Strona 1/2

Installation Guide
CB-MXP10 Rough-In Box and Cover Plate for Modero X 10” Panel
Overview
The CB-MXP10 Rough-In Box (FG039-17) is an optional accessory for the Modero X
Series 10” Wall Mount Touch Panel. It allows the panel to be mounted directly to the
studs/pre-wall.
The back of the Modero X Series 10” Wall Mount Touch Panel is contained within a
plastic outer housing or back box, and the back box attaches to the Rough-In Box. The
Rough-In Box kit includes a wall box, cover, and mounting screws.
Specifications
WARNING: In order to guarantee a stable installation of the touch panel, the distance
between the CB-MXP10 and the outer wall surface must be a minimum of .50 inches
(1.27cm) and a maximum of .1.50 inches (3.81cm).
• Refer to the 95-5968-34 diagram for detailed installation dimensions.
Pre-Wall Installation of the CB-MXP10 Rough-In Box
1. Remove the rough-in box cover (B in FIG. 1) before installation of the Rough-In
Box (A). Note: the cover MUST be removed before drywall installation. The
cover may be reinstalled after drywall installation using 4-40 screws (not
included).
2. Fasten the CB-MXP10 rough-in box to the stud through the holes on the Stud
Mounting tabs, using either nails or screws (not provided).
3. Additional framing or blocking may be desired for a more robust mounting.
4. Remove the appropriate wiring knockouts from the rough-in box to
accommodate the cables being threaded through to the 19” or 20” Wall Mount
Touch Panel.
5. Thread the incoming Ethernet and USB wiring through the knockouts. Using the
left wiring knockouts for USB connector cables and the right wiring knockouts for
the LAN/PoE In cable is very highly recommended with this installation. Leave
enough slack in the wiring to accommodate installation of the docking station.
6. Install the drywall/sheetrock before inserting the back box for the CB-MXP10.
7. Cut out the opening for the Wall Mount Touch Panel back box where the wall has
been placed over the Rough-In Box. Cutting out the surface slightly smaller than
what is outlined in the installation drawings, so that you can make any necessary
cutout adjustments, is very highly recommended.
NOTE: The front cover of the CB-MXP10 (B in FIG. 1) should be installed after the
appropriate wiring is pulled to the Rough-In Box. The cover should then be removed
prior to the installation of the touch panel back box and discarded.
FIG. 1 CB-MXP10 Rough-In Box - with front cover
8.65”
(21.98 cm)
A
B
8.94”
(22.71 cm)
5.78”
(14.68 cm)
Rough-In Box
Rough-In Box With Cover
Cover
CB-MXP10 (FG039-17) Specifications
Dimensions (HWD) • Rough-In Box: 8 5/8" x 9 7/8" x 2 1/4" (22.0 cm x 22.7 cm x
5.7 cm)
• Rough-In Box Cover Plate: TBD
Weight • With cover: TBD
• Without cover: 1.80 lbs (0.82 kg)
Certifications • UL Listed
Included
Accessories: • Cover Plate for Rough-in Box (FG039-20)
• Back Box to Rough-In Box Mounting Screws (4)
( )80-5967-03
• Cover Plate to Rough-In Box Mounting Screws (4)
( )80-5967-03
Recommended
Wall Cutout
for the CB-MXP10
5.5”
(13.97 cm)
8.75”
(22.23 cm)

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
4/12
©2012 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-0039-17 REV: B
Cover
CB-MXP10
Rough-In Box
Without Cover
CB-MXP10
Rough-In Box
With Cover
(oblique angle)
Knock-outs
Front
(oblique angle)
Cover screws
2.24”
(5.68 cm)
8.94”
(22.71 cm)
2.24”
(5.68 cm)
5.78”
(14.68 cm)
2.39”
(6.08 cm)
6.48”
(16.6 cm)
2.39”
(6.08 cm)
8.94”
(22.71 cm)
Front
Specyfikacje produktu
Marka: | AMX |
Kategoria: | Wsparcie dla płaskich paneli |
Model: | CB-MXP10 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z AMX CB-MXP10, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Wsparcie dla płaskich paneli AMX
28 Września 2024
Instrukcje Wsparcie dla płaskich paneli
- Wsparcie dla płaskich paneli Konig
- Wsparcie dla płaskich paneli Dataflex
- Wsparcie dla płaskich paneli Silverstone
- Wsparcie dla płaskich paneli Monoprice
- Wsparcie dla płaskich paneli Amer
- Wsparcie dla płaskich paneli Valueline
- Wsparcie dla płaskich paneli Acco
- Wsparcie dla płaskich paneli Bell'O
- Wsparcie dla płaskich paneli Rocstor
- Wsparcie dla płaskich paneli Newstar
- Wsparcie dla płaskich paneli Pioneer
- Wsparcie dla płaskich paneli SMS Smart Media Solutions
- Wsparcie dla płaskich paneli LC-Power
- Wsparcie dla płaskich paneli Samsung
- Wsparcie dla płaskich paneli Crimson
Najnowsze instrukcje dla Wsparcie dla płaskich paneli
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
16 Stycznia 2025
16 Stycznia 2025
16 Stycznia 2025
16 Stycznia 2025