CP550/ 13900/ 00/1500EPFCLCD 
User’s Manual 
K01- -030000460  
This manual contains important safety instructions. Please read and follow all instructions carefully during 
installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or 
operate your UPS. 
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker 
protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to  -energize this de
equipment, turn o and unplug the UPS. 
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does 
not sell products for life support or medical applications.   use in any circumstance that would aect DO NOT
the operation   safety of life support equipment, medical applications, or patient care. and
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is 
disconnected. 
CAUTION! To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor 
area, free of conductive contaminants. (Please see specications for acceptable temperature and humidity 
range). 
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery. There 
are no user serviceable parts inside, except for the battery. 
CAUTION! To avoid electrical shock, turn o the unit and unplug it from the AC power source before 
servicing the battery or installing a computer component. 
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of re, do not use with or near 
aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause 
the machine to short out. 
DO NOT USE THE UPS ON ANY TRANSPORTATION!    To reduce the risk of re or electric shock, do not 
use the unit on any transportation such as airplanes or ships. The eect of shock or vibration caused during 
transit and the damp environment can cause the unit to short out. 
UNPACKING 
The box should contain the following: 
(1) UPS Unit  1; (2) USB Cable x    User Manual  1;  ) Function Setup Guide x 1 ; (5 Power Cord x  1; (3)  x  (4 ) 
(Type and quantity may dier from models.) 
OVERVIEW 
The  1300/1500EPFCLCD provides automatic voltage regulation for inconsistent utility power. CP550/900/
The  900/1300/1500EPFCLCD features   Joules of surge protection, and provides battery backup CP550/ 405
during power outages. The  900/1300/1500EPFCLCD  s consistent power to your computer CP550/ ensure
system and its included software will automatically save your open les and shut down your computer 
system during a utility power loss. 
SUPPORTS Active PFC POWER SUPPLIES 
This CyberPower UPS system supports High Eciency power supplies with Active Power Factor Correction 
(Active PFC). Active PFC is used to improve the eciency of power delivery. The current US Energy Star®  
Program Requirements for Computers mandates Active PFC for all power supplies over 100 watts. 
Additionally, programs such as 80 Plus®  are often used to identify high eciency power supplies with Active 
PFC. 
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 
1.  Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral 
equipment does not exceed t 550VA/he  900VA/ VA/ . 1300 1500VA
2.  Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the 
UPS unit's rated capacity ( A/350W for CP550EPFCLCD, 550V 900VA/540W for CP900EPFCLCD, 
1300 780VA/ W for CP1300EPFCLCD,  VA/ W for CP1500EPFCLCD). If the rated unit capacities 1500 900
are exceeded, an overload condition may occur and cause the UPS unit to shut down   the circuit or
breaker to trip. 
  DESCRIPTION 
1.  Power Switch 
Used as the master on/o switch for equipment connected to the battery power supplied outlets. 
2.  Power On Indicator 
This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of 
surges and spikes. 
3.  LCD Module Display 
High resolution and intelligent LCD display shows all the UPS information with icons and messages. For 
more information, please check the “Definitions for Illuminated LCD Indicators” section. 
4.  Display Switch 
The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and 
Estimated Run Time. The toggle frequency is set to one time per 0.5 second. Press the switch to roll 
down the function menu. Pressing the switch for 2 seconds will turn the LCD display on or o while in 
AC/Utility power mode. 
5.  Silence Alarm Switch 
The toggle frequency is set to one time per 0.5 second. Press the switch to roll up the function menu. 
Holding the switch for more than 2 seconds will silence the buzzer. 
6.  Control Switch 
Press the Control switch for 3 seconds in AC/Utility Power Mode to perform a Self Test of the battery. 
7.  USB Charging Ports 
The USB Power ports provide 5V  1A power output. 2.
8.  Communication Protection Ports RJ45 
Communication protection ports will protect network cable from surge and spikes. 
9.  USB Port to PC 
This port allows connection and communication from the USB port on the computer to the UPS unit. The  
UPS communicates its status to the PowerPanel
®
 Personal Edition software. 
