Residual Current Device
with No-Volt Release Switch
Art.no 18-2032 Model EMP200-UK
32-3492 EMP200S-1
Please read theentire instruction manual before use and save it for
future reference. Wereserve theright for any errors in text or images
and for making any necessary technical changes to this document.
Ifyou should have any questions concerning technical problems
please contact our CustomerServices.
Product description
Theresidual current device’s main function is to protect people and
property if insulation failure should occur in electrical equipment.
Theresidual current device is agood complementary protection to
other safety precautions measures such as fuses and earthing.
This residual current device is anon-latching type which means that
it has ano-volt release switch which has to be reset manually after
apowercut.
For plugging directly into anearthed wall socket.
Trips at 30 mA fault current (mA = one thousandth of anampere).
Equipped with test button and indicator.
Protection class IP44 (32-3492 only).
Safety
Make sure that theelectrical socket that theproduct is plugged
into is easily accessible in case it and theconnected product need
to be quickly disconnected from themains electricity.
Do not connect products of this type to each other.
Do not cover theproduct.
Operation
Residual current device
RCDs operate by measuring thecurrent balance between thelive
and neutral conductor in acircuit. Whenacircuit operates normally,
thesupply and return currents are in balance and sum to zero. Ifthere
is afault in thecircuit (suchas dangerous current leakage through
thebody of aperson to earth), thecurrent will be out of balance and
theRCD will trip and cut off thesupply of current.
Theoperation of theRCD should be checked regularly using thetest
button.
No-volt release switch
Thebuilt-in no-volt release switch prevents theconnected electrical
device (drill, lathe, etc.) from starting again automatically after apower
cut. Theno-volt release switch must be reset by pushing the[ RESET ]
button twice after apower outage before it will allow current to
flowagain.
Use
Theresidual current device is designed to be plugged into anearthed
wall socket.
Plug theRCD into anelectrical socket and press [ RESET ]
twice in order to reset theno-voltage release switch inside before
theRCD’s socket is energized. Asmall orange dot can be seen in
theindication window above the[ RESET ] button when theRCD’s
socket is energized.
Note: Onlyplug theresidual current device into sockets where it can
be inserted with the[ RESET ] button located above thesocket. (Only
applies to theNordic countries)
Testing the RCD
1. Before theresidual current device is used it must be tested by
pushing the[ TEST ] button.
2. Theorange dot in theindication window above the[ RESET ]
button disappears when theRCD trips and cuts off thecurrent to
thesocket.
3. Reset theRCD by pressing the[ RESET ] button twice. Theorange
dot in theindicator window should be visible when theRCD has
been reset and conducts current to thesocket again.
Note: Thetest button only works when theRCD is plugged into alive
electrical socket.
Responsible disposal
This symbol indicates that this product should not
be disposed of with general household waste. This
applies throughout theentire EU. In order to prevent
any harm to theenvironment or health hazards
caused by incorrect waste disposal, theproduct must
be handed in for recycling so that thematerial can be
disposed of in aresponsible manner. When recycling
your product, take it to your local collection facility
or contact theplace of purchase. They will ensure
that theproduct is disposed of in anenvironmentally
sound manner.
Specifications
18-2032 32-3492
Type EMP200-UK EMP200S-1
Protection class ClassA ClassA
Rated voltage 220–240 VAC 220–240 VAC
Rated current 13 A16A
Apparent power
breaking capacity 3120 VA 3680VA
Tripping current 30mA 30mA
Tripping time < 30ms < 30ms
Protection class IP20 IP44
Operating temperature –25 to +40 °C –25 to +40 °C
Current draw 1.2W 1.2W
Certified by TÜV Semko
Note: Alwaysperform afunction test before connecting aload to
theresidual current device’s outlet.
Contact our customer services if thetest of theresidual current device
failed or if you suspect that it does not workproperly.


Specyfikacje produktu

Marka: Cotech
Kategoria: wyłącznik instalacyjny
Model: EMP200S-1

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Cotech EMP200S-1, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje wyłącznik instalacyjny Cotech

Cotech

Cotech EMP200S-1 Instrukcja

2 Września 2024

Instrukcje wyłącznik instalacyjny

Najnowsze instrukcje dla wyłącznik instalacyjny

Hager

Hager HTG472H Instrukcja

15 Sierpnia 2024
Hager

Hager HFD416 Instrukcja

15 Sierpnia 2024
Hager

Hager HTG471H Instrukcja

15 Sierpnia 2024
Hager

Hager HFD412 Instrukcja

15 Sierpnia 2024
Hager

Hager HFD363 Instrukcja

15 Sierpnia 2024
Hager

Hager HTG480H Instrukcja

15 Sierpnia 2024
Hager

Hager HTG474H Instrukcja

15 Sierpnia 2024
Hager

Hager HXF002H Instrukcja

15 Sierpnia 2024