Instruction manual
SAFETY INSTRUCTIONS
• Please read this user’s manual carefully to ensure
proper use, maintenance and installation.
• The appliance is for indoor use only.
• Do not use the unit on a socket under repairs or not
installed properly
• Do not use the unit, follow these precautions:
o Near to source of re.
o An area where oil is likely to splash.
o An area exposed to direct sunlight.
o An area where water is likely to splash.
o Near a bath, a laundry, a shower or a swimming
pool.
• Never insert your ngers, rods into the air outlet.
Take special care to warn children of these dangers.
• Keep the unit upward while transport and storage,
for the compressor locates properly.
• Before cleaning the air-conditioner, always turn o
or disconnect the power supply.
• When moving the air-conditioner, always turn o
and disconnect the power supply, and move it
slowly.
• To avoid the possibility of re disaster, the air-
conditioner shall not be covered.
• All the air-conditioner sockets must comply with
the local electric safety requirements. If necessary,
please check it for the requirements.
• Children should be supervised to ensure that they
do not play with the appliance.
• If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
• This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made
by children without supervision.
• The appliance shall be installed in accordance with
national wiring regulations.
• Notes:
o If any parts damage, please contact the dealer or a
designated repair shop;
o In case of any damage, please turn o the air
switch, disconnect the power supply, and contact
o The dealer or a designated repair shop;
o In any case, the power cord shall be rmly
grounded.
o To avoid the possibility of danger, if power cord
is damaged, please turn o the air switch and
disconnect the power supply. It must be replaced
from the dealer or a designated repair shop.

3
EN
WARNING
• Do not use means to accelerate the defrosting
process or to clean, other than those recommended
by the manufacturer.
• The appliance shall be stored in a room without
continuously operating ignition sources (for
example: open ames , an operating gas appliance
or an operating electric heater).
• Do not pierce or burn.
• Be aware that refrigerants may not contain an odor.
• Appliance shall be installed, operated and stored
in a room with a oor area larger than X m2. (X=4
for 5000Btu/h, 7000Btu/h, 8000Btu/h; X=7.7 for
9000Btu/h, 10000Btu/h, 10500Btu/h)
• Contact authorized service technician for repair or
maintenance of this unit.
• Do not pull , deform. or modify the power supply
cord , or immerse it in water . Pulling or misuse of
the power supply cord can result in damage to the
unit and cause electrical shock.
• Compliance with national gas regulations shall be
observed.
• Keep ventilation openings clear of obstruction.
• Any person who is involved with working on or
breaking into a refrigerant circuit should hold
a current valid certicate from an industry-
accredited assessment authority, which authorizes
their competence to handle refrigerants safely
in accordance with an industry recognized
assessment specication.
• Servicing shall only be performed as recommended
by the equipment manufacturer. Maintenance
and repair requiring the assistance of other
skilled personnel shall be carried out under the
supervision of the person competent in the use of
ammable refrigerants.
• Do not operate or stop the unit by inserting or
pulling out the power plug, it may cause electric
shock or re due to heat generation .
• Unplug the unit if strange sounds, smell, or smoke
comes from it.
Air conditioner
Specyfikacje produktu
Marka: | TriStar |
Kategoria: | klimatyzacja |
Model: | AC-5529 |
Kolor produktu: | Biały |
Pojemność zbiornika na wodę: | 0.5 l |
Materiał obudowy: | Kopolimer akrylonitrylo-butadieno-styrenowy (ABS) |
Regulowany termostat: | Tak |
Wbudowany wyłącznik: | Tak |
Wbudowany wyświetlacz: | Tak |
Długość przewodu: | 1.8 m |
Typ wyświetlacza: | LCD |
Częstotliwość wejściowa AC: | 50 Hz |
Napięcie wejściowe AC: | 240 V |
Wysokość produktu: | - mm |
Szerokość produktu: | - mm |
Głębokość produktu: | - mm |
Waga produktu: | 19000 g |
W zestawie pilot zdalnego sterowania: | Tak |
Podręcznik użytkownika: | Tak |
Szerokość opakowania: | 318 mm |
Wysokość opakowania: | 878 mm |
Głębokość opakowania: | 373 mm |
Poziom hałasu: | 65 dB |
Prąd: | 4.5 A |
Obciążenie: | 980 W |
Minutnik: | Tak |
Waga wraz z opakowaniem: | 21000 g |
Model: | Przenośny klimatyzator powietrza |
Typ wtyczki zasilającej: | Type F (CEE 7/4) |
Kółka: | Tak |
Produkty na jeden kontener intermodalny (20ft): | 216 szt. |
Produkty na jeden kontener intermodalny (40ft): | 452 szt. |
Produkty w jednym kontenerze intermodalnym (40ft, HC): | 674 szt. |
Stopień ochrony IP: | IP20 |
Rodzaj timera: | Cyfrowy |
Urządzenie rozmrażające: | R290 |
Prędkości: | 2 |
Zdalnie sterowany: | Tak |
Przeznaczone dla powierzchni pokojowej do: | 80 m² |
Wskaźnik pełnego zbiornika wody: | Tak |
Funkcje wentylacji: | Cooling, Dehumidifying, Fan |
Wydajność chłodzenia w watach (nominalna): | - W |
Średnia waga chłodnicza: | 160 g |
Godzinne zużycie energii (chłodzenie): | - kWh |
Godzinne zużycie energii (ogrzewanie): | - kWh |
Roczne zużycie energii (chłodzenie): | - kWh |
Enegretyczna wydajność chłodzenia: | 2.61 |
Maksymalna wydajność chłodzenia w watach: | 2630 W |
Moc grzewcza w watach (nominalna): | - W |
Maksymalna wydajność ogrzewania w watach: | - W |
Maksymalna wydajność chłodzenia: | 9000 BTU/h |
Przepływ powietrza (wysoka prędkość): | 320 m³/h |
Zdolność osuszania: | 1.2 l/h |
Klasa energetyczna (chłodzenie): | A |
Przepływ powietrza (niska prędkość): | 280 m³/h |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z TriStar AC-5529, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje klimatyzacja TriStar
20 Października 2024
5 Października 2024
1 Października 2024
12 Września 2024
10 Września 2024
9 Września 2024
8 Września 2024
4 Września 2024
4 Września 2024
4 Września 2024
Instrukcje klimatyzacja
- klimatyzacja Emerson
- klimatyzacja Bomann
- klimatyzacja Khind
- klimatyzacja GUTFELS
- klimatyzacja Sôlt
- klimatyzacja Monzana
- klimatyzacja Eden
- klimatyzacja Ansonic
- klimatyzacja DCG
- klimatyzacja Igenix
- klimatyzacja Sungrow
- klimatyzacja Domo
- klimatyzacja Balay
- klimatyzacja Ariston Thermo
- klimatyzacja Wilfa
Najnowsze instrukcje dla klimatyzacja
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025