Inventory
Important Safety Instructions
Inspect the package contents upon receipt. Notify the carrier and
dealer if there is any damage.
SAVE THESE INSTRUCTIONS - This section contains important instructions that
should be followed during installation and maintenance of the UPS and batteries.
Connect the UPS power cable directly to a wall outlet.
The UPS is intended for indoor use only.
CAUTION: A battery can present a risk of electric shock and burns by high
short-circuit current.
CAUTION: Failed batteries can reach temperatures that exceed the burn thresholds
for touchable surfaces.
Do not operate the UPS in direct sunlight, in contact with fluids, or where there is
excessive dust and humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
ventilation.
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Connect Equipment
Battery Backup + Surge Protection Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to AC power. Battery backup outlets receive
power from the battery for a limited period of time when a power outage, or brownout
condition occurs. Battery backup outlets provide protection from power surges or
spikes. Connect a computer, monitor and other peripheral devices to these outlets.
Surge Protection Outlets
Surge protection outlets provide protection to connected equipment when the
Back-UPS is connected to AC power, and is switched on or off. Surge protection
outlets provide protection from power surges or spikes. Connect peripheral devices
(such as printer, scanner, etc.) that do not need to remain on during power outages or
AC problems to the surge protection outlets.
USB charging port
The USB port provides a maximum of 1.5A DC power. The USB port will provide
power when the unit is on AC and on battery.
Turn On the Back-UPS
Press the POWER button located on the top of the Back-UPS. The POWER button will
illuminate green and a single short beep will indicate that the Back-UPS is on and
providing protection for connected equipment.
The Back-UPS battery charges fully during the first 24 hours while connected to AC
power. The Back-UPS battery will charge regardless of whether the Back-UPS is
switched on or off as long as it is connected to AC power. The UPS will have full
runtime capability after the initial 24 hour charging period.
If the red Building Wiring Fault indicator (located on the end near the power cord) is
lit, your building wiring may present a shock hazard that should be corrected by a
qualified electrician.
Turn Off the Back-UPS
To turn off the Back-UPS, press the POWER button for at least 2 seconds. At the first
beep, release the button and the UPS will turn off. A 2 second delay has been added to
mitigate unintentional contact with the POWER button.
Quick Mute
The Back-UPS is able to temporarily mute user correctable alarms such as: On
Battery, Battery disconnected and Overload.
During such alarms, a short press (less than 2 seconds) of the POWER button will
temporarily mute the alarm until the condition has been reset. A short double beep will
confirm that Quick Mute has been activated. Pressing the POWER button for more than
2 seconds will turn off the UPS.
Other critical events such as Battery replacement and Charger notification can not be
temporarily muted. The unit in these cases must be turned off.
On Battery Indicator Modes
This Back-UPS has 3 On Battery Indicator modes provided that the UPS is turned on.
To configure an On Battery Indicator mode, hold down the POWER button and wait for
the third beep. At the third beep the POWER button will cycle red / green. Release the
POWER button and its color will indicate the mode the UPS is in. Press the POWER
button to cycle through each mode. See the table below for the mode selection colors.
Once the mode has been selected, wait 5 seconds and the setting will be committed to
the UPS.
PowerChute Personal Edition Software
Overview
Use PowerChute Personal Edition software to configure the UPS settings, protect your
computer and other equipment during a utility power outage. During a power outage,
PowerChute will save any open files on your computer and shut it down. When utility
power is restored, it will restart the computer.
Note: PowerChute is only compatible with a Windows operating system. If you are
using Mac OSX, use the native shutdown feature to protect your system. See the
documentation provided with your computer.
Installation
Use the USB cable to connect the Data port on the UPS to the USB port on your
computer. Download PowerChutePersonal Edition Software from www.apc.com/
pcpe. Select the appropriate operating system and follow directions to download the
software.
Status Indicators
CAUTION
RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
Replace the battery at least every 5 years or at the end of its service life,
whichever is earlier.
Replace the battery immediately when the Easy UPS indicates battery
replacement is necessary.
Replace batteries with the same number and type of batteries as originally
installed in the equipment.
Replace the battery immediately when the UPS indicates a battery over-
temperature condition, or when there is evidence of electrolyte leakage.
Power off the Easy UPS, unplug it from the AC input, and disconnect the
batteries. Do not operate the Easy UPS until the batteries have been
replaced.
Failure to follow these instructions can result in minor or moderate
injury and equipment damage.
Remove the “Stop! Connect the Battery”
label that covers the outlets.
Press the battery compartment cover
release tabs located on the underside of the
unit. Slide the battery cover off.
Connect the battery cable securely to the
battery terminal. It is normal for small sparks
to be seen when the battery cable is connected
to the battery terminal.
Reinstall the battery compartment
cover. Be sure that the release tabs lock
into place.
bu446a
bu447a
bu448a
bu449a
bu450a
bu451f
POWER
Button
USB Charger
Battery Backup + Surge
Protection Outlets
Surge Protection
Outlets
bu452e
Building
Wiring
Fault
USB Data Port (PowerC hute)
AC Power
Inlet
Circuit
Breaker
Mode Visual
Indicator Audible Indicator Mode Selection
Color
Quiet Alarm
(default)
The POWER
button is solid
green and
flashes twice
every 2 seconds
until Low
Battery
notification
where it will
flash green in
rapid
succession.
No alarm until Low Battery
notification where the alarm beeps
twice every 30 seconds
Flashing green
No Alarm No alarm while the UPS is On
Battery
Flashing red
Full Alarm Alarm sounds 4 beeps every 30
seconds until Low Battery
notification where the alarm beeps
every half second. As the UPS
shuts down it sounds one beep
every 4 seconds
Flashing amber
Status Power Button
illumination
Audible
Indicator On
Audible
Indicator
Terminates
Power On
The Back-UPS is supplying AC
power to connected equipment.
Solid green None N/A
On Battery
Back-UPS supplying battery
power to battery backup outlets.
Solid green and
flashes twice
every 2 seconds.
The audible
alarm
depends on
the On
Battery
Indicator
mode setting.
See the On
Battery
Indicator
Modes
section for
full details.
Beeping stops
when AC power is
restored or the
Back-UPS is
turned off.
Applies only to
modes where the
on battery alarm is
audible.
Low Battery notification
The Back-UPS is supplying
battery power to the battery
backup outlets and the battery is
near a total discharge state.
Flashes green in
rapid succession.
Low Battery shutdown
The battery has been completely
discharged while the Back-UPS
is on battery, the UPS will shut
down.
None - AC power is
restored
- AC is not
restored within 32
seconds
- The Back-UPS is
turned off.
Sleep Mode
The UPS has shut down and will
“awakenonce AC power is
restored
None None N/A
Replace Battery
• The battery is disconnected.
• The battery needs to be charged, or
replaced.
• Flashes red only.
• Alternates green-
red
Constant tone
Constant tone
Back-UPS is
turned off
Overload Shutdown
An overload condition has
occurred in one or more of the
battery backup outlets while the
Back-UPS is operating on battery
power.
None Constant tone Back-UPS is
turned off
USB Detected Fault
A short circuit has been detected
or an error has occurred.
Alternates green-
amber
None N/A
User Manual Back-UPS BN600U1