Instrukcja obsługi Cotech 36-6078

Cotech światło 36-6078

Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Cotech 36-6078 (5 stron) w kategorii światło. Ta instrukcja była pomocna dla 15 osób i została oceniona przez 8 użytkowników na średnio 4.5 gwiazdek

Strona 1/5
UNITED KINGDOM CUSTOMER SERVICE
tel 020 8247 9300 customerservice@clasohlson.co.uk www.clasohlson.co.uk 10 13 Market Place, Kingston upon Thames, Surrey, KT1 1JZe-mail internet postal
1
2
3
4
5
Ver. 20181204
Motion Sensor Ceiling Light
Art.no 36-6078
Please read theentire instruction manual before using theproduct and then save it for future
reference. Wereserve theright for any errors in text or images and any necessary changes
made to technicaldata. Intheevent of technical problems or other queries, please contact
our Customer Services.
Safety
Installation should only be carried out by aqualified electrician.
Theproduct is only intended for indooruse.
Theproduct must be installed in accordance with current safety regulations to prevent
life-threatening accidents.
Theproduct is intended for fixed installation.
Theproduct is intended for ceiling installation.
Installation
Fixings
If thesupplied fixings are not suitable for thematerial which your ceiling is made of,
use appropriate fixings which will guarantee afirm anchorage.
Activation range
Therange is controlled by DIP switches 1, 2 and 3
10–100 % of 6m
Duration of activation after motion detection
Theactivation time is controlled by DIP switches 4, 5 and 6
5 sec – 30min
Light sensor sensitivity
Thesensitivity is controlled by DIP switches 7, 8 and 9
2–50 lux oroff
Note: Thelux values are measured with thediffuser removed.
Whenthediffuser is fitted, thelux values are somewhatlower.
The luminous flux (brightness) of the ceiling light can be adjusted by setting
the DIP switches as shown in the table.
Luminous flux (lm) Power (W) 1 2
1100 15.5 − −
800 11.5 ON −
500 7.6 ON ON
Care and maintenance
Switch off thepower to theceiling light before cleaning. Clean thelight by wiping it with asoft,
dampcloth. Useamild detergent. Neveruse solvents or strong, abrasive cleaning agents.
Responsible disposal
This symbol indicates that this product should not be disposed of with general
household waste. This applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards caused by incorrect waste
disposal, theproduct must be handed in for recycling so that thematerial can
be disposed of in aresponsible manner. When recycling your product, take it to
your local collection facility or contact theplace of purchase. They will ensure
that theproduct is disposed of in anenvironmentally sound manner.
Specifications
Only intended for indoor use (IP44).
If theplastic diffuser is damaged it must be replaced.
Minimum distance from combustible material: 0.1m.
Warning: Makesure that thepower is shut off before
starting theinstallation.
Thelight source in this product must only be replaced by
themanufacturer, aqualified service facility or aqualified
technician.
Note: Ifyou need to drill into theceiling, make sure to avoid any concealed electrical wiring.
1. Open theceiling light by twisting thediffuser anticlockwise and removingit.
2. Remove theplate holding theLED light by undoing the3retaining screws.
3. Knock out one of thepre-cut cable entries andt thecablegland.
4. Pull thepower supply cable through thecablegland.
5. Fasten theceiling light directly to theceiling using the4outermost mounting holes or
fasten it to aceiling rose using the2 innermost mountingholes.
6. Connect thepower supply cable to theterminal block as shownbelow.
7. Re-assemble theceiling light in reverseorder.
Sensor
1. Light sensor
2. LED which comes on when
thesensor is activated
3. Controls for setting
theactivation range,
duration of activation and
light sensor sensitivity.
4. Out
5. In
Light fitting
Power supply 220240 VAC,
50/60 Hz
Light source Built in LED
Power 15.5W
IP rating IP44
Colour temperature 3000K
Colour rendition Ra 80
Luminous flux 1100lm
800 lm
500 lm
Operating temperature −30°C ~ +40°C
Diam 34cm
Sensor
Recommended
installation height 2.5–6m
Detection range 12m
Sensitivity 10, 25, 50,
75 or 100 %
Lighting time 5 sec, 30 sec,
90 sec, 3min,
20min or 30min
Light sensor 2, 10, 25,
50 lux oroff
Motion sensor 0.5–3m/s
Detection angle 360º
Relay output for connecting up to 14additional
ceiling lights (36-6077), which are all activated
simultaneously.
Maxload: 800W resistive, 400W inductive
This ceiling light (36-6078) can be
interconnected with and control
multiple ceiling lights of article number
36-6077.
ON
1 2


Specyfikacje produktu

Marka: Cotech
Kategoria: światło
Model: 36-6078

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Cotech 36-6078, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje światło Cotech

Cotech

Cotech EMP701MD Instrukcja

2 Września 2024
Cotech

Cotech 36-6078 Instrukcja

2 Września 2024
Cotech

Cotech CED806 Instrukcja

1 Września 2024
Cotech

Cotech 36-6077 Instrukcja

1 Września 2024
Cotech

Cotech 36-8051 Instrukcja

1 Września 2024
Cotech

Cotech RP120W Instrukcja

1 Września 2024
Cotech

Cotech LY9601H Instrukcja

1 Września 2024

Instrukcje światło

Najnowsze instrukcje dla światło

Livarno Lux

Livarno Lux IAN 89559 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 37695 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 292044 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 279890 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 286986 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 282512 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 273535 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 280201 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 66760 Instrukcja

26 Października 2024
Livarno Lux

Livarno Lux IAN 288563 Instrukcja

26 Października 2024