Instrukcja obsługi JUNG TRUDA231
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla JUNG TRUDA231 (6 stron) w kategorii termostat. Ta instrukcja była pomocna dla 7 osób i została oceniona przez 4 użytkowników na średnio 3.7 gwiazdek
                        Strona 1/6
                    
                    
                    
 – Display of energy consumption for electric 
heating systems
 – Pulse width modulation (PWM) or two-point 
control system
 – Adjustable cycle time (PWM), hysteresis and 
minimum on/o time (two-point)
 – Switch on delay, such as for burners (with two-
point control)
 – Adaptation to valves normally open or closed
 – Valve protection (as a room temperature 
controller with and without a limiting function)
 – Resetting separate from user and installer settings
Description of functions
The programmable temperature controller 
automatically controls the room or oor temperature 
depending on the time and day of the week. The 
automated program can be interrupted at any time by 
manual entries.
The temperature controller has three selectable 
programs for heating which can be adapted to 
your individual comfort. The controller is equipped 
with an internal sensor for measuring the room 
temperature. In addition, an external remote sensor 
can be connected, for example to measure the oor 
temperature. The temperature controller compares 
the measured temperature with set values. If the 
temperature falls below the current setting, the 
heating system is turned on.
The  depends on the type of heating control method 
and is determined by the installer:
 –  The heating is Room temperature controller:
turned on when the room temperature falls below 
the set target temperature (measured with an 
internal sensor or external remote sensor).
 –Floor temperature controller: The oor heating 
is turned on when the oor temperature falls 
below the set target temperature (measured 
using an external remote sensor).
 –Room temperature controller with a limiter  
(in conjunction with oor heaters): 
The room temperature is measured and 
regulated using the internal sensor. An additional 
external remote sensor is connected to measure 
the oor temperature, and a target temperature 
range for the oor is set. The room temperature 
control is deactivated when the oor temperature 
is outside of this range. If temperature falls 
below this range, the heater is turned on, and if 
the temperature is above this range, the heater 
is turned o independent of the current room 
temperature.
Operation
(9)
(10)
(11)
(12)
(13)(14)(15)(16)
(8)
Fig. 2: Default display
(8)  Function display (such as the mode)
(9)  Large display (such as the current temperature)
(10) Day of the week display  
(1 =  Monday ... 7 =  Sunday)
(11) Heating mode display
(12) Display (such as the current time)
(13) O button (info/OK)
(14) + button
(15) - button
(16) M button (menu)
Safety instructions
The unit may only be opened by an electrician 
and installed according to the circuit diagram on 
the unit or in these instructions. Observe existing 
safety instructions.
To satisfy the requirements of protection class 
II, corresponding installation measures are 
required.
This independently installable electronic device 
is exclusively for controlling the temperature in 
dry, enclosed rooms with normal surroundings.
This device is in conformance with EN 60730 and 
functions according to operating mode 1C.
Damage to the device, re or other hazards may 
arise if these instructions are not followed.
These instructions are a component part of the 
product and must remain with the end customer.
Structure of the device
(2)
(3)
(1)
(4)
(5)
(6)
(7)
Fig. 1: Layout of the temperature controller
(1)  Controls
(2)  Display
(3)  Control buttons
(4)  Plug-in contacts
(5)  Design frame (not including delivery)
(6)  Socket for the plug-in contacts
(7)  Use
Function
Correct use
 – Measuring and controlling the room temperature
 – Measuring and controlling the oor temperature
 – Room temperature control via oor heating with 
a limiting function (for example in conjunction 
with tiled stoves)
 – Can be used for “heating only” or “cooling only”
 – Installable in a box in conformance with 
DIN 49073
 – Only for use in dry, enclosed rooms
Product characteristics
 – Large display with backlighting
 – Text display for self-explanatory operation
 – Programmable even when the controls are 
removed
 – Dierent user languages can be selected
 – Real-time clock with automatic switchover to/
from daylight savings time
 – Internal temperature sensor
 – An external remote sensor can be connected
 – Three selectable and adjustable time 
temperature programs for automatic mode
 – A maximum of nine operating times per day (the 
setting can also be terminated after a specic 
operating time)
 – Can be individually programmed every day, or a 
block of operating times can be set: workdays/
non-workdays, all days the same
 – Can be manually adjusted at any time
 – “Vacation” mode with the entered date (from/to)
 – “At-home” mode (present)
 – Short-time timer (“party function”)
 – Optimum start” function (the temperature is 
reached at the set time)
 – Protection against frost
Universal room temperature controller 
with display
Ref.-no.: TR UD .. 231 ..
Operating instructions
GB
ALBRECHT JUNG GMBH & CO. KG 
Volmestraße 1 
58579 Schalksmühle 
GERMANY
Tel. +49 2355 806-0 
Fax +49 2355 806-204 
kundencenter@jung.de 
www.jung.de
08/2015 
0024073501
Specyfikacje produktu
| Marka: | JUNG | 
| Kategoria: | termostat | 
| Model: | TRUDA231 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z JUNG TRUDA231, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termostat JUNG
                        
                         4 Kwietnia 2025
                        
                    
                                                            
                        
                         3 Kwietnia 2025
                        
                    
                                                            
                        
                         1 Października 2024
                        
                    
                                                            
                        
                         27 Września 2024
                        
                    
                                                            
                        
                         27 Września 2024
                        
                    
                                                            
                        
                         27 Września 2024
                        
                    
                                                            
                        
                         26 Września 2024
                        
                    
                                                            
                        
                         25 Września 2024
                        
                    
                                                            
                        
                         10 Września 2024
                        
                    
                                                            
                        
                         10 Września 2024
                        
                    
                                                            Instrukcje termostat
- Etherma
- Salus
- Kemot
- Hama
- EVE
- Econo-Heat
- EQ-3
- Honeywell
- Grasslin
- Tru Components
- Junkers
- Dimplex
- Hornbach
- HomePilot
- STI
Najnowsze instrukcje dla termostat
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         6 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025