PRO SWITCHING SYSTEM PLUS
Part Numbers
Rack Mount Chassis SM960A 4U 19” Chassis
SNMP Controller Card SM962A Includes MIB file & SwitchCenter GUI
RS232 Controller Card SM963A
Logic-only Controller Card SM964A
RJ45 CAT-5 A/B Switch Card SM978A
RJ45 CAT-6 A/B Switch Card SM979A Supports 10 GbE
RJ45 CAT-6 Dual-Port A/B Switch Card SM980A Supports 10 GbE
Video - F Connector, 75 Ohm A/B Switch Card SM976A
DB25 A/B Switch Card SM965A Switches All 25 Leads
DB9 A/B Switch Card SM966A Switches All 9 Leads
DB15 A/B Switch Card SM967A Switches All 15 Leads
Fiber Optic A/B Switch Card - SC SM977A-SC Full Duplex, Multimode Fiber
Fiber Optic A/B Switch Card - ST SM977A-ST Full Duplex, Multimode Fiber
AC Power A/B Switch Card - 1IN/2OUT (120 VAC) SM968A
AC Power A/B Switch Card - 1IN/2OUT (240 VAC)
SM970A
AC Power A/B Switch Card - 1IN/2OUT (120 VAC)
SM969A with SNMP reporting
AC Power A/B Switch Card - 1IN/2OUT (240 VAC)
SM971A with SNMP reporting
AC Power A/B Switch Card - 2IN/1OUT (120 VAC) SM973A with SNMP reporting
Blank Rear Panel SM981 Covers 1 empty slot in Chassis
External Power Supply Module SM961A - PS 1 per chassis, or 2 for redundant power
Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com
CUSTOMER
SUPPORT
INFORMATION

PRO SWITCHING SYSTEM PLUS Page 2 of 24
Federal Communications Commission (FCC) Statement
This equipment generates, uses, and can radiate radio frequency energy and if not
installed and used in accordance with the instruction manual, may cause interference to
radio communications. It has been tested and found to comply with the limits for a Class
A computing device in accordance with the specifications in Subpart J of Part 15 of FCC
rules, which are designed to provide reasonable protection against such interference when
the equipment is operated in a commercial environment. Operation of this equipment in
a residential area is likely to cause interference, in which case the user at his own expense
will be required to take whatever measures may be required to correct the interference.
Contents
Chapter Page
1. Specifications 3
2. Introduction 4
3. Configuration 5
4. Installation 8
5. Operation 9
6. SNMP/Web Setup 13
7. Console Commands 14
8. Web Interface 18
9. MIB Path Summary 20

PRO SWITCHING SYSTEM PLUS Page 3 of 24
1. Specifications
Connectors:
RJ45 A/B SWITCH CARDS – SM978A & SM979A (3) RJ45 connectors; SM980A (6) RJ45 connectors
FIBER OPTIC A/B SWITCH CARD – SM977A-SC (3) duplex SC; SM977A-ST (6) ST
DB25 A/B SWITCH CARD – (3) DB25 female connectors
DB15 A/B SWITCH CARD – (3) DB15 female connectors
DB9 A/B SWITCH CARD – (3) DB9 female connectors
CONTROLLER CARD – (1) RJ45, (2) RJ11, (2) Two-Position DC Power Entry, (2) Two-Position Alarm Contact
Terminal Block
AC POWER A/B SWITCH CARD – 1IN 2OUT CARDS (1) IEC320 male and (2) IEC320 female; 2IN 1 OUT
CARD (2) IEC320 male and (1) IEC320 female
Indicators:
A/B SWITCH CARDS – (2) LED, one for A, one for B
CONTROLLER CARD – (3) LED, two for power, one for status, (2) Alarm Relay Contacts
Switches:
A/B SWITCH CARDS – (1) momentary toggle switch
CONTROLLER CARD – (1) momentary toggle switch, (2) 8-position dipswitch, (1) momentary push-button switch
4U RACK – (1) key-lock switch
Power:
RJ45, DB9 & DB15 A/B SWITCH CARDS – 12 VDC, 15 mA normal, additional 80 mA while switching.
FIBER OPTIC A/B SWITCH CARD – 12 VDC, 15 mA in A position, 95 mA max in B position, additional 20 mA
while switching.
DB25 & AC POWER A/B SWITCH CARDS – 12 VDC, 15 mA normal, additional 200 mA while switching.
CONTROLLER CARD – 12 VDC, 50 mA normal, additional 30 mA while switching, and an additional 250 mA
with SNMP module.
The 4U rack may be powered with one or two external 12 VDC, 5 A, regulated supplies.
The external power supply has an IEC input socket, for 100 – 240 VAC, 47 – 63 Hz INPUT, with a 12 VDC, 5 A,
regulated OUTPUT.
Environment:
TEMPERATURE 0° to 50° C operating, -40° to 70° C non-operating
HUMIDITY 0 to 95% non-condensing
ALTITUDE 40,000 ft maximum
Rack Size:
RACK – 7.0” H x 19” W x 6.5” D (not including handles and connectors)
RJ45 A/B SWITCH CARDS – one slot (0.937 inches wide)
FIBER OPTIC A/B SWITCH CARDS – one slot (0.937 inches wide)
DB9, DB15, DB25 A/B SWITCH CARDS – one slot (0.937 inches wide)
CONTROLLER CARDS – one slot (0.937 inches wide)
AC POWER A/B SWITCH CARDS – two slots (1.874 inches wide)
The Pro Switching System Plus rack has 18 slots. Slot 18 is reserved for future expansion.
Specyfikacje produktu
Marka: | Black Box |
Kategoria: | Spacerowicz |
Model: | Pro Switching System Plus SM977A-ST |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Black Box Pro Switching System Plus SM977A-ST, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Spacerowicz Black Box
30 Sierpnia 2024
22 Sierpnia 2024
8 Sierpnia 2024
4 Lipca 2024
Instrukcje Spacerowicz
- Spacerowicz Hayward
- Spacerowicz GB
- Spacerowicz Baninni
- Spacerowicz Ingenuity
- Spacerowicz Qtus
- Spacerowicz Chipolino
- Spacerowicz Edwards & Co
- Spacerowicz Phil & Teds
- Spacerowicz Silver Cross
- Spacerowicz Emmaljunga
- Spacerowicz Caretero
- Spacerowicz Eufy
- Spacerowicz Leclerc
- Spacerowicz ABC Design
- Spacerowicz OBaby
Najnowsze instrukcje dla Spacerowicz
4 Kwietnia 2025
5 Marca 2025
5 Marca 2025
24 Lutego 2025
7 Lutego 2025
6 Lutego 2025
6 Lutego 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025