Downdraft Ventilators
Page 1
WARNING
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING:
1.  Use this unit only in the manner intended by the manufacturer. If you 
have questions, contact the manufacturer at the address or telephone 
number in the warranty.
2.  Before servicing or cleaning unit, switch power off at service panel 
and lock the service disconnecting means to prevent power from be-
ing switched on accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning device, such 
as a tag, to the service panel.
3.  Installation work and electrical wiring must be done by a qualified 
person(s) in accordance with all applicable codes and standards, 
including fire-rated construction codes and  standards.
4.  Sufficient air is needed for proper combustion and exhausting of 
gases through the flue (chimney) of fuel burning equipment to prevent 
backdrafting. Follow the heating equipment manufacturer’s guideline 
and safety standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local 
code authorities.
5.  When cutting or drilling into wall or ceiling, do not damage electrical 
wiring and other hidden utilities.
6.  Ducted fans must always be vented to the outdoors.
7.  To reduce the risk of fire, use only metal ductwork.
8.  Do not install this product with the activating switch directly behind 
a burner or element. Minimum distance between the switch and the 
edge of the burner should be 4 inches.
9.  Loose-fitting or hanging clothing should never be worn when operating 
this appliance. They may be ignited by burners/elements on cooktop.
10.  Children should not be left alone or unattended in the area where this 
appliance is in use.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a)  Never leave surface units unattended at high settings.   
Boilovers cause smoking and greasy spillovers that may   
ignite. Heat oils slowly on low or medium settings.
b)  Always turn hood ON when cooking at high heat or when   
cooking flaming foods.
c)  Clean ventilating fans frequently. Grease should not be   
allowed to accumulate on fan or filter.
d)  Use proper pan size. Always use cookware appropriate   
for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF 
A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING
a
:
1.  SMOTHER FLAMES with a close-fitting lid, cookie sheet,   
or metal tray, then turn off the burner. BE CAREFUL TO   
PREVENT BURNS. If the flames do not go out immedi  
ately, EVACUATE AND CALL THE FIRE DEPARTMENT.
2.  NEVER PICK UP A FLAMING PAN - You may be burned.
3.  DO NOT USE WATER, including wet dishcloths or towels  
  - a violent steam explosion will result.
4.  Use an extinguisher ONLY if:
A.  You know you have a Class ABC extinguisher, and you   
  already know how to operate it.
  B.  The fire is small and contained in the area where it     
started.
  C.  The fire department is being called.
  D.  You can fight the fire with your back to an exit.
a
 Based on “Kitchen Firesafety Tips” published by NFPA.
MODEL  WIDTH  BLOWER
RMDD3004  30"  500 cfm Internal
RMDD3604  36"  500 cfm Internal
RMDD4804  48"  500 cfm Internal
RMDD3004EX  30"  Models 331H, 332H, 335, 336 HLB3, HLB6, HLB9, and HLB11 External (purchase separately)
RMDD3604EX  36"  Models 331H, 332H, 335, 336 HLB3, HLB6, HLB9, and HLB11 External (purchase separately)
RMDD4804EX  48"  Models 331H, 332H, 335, 336 HLB3, HLB6, HLB9, and HLB11 External (purchase separately)
WARNING - To reduce the risk of burns or ignition of clothing by reaching across burners, the downdraft remote control MUST   
be mounted in the countertop - at least 4" from the burners. See "INSTALL COOKTOP" section on page 8.
!
INSTALLER:  
Save this manual for Electrical 
Inspector and Homeowner to use.
NOTE: Model RMDDRBK Remote Up/Down 
Control sold separately.
CAUTION
1.  For indoor use only.
2.  For general ventilating use only. Do not use to exhaust hazardous or 
explosive materials and vapors.
3.  To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
4.  Clean filters and grease-laden surfaces frequently.
5.  Do not repair or replace any part of this appliance unless specifically 
recommended in this manual. All other servicing should be done by 
a qualified technician.
6.  Please read specification label on product for further information and 
requirements.
7.  To reduce the risk of fire and electric shock, install this downdraft only 
with Rangemaster blower models shown below. Other blowers cannot 
be substituted. (blowers sold separately).
MODEL  WIDTH  BLOWER
RMDD3004  30"  500 cfm Internal
RMDD3604  36"  500 cfm Internal
RMDD4804  48"  500 cfm Internal
RMDD3004EX  30"  External, Model 331H, 332H, 335, 336,  
  HLB3, HLB6, HLB9, y HLB11 (purchase  
  separately)
RMDD3604EX  36"  External, Model 331H, 332H, 335, 336,  
  HLB3, HLB6, HLB9, y HLB11 (purchase  
  separately)
RMDD4804EX  48"  External, Model 331H, 332H, 335, 336,  
  HLB3, HLB6, HLB9, y HLB11 (purchase  
  separately)
Register your product online at: www.broan.com/register
Specyfikacje produktu
| Marka: | Broan | 
| Kategoria: | Czytać | 
| Model: | RMDD4804 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Broan RMDD4804, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Czytać Broan
                        
                         29 Maja 2024
                        
                    
                                                            
                        
                         28 Maja 2024
                        
                    
                                                            
                        
                         27 Maja 2024
                        
                    
                                                            
                        
                         24 Maja 2024
                        
                    
                                                            
                        
                         22 Maja 2024
                        
                    
                                                            
                        
                         7 Maja 2024
                        
                    
                                                            
                        
                         6 Maja 2024
                        
                    
                                                            
                        
                         5 Maja 2024
                        
                    
                                                            
                        
                         4 Maja 2024
                        
                    
                                                            Instrukcje Czytać
- Kernau
- Bosch
- Matsui
- Electrolux
- Lamona
- Samsung
- Thermador
- Belling
- Baumatic
- V-Zug