INSTRUCTIONS
SEPARATION KIT
RMK-3
Thank you for purchasing the RMK-3
SEPARATION KIT
.
The RMK-3 allows you to install the mobile trans-
ceiver front panel separately from the main body for
added installation convenience and operation. Use
either the optional OPC-607, OPC-608 or OPC-609
SEPARATION CABLE
with the RMK-3.
• In this instruction, the illustration is described using the IC-
F5060 series transceiver.
■ Separation
The optional OPC-607 , OPC-608 (3 m; 9.84 ft) (8 m; 26.3 ft) or
OPC-609* (1.9 m; 6.3 ft)
SEPARATION CABLE
is required for in-
stalling the transceiver front panel and main body separately.
*For Europe version, only the OPC-609 is available.
q Turn the transceiver’s power OFF, then disconnect the DC
power cable.
w Unscrew the 4 bottom screws, then remove the bottom
cover from the transceiver in the direction of the arrow.
e Remove the front panel from the main body using a stan-
dard screw driver as shown below.
r Disconnect the flat cable from the front panel.
t Unscrew the 4 rear plate screws, then remove the rear
plates from both the front panel and main body attach-
ments.
☞ Continue to the back page.
Rear plate
*This illustration
shows the descrip-
tion for the front
panel attachment.
Unscrew the cir-
cuit board screw.
Front panel
Flat cable Main body
Front panel
Flat cable
Main body
Front panel
Standard
screw driver
qw
e
Bottom cover
CAUTION! To avoid damage to the transceiver, turn the
power OFF before separating the front panel from the
main body.
■ Supplied accessories
Main body attachment
Front panel attachment Flat cable
Mounting bracket Flat washers
(M5)
Spring washers
(M5)
Mounting screws
(M5 12)×
Self-tapping screws
(M5 16)×
Bracket screwsNuts (M5)
Icom, Icom Inc. and the logo are registered trademarks of Icom Incor-
porated (Japan) in the United States, the United Kingdom, Germany, France,
Spain, Russia and/or other countries.

1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan A-6573H-1EX Printed in Japan
© 2007 Icom Inc.
■ Mounting
2 types of mounting styles are available one is overhead—
mounting, and other one is on-board mounting.
Mount the front panel and the attachment securely with the
4 supplied screws to a thick surface which can support more
than 1.5 kg. (Overhead mounting)
On-board mounting
Overhead mounting
When using
self-tapping screws
Flat washer
Spring washer
Bracket
screw
Bracket screw
■ Attachment
For the front panel attachment:
q Connect the optional OPC-607, OPC-608 or OPC-609 to
the front panel attachment as shown below.
After the cable connection, replace the removed rear plate
and the 4 screws.
• The optional cable can be inserted into either the left or right
grooves as desired on the back of the attachment.
w Connect the flat cable (q) as shown below, and then at-
tach the front panel and the attachment (w).
• fl Ensure the at cable is inserted correctly, and not upside down.
For the main body attachment:
e Connect the optional OPC-607, OPC-608 or OPC-609 to
the main body attachment as shown below.
After the cable connection, replace the removed rear
plate.
• The optional cable can be inserted into either the left or right
grooves as desired on the back of the attachment.
r Connect the supplied flat cable* and ground cable (coming
from the RMK-3) as shown below.
*Ensure the at cable and attachment are inserted/attached cor-fl
rectly, and not upside down.
t Replace the removed bottom cover and 4 screws, then re-
connect the DC power cable.
Main body attachment
to transceiver s’
main body
Main body
Main body attachment*
Flat cable*
Flat cable*
from the RMK-3
Use the attached screw
OPC-607/
OPC-608/
OPC-609
Rear plate
Main body attachment
Cable groove
Use the screw re-
moved from the cir-
cuit board in step t
on the front page, to
connect the cable lug.
Front panel
Front panel attachment
Flat cable
q
w
Attach the front
panel and attach-
ment securely.
OPC-607/
OPC-608/
OPC-609 Rear plate
Front panel attachment
Use the screw re-
moved from the cir-
cuit board in step t
on the front page, to
connect the cable lug.
Cable groove
Printed on recycled paper with soy ink.
Specyfikacje produktu
Marka: | ICOM |
Kategoria: | radio |
Model: | RMK-3 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z ICOM RMK-3, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje radio ICOM
12 Września 2024
11 Września 2024
9 Września 2024
5 Września 2024
5 Września 2024
4 Września 2024
28 Sierpnia 2024
26 Sierpnia 2024
24 Sierpnia 2024
20 Sierpnia 2024
Instrukcje radio
- radio AIC
- radio Nikkei
- radio HQ
- radio Sony
- radio Ruark Audio
- radio Peaq
- radio Hitec
- radio Cotech
- radio Geneva
- radio Yamazen
- radio Digitech
- radio Ozito
- radio Orava
- radio Einhell
- radio GoGen
Najnowsze instrukcje dla radio
2 Kwietnia 2025
2 Kwietnia 2025
1 Kwietnia 2025
1 Kwietnia 2025
1 Kwietnia 2025
29 Marca 2025
26 Marca 2025
24 Marca 2025
14 Marca 2025
11 Marca 2025