Instrukcja obsługi APC Back- Connect BGE70
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla APC Back- Connect BGE70 (2 stron) w kategorii UPS. Ta instrukcja była pomocna dla 10 osób i została oceniona przez 5.5 użytkowników na średnio 4.7 gwiazdek
                        Strona 1/2
                    
                    
                    
Inventory
Safety and General Information
Inspect the package contents upon receipt. Notify the 
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before 
installing the UPS.
•  This unit is designed for low power devices less than 75 Watts. When the UPS is 
on battery, the unit will shut down automatically to protect itself once the load on 
the UPS is greater than 75Watts.
•  This UPS is intended for indoor use only. 
•  Do not operate this UPS in direct sunlight, in contact with fluids, or where there is 
excessive dust or humidity.
•  Be sure the air vents on the UPS are not blocked. Allow adequate space for proper 
ventilation.
•  The battery typically lasts for three to five years. Environmental factors impact 
battery life. Elevated ambient temperatures, poor quality AC power, and frequent 
short duration discharges will shorten battery life.
•  Connect the UPS power cable directly to a wall outlet. Do not use surge protectors 
or extension cords.
Specifications
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected. 
Connect Equipment
Battery Backup Outlets
Battery backup outlets provide protection to connected equipment when the 
Back-UPS is turned on and connected to AC power.
Battery backup outlets receive power from the Back-UPS for a limited period of time 
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a broadband modem and wireless router to the outlets. Voice over IP (VOIP) 
phones (if applicable) should also be plugged into battery backup outlets.
To maximize runtime in the event of a power outage only connect networking 
equipment to battery backup outlets.
This UPS is designed to sustain low power devices for extended periods of time. 
When the UPS is on battery, the unit will shut down automatically if the load on the 
UPS exceeds 75Watts. Low power devices include modems, routers, USB chargers 
(5W and 10W), VOIP and cordless phones.
Turn On the Back-UPS
Press the POWER ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to 
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 16 hours while connected to AC 
power. The Back-UPS battery will charge while the Back-UPS is switched on or off 
and is connected to AC power. Do not expect full battery run capability during the 
initial charge time. 
Status Indicators
Wall Mount Installation
• Horizontal installation, use 2 screws 3-15/16” (100 mm) apart. 
• Allow 5/16” (8 mm), of the screw to protrude from the wall.
Input Voltage 120 Vac Nominal
Frequency 50/60 Hz + 3
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output UPS Capacity 
(3 battery backup outlets)
125 VA, 75 W
Total Amperage (all outlets) 1.04 A (including UPS output)
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 50/60 Hz + 1
Transfer Time 6 ms Typical, 10 ms maximum
Protection 
and 
Filtering
AC Surge Protection Full time, 90 Joules
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free, lead acid 
RBC153
Average Life 3 - 5 years depending on the number of 
discharge cycles and environmental 
temperature
Physical Net Weight 5.51 lb (2.5 kg)
Dimensions 
Length x Width x Height
8.9 in x 4.1 in x 5.2 in
22.5 cm x 10.5 cm x 13.2 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
 Remove the “Stop! Connect the 
Battery” label that covers the outlets.
 Press the battery compartment cover 
release tabs located on the rear side of the 
unit. Slide the battery cover off.
 Connect the battery cable securely to 
the battery terminal. It is normal for small 
sparks to be seen when the battery cable is 
connected to the battery terminal.
 Reinstall the battery compartment cover. 
Be sure that the release tab locks into place.
bu374a
bu379a
bu375a
bu376a
bu378a
Status Power Button 
LED
Audible 
Indicator On
Audible Indicator 
Terminates
Power On 
The Back-UPS is 
supplying AC power to 
connected equipment.
The LED 
illuminates green.
None N/A
On Battery
Back-UPS supplying 
battery power to battery 
backup outlets.
The LED 
illuminates green. 
The LED flashes 
once at the end of 
every 2 seconds.
Back-UPS 
beeps for 2 
seconds 
when 
entering 
battery 
mode.
Beeping stops at the 
end of the first two 
seconds. A constant 
beep at the initial 
two seconds 
indicates the Back-
UPS has entered the 
battery mode.
Low Battery warning
The Back-UPS is 
supplying battery power to 
the battery backup outlets 
and the battery is near a 
total discharge state.
The LED 
illuminates green 
and flashes in 
rapid succession.
The Back-
UPS emits 
rapid 
beeping, 
every 
1/2 second.
Beeping stops when 
AC power is 
restored or the Back-
UPS is turned off.
Replace Battery
• The battery is 
disconnected.
• The battery needs to be 
charged, or replaced.
The LED 
alternately 
illuminates green-
red.
Constant 
tone
Constant 
tone
Back-UPS is turned 
off.
Overload Shutdown
While on battery power an 
overload condition has 
occurred in one or more of 
the battery backup outlets 
while the Back-UPS is 
operating on battery 
power.
None Constant 
tone
Back-UPS is turned 
off.
Sleep Mode
While on battery power 
the battery is completely 
discharged. The 
Back-UPS will “awaken” 
once AC power is 
restored.
None The Back-
UPS beeps 
once every 
four seconds.
The beeping stops 
when: 
• AC power is 
restored
• If AC power is not 
restored within 32 
seconds
• The Back-UPS is 
turned off
bu377a
Wall-mounting Template
bu3
8
0
a
 100 mm
3        in.
User Manual Back-UPS™ Connect BGE 70/70-CA 120 Vac
Specyfikacje produktu
| Marka: | APC | 
| Kategoria: | UPS | 
| Model: | Back- Connect BGE70 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z APC Back- Connect BGE70, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS APC
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025
                        
                    
                                                            Instrukcje UPS
- Eaton
- Dell
- Online USV
- Phoenix Contact
- Liebert
- Atlantis Land
- GYS
- FSP/Fortron
- Hikvision
- Schneider
- Digitus
- Middle Atlantic
- Steren
- Voltcraft
- Puls Dimension
Najnowsze instrukcje dla UPS
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         5 Marca 2025
                        
                    
                                                            
                        
                         5 Marca 2025
                        
                    
                                                            
                        
                         30 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025