules .........................................................1
Electrical Hazards ................................................2
General Hazards ..................................................3
Section 2: General Information
Unpacking ............................................................5
Contents in Loose Parts Bag ..............................5
Equipment Description .......................................5
Transfer Switch Mechanism (RXUW Models or RBU
with Upgrade Kit (G007400) Installed) ........................5
Utility Service Circuit Breaker ......................................6
Transfer Switch Data Decal ................................6
Transfer Switch Enclosure .................................6
Safe Use of Transfer Switch ...............................6
Load Management Options .................................7
Smart A/C Module (SACM) .........................................7
Application Considerations ..........................................7
Accessories ..........................................................8
Section 3: Installation
Introduction to Installation .................................9
Mounting ...............................................................9
Open Enclosure ...................................................9
Connecting Power Source
(RBU and RXUW) ...............................................10
Connecting Alternate Power Source
(RXUW Only) ......................................................10
Connecting Start Circuit Wires .........................13
Connecting SACM .............................................13
Control of Air Conditioner Load .................................13
Auxiliary Contact ...............................................13
Fault Current Label ............................................14
Install Upgrade Kit G0074000
(RBU Only) ..........................................................14
Section 4: Operation (RXUW Models and
Upgraded RBU with G007400 Kit Only)
Functional Tests and Adjustments .................. 15
Manual Operation .............................................. 15
Close to Utility Source Side .......................................15
Close to Generator Source Side ...............................16
Return to Utility Source Side .....................................16
Voltage Checks .................................................. 16
Utility Voltage Checks ...............................................16
Generator Voltage Checks ........................................16
Generator Tests Under Load ............................ 16
Checking Automatic Operation ........................ 17
Installation Summary ........................................ 17
Shutting Generator Down While Under Load or
During a Utility Outage ..................................... 17
Preparing for Maintenance ............................... 18
Testing The SACM ............................................. 18
SACM Fuse Service ........................................... 18
Section 5: Drawings and Diagrams
Installation Drawings—150-200A SER Meter
Main .................................................................... 19
Interconnection Drawings—Liquid-Cooled
Generator ........................................................... 20
Interconnection Drawings—Liquid-Cooled
Generator ........................................................... 21
Exploded View of RXUW Model ....................... 22
Exploded View of RXUW Model ....................... 23
Exploded View of RBU Model .......................... 26
Exploded View of RBU Model .......................... 27
Accessory KIT 200A XFRSW W SACM
G0074000 ............................................................ 30
Accessory Kit ATS Ring Cover G0074010 ...... 31
Accessory Kit Meter Jaw 5th Terminal
G0074020 ............................................................ 32
Accessory Kit Flash Shield G0074040 ............ 33
Accessory Kit Side Bus G0074050 .................. 34
Accessory Kit Pedestal 24 in. Extension
G0074060 ............................................................ 35
Specyfikacje produktu
Marka: | Generac |
Kategoria: | przełącznik |
Model: | RXUW150A3 |
Kolor produktu: | Black,White |
Wbudowany wyświetlacz: | Tak |
Częstotliwość wejściowa AC: | 50 - 60 Hz |
Wysokość produktu: | 215 mm |
Szerokość produktu: | 310 mm |
Głębokość produktu: | 161 mm |
Waga produktu: | 3600 g |
Szerokość opakowania: | 310 mm |
Wysokość opakowania: | 565 mm |
Głębokość opakowania: | 297 mm |
Certyfikat środowiskowy (zrównoważonego rozwoju): | RoHS,ENERGY STAR |
Port USB: | Tak |
Obsługiwane systemy operacyjne Windows: | Tak |
Typ ekranu: | LCD |
Długość przekątnej ekranu: | 8.4 " |
Zakres temperatur (eksploatacja): | 10 - 32.5 °C |
Zakres wilgotności względnej: | 20 - 80 % |
Ekran dotykowy: | Tak |
Pobór mocy w trybie czuwania: | 1 W |
Przewodowa sieć LAN: | Tak |
Pobór mocy: | 30 W |
Napięcie: | 100-240 V |
Głębokość koloru wejścia: | - bit |
Typ skanera: | Skaner z podajnikiem |
Typ zasilacza: | Prąd przemienny |
Rozmiary seri A ISO (A0…A9): | A4 |
Maksymalny rozmiar papieru ISO (seria A): | A4 |
Podwójne skanowanie: | Tak |
Optyczna rozdzielczość skanowania: | 600 x 600 DPI |
Skanuj do: | E-mail,Fax,File,FTP,USB |
Głębokość koloru wyjścia: | 24 bit |
Standardowe interfejsy: | Ethernet,USB 2.0 |
Wersja USB: | 2.0 |
Typ przetwornika obrazu: | CMOS CIS |
Maksymalny format skanowania: | 216 x 1000 mm |
Skanowanie w kolorze: | Tak |
Maksymalny dzienny cykl pracy: | 3000 stron(y) |
Standardowa pojemność podajnika (arkusze): | 50 ark. |
MInimalna grubość nośnika: | . mm |
Źródło światła: | RGB LED |
List: | Tak |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Generac RXUW150A3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje przełącznik Generac
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
8 Października 2024
Instrukcje przełącznik
- przełącznik Aeon Labs
- przełącznik Lindy
- przełącznik Brilliant
- przełącznik GAO
- przełącznik Tripp Lite
- przełącznik AMX
- przełącznik Alcatel
- przełącznik Alecto
- przełącznik Eberle
- przełącznik Vemer
- przełącznik KanexPro
- przełącznik Inverto
- przełącznik 2USB
- przełącznik Techly
- przełącznik Audiovox
Najnowsze instrukcje dla przełącznik
9 Kwietnia 2025
9 Kwietnia 2025
7 Kwietnia 2025
5 Kwietnia 2025
4 Kwietnia 2025
4 Kwietnia 2025
4 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
2 Kwietnia 2025