Instrukcja obsługi Cotech 36-1761
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Cotech 36-1761 (4 stron) w kategorii Ulga. Ta instrukcja była pomocna dla 40 osób i została oceniona przez 20.5 użytkowników na średnio 4.5 gwiazdek
                        Strona 1/4
                    
                    
                    
ENGLISH
Ver. 200806
Spotlight Kit 
18-2387/36-1761, 18-2388/36-1762, 18-2389/36-1763
Please read the entire instruction manual before using the product 
and save it for future reference. We apologise for any text or 
photographic errors and any changes of technical data. If you have 
any questions concerning technical problems please contact our 
Customer Service Department.
1. Safety
-  Read all the instructions before you install and turn on the lights. 
-  The wiring should meet the required standards. If you are not 
sure about anything, contact a qualied electrician.
-  Make sure that the electrical specications are in accordance with 
your installation. The circuit must be protected by a fuse on 10 A. 
-  The minimum area on the connection lead to the electrical 
current is 1.5 mm².
-  Before drilling in the ceiling, check for possible interferences 
such as power lines. 
-  The metal piece that is used to show the spotlight in adjusted posi-
tion in the box should be removed and not be used at installation. 
-  Always turn off the power before mounting, connecting 
or maintenance.
-  Follow the instructions regarding minimum and maximum values. 
Explanation of symbols
2. Contents
-  3 halogen lights 12 V/20 W incl. 1.5 cables
-  Electronic transformer 
-  1.5 m power lead
3. Installation
3.1 Before getting started
Tools required:
4. Care and Maintenance
-  Always turn off the power before carrying out any maintenance.
-  You may only replace the halogen light – any other repairs 
should be carried out by a qualied electrician.
-  Only use halogen lights that match the specications.
-  Warning: Using accessories other than those recommended in 
these instructions may lead to personal injury.
-  This light kit is approved according to current standards. 
Repairs must only be carried out by qualied personnel using 
original spare parts.
-  The transformer has a short circuit and surge protector that 
shuts it off automatically if necessary. When the short circuit or 
overload has been rectied the transformer starts again. 
-  The transformer has a thermal fuse which cuts the power if 
overheated to prevent further damage. 
4.1 Changing a light
1.  Turn off the electricity.
2.  Wait until the light has cooled.
3.  Remove the spring that the light is connected with. 
4.  Remove the old light and replace it with a new. 
5.  Secure the light with the spring and then turn the power on again. 
4.2 Cleaning
1.  Cut the power before cleaning. 
2.  Wait until the light has cooled.
3.  Clean the visible part of the light and the metal edge with 
a lightly moistened cloth. 
4.  Never use alcohol, solvent or similar agents to clean the light.
Disposal
When it is time to dispose of the product, dispose of it according 
to your local ordinances. If you are unsure please contact your 
municipality.
Specications
Properties
External measurements  82 mm
Drill hole  74 mm
Minimum mounting height  150 mm
Minimum distance in between 2 lights  300 mm
Minimum distance in between light and wall  100 mm
Minimum distance to ammable surface  500 mm
Electrical Specications
Transformer  35-105 W dimmable 
Primary voltage transformer  230 V AC, 50 Hz, cosØ=0,99
Secondary voltage transformer  11,6 V ~ RMS Max. 8.8 A
Connecting to the power point.  Via plug
Lamp type   12 V, 20 W halogen 
  (MR16 GU5,3)
Class  IP44
Class II
Class III
Minimum distance in between light and ammable surface. 
Light source suitable for mounting on ammable surface. 
Light source which will be used with self protective 
tungsten halogen lights with built-in protective safety 
feature and safety cover. 
When it is time to dispose of the product, dispose of it 
according to your local ordinances. If you are unsure 
please contact your municipality.
3.2 Mounting 
The transformer will be mounted in a ventilated space at a safe 
distance from heat sources according to the illustration below. 
-  Always turn off the power before mounting, connecting 
or maintenance.
-  Only use included cables when connecting the light kit. 
1.  Measure the placement of the lights and 
drill a hole with the diameter 74 mm. Mount 
the transformer and pull the cables from the 
transformer before mounting the lights. 
3.  Push the side clamps and slide the frame up until the clamps 
lock in place on ceiling’s top.  
4.  Mount the next light with a minimum distance of 300 mm. 
Warning:
The light source and its transformer may under no circumstances be 
covered be insulation or similar materials. 
Recommended installation zones in bathrooms
Dimensions according to standard IEC60364-7-701.
2.  Connect the cable to the light. 
3.3 Connectors
-  Connect the lights’ plugs to the terminal block which is 
connected to the transformer. 
-  Connect the transformer to the electric outlet (230 V AC, 50 Hz) 
via a power switch. 
Distance from heat sources.
Transformer
Electric outlet
230 V~
12 V–
Transformer
Specyfikacje produktu
| Marka: | Cotech | 
| Kategoria: | Ulga | 
| Model: | 36-1761 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Cotech 36-1761, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Ulga Cotech
                        
                         1 Września 2024
                        
                    
                                                            
                        
                         1 Września 2024
                        
                    
                                                            
                        
                         31 Sierpnia 2024
                        
                    
                                                            
                        
                         31 Sierpnia 2024
                        
                    
                                                            
                        
                         30 Sierpnia 2024
                        
                    
                                                            
                        
                         27 Sierpnia 2024
                        
                    
                                                            
                        
                         26 Sierpnia 2024
                        
                    
                                                            
                        
                         26 Sierpnia 2024
                        
                    
                                                            
                        
                         26 Sierpnia 2024
                        
                    
                                                            
                        
                         25 Sierpnia 2024
                        
                    
                                                            Instrukcje Ulga
- Varytec
- Kinotehnik
- Claypaky
- Luxli
- Nordlux
- Mio
- Gemini
- Schonbek
- Ibiza Light
- Brandson
- LSC Smart Connect
- Corsair
- Beper
- Vivanco
- SSV Works
Najnowsze instrukcje dla Ulga
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         7 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025
                        
                    
                                                            
                        
                         5 Kwietnia 2025