10. Serial Port to PC 
This port allows connection and communicat  from the DB-9 serial on the computer to the UPS unit. es
The UPS communicates its status to the PowerPanel®  Personal Edition software. 
NOTE: Only one of these two ports can be used as communication and control of the UPS unit at one 
time. 
11. Battery and Surge Protected Outlets 
The unit has several battery powered/surge suppression outlets for connected equipment to ensure 
temporary uninterrupted operation of your equipment during a power failure. Check the type and quantity 
of outlets for different models in the following table. (DO NOT plug a laser printer, paper shredder, 
copier, space heater, vacuum, sump pump or other large electrical devices into the  Battery and “
Surge Protected Outlets The power demands of these devices may overload and damage the ”. 
unit.) 
Model 
NEMA 
DE 
UK 
AU 
FR 
Outlet 
Type 
Quantity 
8 
6 
2 
4 
6 
6 
*CP900EPFCLCD-AU has 3 Battery and Surge Protected Outlets and 3 Surge protected outlets 
12. Circuit Breaker 
Located on the back of the UPS, the circuit breaker serves to provide overload and fault protection. 
13. AC Input 
Connect the AC Power cord to a properly wired and grounded outlet. 
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 
hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss 
may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC 
outlet. The unit will charge in both the on and o position. 
Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. 
The rst time you turn the UPS  , you will need to have it connected to AC power or it will not power up. on
2. If you will use the software, connect the USB cable to the USB port on the UPS. 
3. With the UPS unit o and unplugged, connect the computer, monitor, and any externally powered data 
storage device (Zip drive, Jazz drive, Tape drive, etc. )into the battery power supplied outlets. DO NOT 
plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the 
battery power supplied outlets. The power demands of these devices will overload and possibly damage 
the unit. 
4. To protect network cable, connect a network cable from the wall jack outlet to the IN jack of the UPS. Then 
connect network cable from the OUT jack on the UPS to the  mputer or network device. co
5. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is 
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. 
air conditioner, refrigerator, copier, etc. Avoid using extension cords. 
6. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will 
"beep". 
7. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, 
turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 
10 seconds. Make sure the circuit breaker is depressed and then turn the UPS on. 
8. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the 
battery will automatically recharge. 
9. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
10. To store your UPS for an extended period, cover it and store with the battery fully 
charged. Recharge the battery every three months to ensure battery life. 
11.  
CyberPower’s Green Commitment 
CyberPower is dedicated to the development of green products, and has adopted   
Green practices throughout its business, including: membership in Climate Savers   
Computing Initiative (CSCI), accordance with the Restriction on Hazardous   
Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols,   
as well as ISO 14001 and IECQ QC080000. CyberPower pledges to provide the   
advanced energy solution for the environment and become a leading eco-friendly   
organization in the UPS industry. 
Reduce Energy Cost with GreenPower UPS
TM
 Technology 
CyberPower’s goal is not only to provide eco-friendly products but also to bring the best value for consumers. 
The advanced energy-saving design improves the operating efciency and eliminates waste energy 
consumption  As a result, consumers will enjoy signicant energy cost savings with the adoption of.  
GreenPower UPS
TM
 technology. 
BASIC OPERATION 
INSTALLING YOUR UPS SYSTEM 
IMPORTANT SAFETY INSTRUCTIONS 
BATTERY REPLACEMENT 
HARDWARE INSTALLATION GUIDE 
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY 
CP550/900EPFCLCD 
CP1300/1500EPFCLCD 
Specyfikacje produktu
| Marka: | CyberPower | 
| Kategoria: | UPS | 
| Model: | CP1500EPFCLCD | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CP1500EPFCLCD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS CyberPower
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         30 Grudnia 2025
                        
                    
                                                            Instrukcje UPS
- LevelOne
- FSP/Fortron
- Schneider
- Phoenix Contact
- Avocent
- HP
- Minuteman
- Maruson
- Atlantis Land
- Block
- Lenovo
- FSP
- Puls Dimension
- AEG
- Gembird
Najnowsze instrukcje dla UPS
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025