LCDT-Series UPS Systems
Models:
SMART1500LCDT, OMNI1500LCDT, SMART1300LCDT
(AG-0066, AG-0067, AG-0068)
Important Safety Instructions 2
Quick Installation 3
Basic Operation 4
UPS On/Off 4
LCD Display 5
Display UPS/Power Conditions 6
Enable/Disable Alarm 6
Self-Test 7
Error Messages 7
Features 8
Battery Replacement 9
Storage and Service 10
Warranty Registration 11
Español 13
Français 25
Owner’s Manual
Warranty
Registration
Register online today for a
chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2012 Tripp Lite. All rights reserved. SmartPro
® is a registered trademark of Tripp Lite.
TEST MUTE
TEST MUTE
12-12-069-93-327C.indb 1 12/6/2012 9:28:34 AM

2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and
storage of this product. Failure to heed these warnings may affect the warranty.
UPS Location Warnings
• InstallyourUPSindoors,awayfromexcessmoistureorheat,conductivecontaminants,dustordirectsunlight.
• Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF(0ºCand40ºC).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.
• OnlysettheUPSuprightonasturdyatsurface.Donotblockfansorventilationholes,asthiswillseriouslyinhibittheunit'sinternal
cooling and cause product damage not covered under warranty.
UPS Connection Warnings
• ConnectyourUPSdirectlytoaproperlygroundedACpoweroutlet.DonotplugtheUPSintoitself;thiswilldamagetheUPS.
• DonotmodifytheUPS’splug,anddonotuseanadapterthatwouldeliminatetheUPS’sgroundconnection.
• DonotuseextensioncordstoconnecttheUPStoanACoutlet.
• IftheUPSreceivespowerfromamotor-poweredACgenerator,thegeneratormustprovideclean,ltered,computer-gradeoutput.
• ThemainssocketoutletthatsuppliestheUPSshouldbeeasilyaccessibleandlocatedneartheUPS.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonablybeexpectedtocausethefailureof
thelifesupportequipmentortosignicantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthe
presenceofaammableanestheticmixturewithair,oxygenornitrousoxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.ThismightdamagetheUPSandmayaffectthesurge
suppressor and UPS warranties.
• ConnecttheUPStoanoutletthatisadequatelyprotectedagainstexcesscurrents,shortcircuitsandearthfaultsaspartofthe
building installation.
Battery Warnings
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observeproperprecautions.Thereareno
user-serviceablepartsinsidetheUPS.DonotopentheUPSexcepttoperformbatteryreplacement.Donotopenbatteries.Donot
short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools
withinsulatedhandles.Batteryreplacementshouldbeperformedonlybyauthorizedservicepersonnelusingthesamenumberand
typeofbatteries(SealedLead-Acid).Donotdisposeofthebatteriesinare.Thebatteriesarerecyclable.Refertoyourlocalcodes
fordisposalrequirementsorintheUSAonlycall1-800-SAV-LEADor1-800-8-BATTERY(1-800-822-8837)orvisitwww.rbrc.com
forrecyclinginformation.TrippLiteoffersacompletelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteon
theWebatwww.tripplite.com/support/battery/index.cfmtolocatethespecicreplacementbatteryforyourUPS.
Important Safety Instructions
12-12-069-93-327C.indb 2 12/6/2012 9:28:34 AM

3
STEP 1: Plug the UPS into a properly grounded outlet.
After plugging the UPS into a wall outlet, press and hold the POWER BUTTONforone
secondtoturnontheUPS(SeeBasicOperationSection).
Note: The UPS will not turn on automatically in the presence of live utility power.
STEP 2: Plug your equipment into the UPS.
There are two sets of outlets on the back of your UPS. Outlets marked SURGE PROTECTED
do not provide battery backup power during power outages. Connect common desktop
itemslikeprinters,scannersandotheraccessoriesnotrequiringbatterysupporttothese
outlets.
OutletsmarkedBATTERY/SURGEPROTECTED offer UPS battery backup support during
powerfailures.Connectyourvitalcomputerequipmentintotheseoutlets.
YourUPSisdesignedtosupportelectronicequipmentonly.YouwilloverloadtheUPSif
thetotalVAratingsforalltheequipmentconnectedtotheBATTERY/SURGEPROTECTED
outletsexceedtheUPSoutputcapacity.Tondyourequipment’sVAratings,lookontheir
nameplates.Ifthe equipment islistedin amps, multiplythe numberofamps by 120to
determineVA.Forexample:1amp×120=120VA.Ifyoususpectyouhaveoverloaded
the outlets, check the Load Percentage and Load Meter screens (See Display UPS/Power
ConditionsdescriptionsinBasicOperationSection).Ifyouarestillunsure,runaself-test
(SeeSelf-TestdescriptioninBasicOperationSection).
Optional Installation
AllmodelsincludeUSBcommunicationports,tel/DSL/Ethernet(NotcompatiblewithPoE
applications)surgeprotectionjacksandcoaxiallineprotectionjacks.Theseconnections
areoptional;theUPSwillworkproperlywithouttheseconnections.Seetheconnector's
descriptionintheBasicOperationsectionforconnectioninstructions.
IftheLINEPOWERicon doesnotilluminatewhentheUPSisturnedON,trythefollowing:
1. Make sure that the UPS is plugged into a live AC outlet.
2. Press and hold the POWER BUTTONforonesecondtoturnontheUPS.Abeepshould
sound when the UPS starts.
3. IftheUPSstilldoesnotstart,contactTrippLiteTechSupportforassistance.
Quick Installation
12-12-069-93-327C.indb 3 12/6/2012 9:28:35 AM
Specyfikacje produktu
Marka: | Tripp Lite |
Kategoria: | UPS |
Model: | SmartPro SMART1500LCDT |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Tripp Lite SmartPro SMART1500LCDT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS Tripp Lite
30 Grudnia 2025
9 Października 2024
9 Października 2024
9 Października 2024
4 Października 2024
1 Października 2024
29 Września 2024
29 Września 2024
16 Września 2024
15 Września 2024
Instrukcje UPS
- UPS GYS
- UPS FSP/Fortron
- UPS Approx
- UPS Maruson
- UPS FSP
- UPS Salicru
- UPS Adj
- UPS East
- UPS V7
- UPS Altronix
- UPS Block
- UPS Liebert
- UPS CyberPower
- UPS Schneider
- UPS Vanson
Najnowsze instrukcje dla UPS
2 Kwietnia 2025
2 Kwietnia 2025
30 Marca 2025
29 Marca 2025
29 Marca 2025
29 Marca 2025
29 Marca 2025
29 Marca 2025
29 Marca 2025
27 Marca 2025