Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
01489EN  01  1904
01489
Home  automation  control  device  with  four  push  buttons,  1  0/1-10  V 
SELV output, 1 NO contact relay output 2A 120-240  V~ 50/60  Hz for 
ballast and LED driver, visible in darkness with RGB LEDs with inten-
sity  adjustment,  to  be  completed  with  interchangeable  half-button 
caps comprising 1 or 2 modules (Eikon) or 2 modules (Arkè or Plana).
The device is equipped with independent push buttons that can also be configured 
as rocker buttons, 0/1-10 V SELV proportional actuator for ballast and LED driver (the 
relay cuts off the load), 0/1-10 V SELV climate control proportional relay for motorised 
proportional valves (the relay does not cut off the load), RGB LEDs with configurable 
colour,  for  setting  and  control  functions  in  By-me  home  automation  systems.  The 
0/1-10  V  output  is  galvanically  isolated  (double  insulation  or  reinforced  insulation) 
from the mains power supply and from the BUS. For the Eikon and Arkè series, all 
the button covers, whether from the catalogue or customised, have symbols which 
can be backlit with customisable RGB colours.
FEATURES.
• Rated supply voltage: 29 V BUS
• Absorption from the BUS: 25 mA
• Distance between 0/1-10 V output and load: max 50 m with twisted cable
• Terminals:
- TP bus,
- relay contacts (C, NO)
- 0/1-10 V SELV control
- 0/1-10 V SELV maximum output current: 
- 30 mA absorption (load with 0/1-10 V SELV interface active)
- 10 mA delivery (load with 0/1-10 V SELV interface passive)
• 0/1-10 V SELV overload-protected output
• 4 push buttons which can also be configured as rocker buttons
• 4 RGB LEDs with configurable colour
• red LED and configuration push button
• Operating temperature: -5 °C ÷ +45 °C (indoor use)
• Protection degree: IP20
• Device 01489 should be configured with the Automation Gateway 01410-01411 
and App VIEW Pro.
• Not compatible with By-me control panels 21509 and EasyTool Professional.
CONTROLLABLE LOADS.
• Relay output (120 - 240 V~ controllable loads, NO contact):
- ballast and 2 A LED driver (5,000 cycles)
• 0/1-10 V SELV output:
- ballast and LED driver with 0/1-10 V SELV input
- motorised proportional valves with 0/1-10 V SELV input
Plug&Play. 
CAUTION: The plug&play mode requires the system to include only plug&play 
devices and not devices configured in the By-me Plus system.
For operation in Plug&Play mode, only install the 1-module fixed half-button caps 
on the device.
In the absence of a configuration, the device is pre-configured as a 0/1-10V propor-
tional actuator:
- briefly press   to B activate the relay actuator of the device;
- press   for a prolonged time to make the   (increase);B upwards adjustment
- briefly press   to C deactivate the relay actuator of the device;
- press   for a prolonged time to make the   (decrease);C downwards adjustment
- press   to send a “ ” scenario over the bus;F Lights OFF
- press   to send a “E Lights OFF and roller shutters DOWN” scenario over the bus.
When push buttons are pressed, the LEDs are on for 3 s.
SETTING THE COLOUR OF THE LEDS.
PLUG&PLAY mode. 
• Procedure activation: simultaneously press push buttons E and F for a prolonged 
time; the LEDs will all illuminate in the colour currently set. 
• E F Colour selection: briefly press push button   or   to view the next colour.
• Saving  the  colour  and  exiting  the  procedure:  press  push  button  F  or  E  for  a 
prolonged time.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of 
its life must be collected separately from other waste. The user must therefore hand the equipment 
at the end of its life cycle over to the appropriate municipal centres for the differentiated collection of 
electrical and electronic waste. As an alternative to independent management, you can deliver the 
equipment you want to dispose of free of charge to the distributor when purchasing a new appliance 
of an equivalent type. You can also deliver electronic products to be disposed of that are smaller 
than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area of at 
least 400 m2. Proper sorted waste collection for subsequent recycling, processing and environmen-
tally conscious disposal of the old equipment helps to prevent any possible negative impact on the 
environment and human health while promoting the practice of reusing and/or recycling materials 
used in manufacture.
• Exiting the procedure without saving the colour: automatic after a timeout of 5 s.
B  y-me Plus SYSTEM.
• The colour is set from the App using the respective menus. 
OPERATION.
Home automation device acting as a proportional actuator.
• Possible functions:
- Dimming control/adjustment of ballast and LED driver with 0/1-10 V SELV control 
interface (the load can be cut off by the relay).
- Operating motorised proportional valves  with 0/1-10  V  SELV control interface for 
temperature control systems (the load cannot be cut off by the relay).
At power-on the relay is set to OFF status. The subsequent status varies according 
to a configurable parameter.
CONFIGURATION.
For the configuration operations, see the By-me Plus system manual.
• Functional units: 7
- Top left push button functional unit
- Bottom left push button functional unit
- Top right push button functional unit
- Bottom right push button functional unit
- Left rocker button functional unit
- Right rocker button functional unit
- Proportional actuator functional unit
INSTALLATION RULES.
• If motorised valves are connected, these must be class III and equipped with the 
 symbol.
• If ballasts or LED drivers are connected, these can either be class I or class II with 
the 0/1-10V SELV output.
•  The  0/1-10  V  interface  of  the  controlled  loads  must  be  isolated  from  the  mains 
power supply by double insulation or by reinforced insulation.
• Installation must be carried out by qualified persons in compliance with the current 
regulations regarding the installation of  electrical equipment  in the country where 
the products are installed.
• The relay output power circuit must be protected against overloads by installing a 
device, fuse or automatic 1-way switch, with a rated current not exceeding 10 A.
• Installation in flush mounting box. In the event of installation on a control unit, use 
the related accessory art. V51922.
• If this device is used for purposes other than those specified by the manufacturer, 
the protection provided may be compromised.
• Observe the maximum current and voltage values given for the device.
REGULATORY COMPLIANCE.
LV Directive. EMC directive. Standards EN 60669-2-5, EN 50491.
REACH  (EU)  Regulation  no.  1907/2006  –  Art.33.  The product  may  contain  traces 
of lead.
Specyfikacje produktu
| Marka: | Vimar | 
| Kategoria: | Opornik | 
| Model: | 01489 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Vimar 01489, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Opornik Vimar
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            
                        
                         15 Grudnia 2024
                        
                    
                                                            Instrukcje Opornik
- BeamZ
- Ehmann
- GE
- GAO
- Berker
- Ltech
- Merten
- Schneider Electric
- Grasslin
- Homematic IP
- JUNG
- Peha
- Intertechno
- VAMA
- Velleman
Najnowsze instrukcje dla Opornik
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         12 Marca 2025
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024
                        
                    
                                                            
                        
                         7 Października 2024