Instrukcja obsługi Technoline WL 1000
                    Technoline
                    
                    Radiobudzik
                    
                    WL 1000
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Technoline WL 1000 (2 stron) w kategorii Radiobudzik. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 6 użytkowników na średnio 4.7 gwiazdek
                        Strona 1/2
                    
                    
                    
Year (flashing)
"Date. Month."
(for 24h time display)
"Month. Date."
(for 12h time display)
Minutes (flashing)
Hours (flashing)
AIR QUALITY MONITOR 
Instructions manual 
INTRODUCTION: 
Congratulations on purchasing this Air Quality Monitor with display of 
indoor temperature and humidity. It is further acting as a DCF-77 radio 
controlled clock with calendar display and alarm clock function. This 
innovative product is ideal for use in the home or office. 
FEATURES: 
•  DCF radio controlled time with manual setting 
•  DCF Time reception ON/OFF 
•  Time zone setting: ± 12 hours 
•  12/24h time display 
•  Calendar display 
•  Alarm setting with snooze function 
•  Indoor temperature display in ºC / ºF 
•  Indoor humidity display in RH% 
•  Air quality alert setting 
•  Air quality indicator 
•  Low battery indicator 
•  LED Back-light 
SETTING UP: 
1.  Open the battery cover at the back of the air quality monitor as 
indicated below. 
2.  Checking the correct polarization, insert 2 x C, IEC LR14, 1.5V 
Alkaline batteries into the battery compartment and replace the 
cover. 
3.  When the batteries are inserted, all the segments of the LCD 
will light up briefly and a “beep” will sound. The air quality 
monitor will now start receiving the DCF time signal. After 
approximate 3 to 5 minutes, the DCF time will be displayed. 
4.  If after 10 minutes, the DCF time has not been received, press 
the SET key to manually enter a time initially. 
Note:  
•  The Equivalent CO
2  
ppm will only be displayed after 30 
minutes. 
•  The air quality sensor will take up to 5 days after inserting 
batteries to condition itself for the room it is placed. If the unit is 
placed into another room, there might be a reconditioning time 
of several days as well. 
INSTALLING AND REPLACING THE BATTERY IN THE 
AIR QUALITY MONITOR 
The air quality monitor 
uses 2 x C, IEC LR14, 
1.5V batteries. To 
install and replace the 
batteries, please 
follow the steps below: 
1.  Remove the cover at the back of the air quality monitor.  
2.  Insert batteries observing the correct polarity (see marking). 
3.   Replace compartment cover.
BATTERY CHANGE: 
It is recommended to replace the batteries in the unit regularly to 
ensure optimum accuracy of the unit (Battery life See   Specifications
below). 
Please participate in the preservation of the 
environment. Return used batteries to an authorised 
depot. 
DCF RADIO CONTROLLED TIME 
The time base for the radio controlled time is a Cesium Atomic Clock 
operated by the Physikalisch Technische Bundesanstalt 
Braunschweig which has a time deviation of less than one second in 
one million years. The time is coded and transmitted from Mainflingen 
near Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a 
transmitting range of approximately 1,500 km. Your radio-controlled 
clock receives this signal and converts it to show the precise time in 
summer or wintertime. 
The quality of the reception depends greatly on the geographic 
location. In normal cases, there should be no reception problems 
within a 1,500 km radius of Frankfurt. 
DCF reception is done twice daily at 02:00 and 03:00 am. If the 
reception is not successful at 03:00 am, then the next reception takes 
place the next day at 02:00 am. 
If the tower icon flashes, but does not set the time or the DCF tower 
does not appear at all, then please take note of the following: 
•  Recommended distance to any interfering sources like 
computer monitors or TV sets is a minimum of 1.5 - 2 meters. 
•  Within ferro-concrete rooms (basements, superstructures), the 
received signal is naturally weakened. In extreme cases, 
please place the unit close to a window and/ or point its front or 
back towards the Frankfurt transmitter. 
•  During nighttime, the atmospheric disturbances are usually less 
severe and reception is possible in most cases. A single daily 
reception is adequate to keep the accuracy deviation below 1 
second. 
KEY FUNCTIONS: 
The Air Quality Monitor has 5 easy-to-use keys: 
SET key: 
•  Press and hold to enter the manual setting modes: time zone, 
DCF ON/OFF, 12/24 hour time display, manual time, calendar 
display, snooze time, ºC / ºF temperature display, alert settings 
•  Press briefly to display the calendar for about 6 seconds 
•  Stop alarm ringing 
+ key: 
•  Press to change, set, toggle all manual settings 
•  Stop alarm ringing 
MODE key: 
•  Press to toggle between: alarm time, seconds, and Equivalent 
CO
2  
ppm display 
•  Stop alarm ringing 
•  Exit the manual setting mode 
ALARM key: 
•  Press and hold to enter the alarm setting mode 
•  Activate / deactivate the alarm 
•  Stop alarm ringing 
•  Exit the manual setting mode 
SNOOZE key: 
•  Enter snooze during alarm ringing 
•  Exit the manual setting mode 
LCD SCREEN 
MANUAL SETTINGS: 
The following manual settings can be done in the setting mode: 
•  Time zone setting 
•  DCF ON/OFF setting 
•  12/24 hour time setting 
•  Time setting 
•  Calendar setting 
•  Snooze setting 
•  ºC / ºF temperature display setting 
•  Air quality alert setting 
Press and hold the SET button for about 3 second to enter the setting 
mode: 
TIME ZONE SETTING 
The time zone default is "0 hour. To set a different time zone: " 
1.  The current time zone value starts flashing. 
2.  Use the   key to set the time zone. The range runs from 0, 1, +
2…12, -12, -11, -10… -2, -1, 0, in consecutive 1-hour intervals. 
3.  Confirm with the  key and enter the SET  Time reception 
On/Off setting. 
TIME RECEPTION ON/OFF SETTING 
In area where reception of the radio-controlled time (DCF time) is not 
possible, the time reception function can be turned OFF. The clock will 
then work as a normal quartz clock. (Default setting is ON). 
1.  The digit “ON” and tower icon will start flashing on the LCD. 
2.  Use the   key to turn OFF the time reception function if +
necessary. 
3.  Confirm with the   key and enter the SET 12/24 hour time 
display setting. 
Note: 
If the Time Reception function is turned OFF manually, the clock will 
not attempt any reception of the radio-controlled time (DCF time) as 
long as the Time Reception OFF function is activated. The Time 
Reception icon and the DCF icon will not be displayed on the LCD.
12/24 HOUR TIME DISPLAY SETTING 
1.  “12hr” or “24hr” flashes in the LCD. (default 24hr) 
2.  Press the   key to select the “12hr” or “24hr” display mode. +
3.  Confirm with the   key and enter the  . SET Manual time setting
Note:  
When 24h time display is selected, the calendar format will be date 
and month display. When 12h time display is selected, the calendar 
format will be month and date display.
MANUAL TIME SETTING 
In case the air quality monitor is not able to detect the radio-controlled 
time (DCF time) signal (disturbances, transmitting distance, etc.), the 
time can be manually set. The clock will then work as a normal Quartz 
clock. 
To set the clock: 
1.  The hour digits start flashing in the time display section. 
2.  Use the   key to adjust the hours and then press  key to go + SET 
to the minute setting. 
3.  The minute will be flashing. Press the   key to just the minutes. +
4.  Confirm with the   key and enter the  . SET Calendar setting
Note: 
The unit will still try to receive the signal despite a manual setting. 
When the signal is received, the manually set time will automatically 
be replaced by the received time. During reception attempts, the DCF 
tower icon will flash. If reception has been unsuccessful, the DCF 
tower icon will not appear but reception will still be attempted. 
CALENDAR SETTING 
The date default of the air quality monitor is 1. 1. of the year 2013 
after initial set-up. Once the radio-controlled time signals are received, 
the date is automatically updated. However, if the signals are not 
received, the date can also be set manually. To do this: 
1.  The year starts flashing. Use the  key, set the year required. + 
The range runs from 2013 to 2049 (default is 2013). 
2.  Press the   key to enter the month setting. SET
3.  The month digit will be flashing. Press the   key to set the +
month. 
4.  Press the  T key to enter the date setting.  SE
5.  The date digit will be flashing. Press the   key to set the date. +
6.  Confirm with the   key and enter the  . SET Snooze setting
SNOOZE SETTING
The snooze time can be set OFF or to a maximum time of 30 minutes 
(default is 10 minutes): 
1.  The snooze time (in minute) digit will be flashing. Use the   key +
to set the snooze time (in minute). Each pressing of the button 
will increase the snooze time by 5 minutes (5, 10…30 min). 
The snooze can also be set OFF when the “OFF” digit is being 
displayed. 
2.  Confirm with the   button and enter the SET ºC/ºF temperature 
unit setting. 
Note: 
If the snooze time has been set “OFF”, the snooze function will not be 
activated.
°C/°F TEMPERATURE UNIT SETTING
The default temperature reading is set to °C (degre e Celsius). To 
select °F (degree Fahrenheit): 
1.  The “°C” will be flashing, use the   key to toggle between “°C” +
and “°F”. 
2.  Confirm with the   key and enter the SET Air quality alert 
setting. 
AIR QUALITY ALERT SETTING 
The air quality monitor has 3 alert settings (default: ALL): 
Function keys
LCD display
Function key 
Battery
compartment
SET key
ALARM key 
+ key  MODE key 
SNOOZE key 
Flashing 
Time
Low battery icon
Indoor temperature
in ºC/ºF
Alarm time / 
Equivalent CO
2  
ppm / seconds 
display
Indoor relative 
humidity % RH
Alarm icon 
DCF Tower icon (for time reception)
Flashing 
Flashing
Flashing 
Flashing
Air quality indicator
Flashing
Specyfikacje produktu
| Marka: | Technoline | 
| Kategoria: | Radiobudzik | 
| Model: | WL 1000 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Technoline WL 1000, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Radiobudzik Technoline
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         26 Września 2024
                        
                    
                                                            
                        
                         26 Września 2024
                        
                    
                                                            
                        
                         19 Września 2024
                        
                    
                                                            
                        
                         17 Września 2024
                        
                    
                                                            
                        
                         16 Września 2024
                        
                    
                                                            
                        
                         15 Września 2024
                        
                    
                                                            
                        
                         15 Września 2024
                        
                    
                                                            
                        
                         15 Września 2024
                        
                    
                                                            
                        
                         14 Września 2024
                        
                    
                                                            Instrukcje Radiobudzik
- Enhance
- IHome
- Soundmaster
- JGC
- Essentiel B
- Beurer
- Elro
- Audiovox
- GoGen
- Salora
- Ditalio
- Nikkei
- Lanaform
- Sangean
- Nedis
Najnowsze instrukcje dla Radiobudzik
                        
                         15 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         9 Października 2024
                        
                    
                                                            
                        
                         8 Października 2024