OVERVIEW
The CP825AVRLCDG/CP685AVRLCDG/
CP800AVR/CP685AVRG provides complete 
power protection from utility power that is 
not always consistent. The CP825AVRLCDG/
CP685AVRLCDG/CP800AVR/CP685AVRG 
features 1030 Joules of surge protection. The 
unit provides long lasting battery backup 
during power outages with maintenance free 
batteries. The CP825AVRLCD/CP685AVRLDG/
CP800AVR/CP685AVRG ensures consistent 
power to your computer system and includes 
software that will automatically save your 
open files and shutdown your computer sys-
tem during a utility power loss.
HOW TO DETERMINE THE POWER REQUIRE-
MENTS OF YOUR EQUIPMENT 
1.  Ensure that the equipment plugged  
into the UPS does not exceed the UPS 
unit’s rated capacity (825VA/450W for 
CP825AVRLCDG, 800VA/450W  
for CP800AVR, 685VA/390W for 
CP685AVRLCDG, CP685AVRG). If the rated 
capacities of the unit are exceeded, an 
overload condition may occur and cause 
the UPS unit to shut down or the circuit 
breaker to trip.
2.  There are many factors that can aect 
the amount of power that your electronic 
equipment will require. For optimal system 
performance keep the load below 80% of 
the unit’s rated capacity.
HARDWARE INSTALLATION GUIDE 
1.  Your new UPS 
may be used 
immediately 
upon receipt. 
However, after 
receiving a 
new UPS, to ensure the battery’s maximum 
charge capacity, it is recommended that 
you charge the battery for at least 8 hours. 
Your UPS is equipped with an auto-charge 
feature. When the UPS is plugged into an AC 
outlet, the battery will automatically charge 
whether the UPS is turned on or turned o. 
Note: This UPS is designed with a safety fea-
ture to keep the system from being turned 
on during shipment. The first time you turn 
the UPS on, you will need to have it connect-
ed to AC power or it will not power up.
2.  With the UPS unit turned o and un-
plugged, connect your computer, monitor, 
and any other peripherals requiring battery 
backup into the battery power supplied 
outlets. Plug the other peripheral equip-
ment (eg. printer, scanner, speakers, etc.) 
into the full-time surge protection outlets. 
DO NOT plug a laser printer, paper shred-
der, copier, space heater, vacuum cleaner, 
sump pump, or other large electrical device 
into the “Battery and Surge Protected Out-
lets”. The power demands of these devices 
will overload and possibly damage the unit.
3.  Plug the UPS into a 2-pole, 3-wire grounded 
receptacle (wall outlet). Make sure the wall 
branch outlet is protected 
by a fuse or circuit break-
er and does not service 
equipment with large 
electrical demands (e.g. 
air conditioner, refrigerator, copier, etc.). 
The warranty prohibits the use of extension 
cords, outlet strips, and surge strips in con-
junction with the UPS unit.
4.  Press the power switch to turn the unit on. 
The Power On indicator light will illuminate 
green and the unit will “beep” once.
5.  If an overload is detected, an audible alarm 
will sound and the unit will emit one long 
beep. To correct this, turn the UPS o and 
unplug at least one piece of equipment 
from the battery power supplied outlets. 
Make sure the circuit breaker is depressed 
and then turn the UPS on.
6.  To maintain optimal battery charge,  
leave the UPS plugged into an AC outlet  
at all times.
7.   To store the UPS for an extended period 
of time, cover it and store with the battery 
fully charged. While in storage, recharge 
the battery every three months to ensure 
optimal battery life.
8.  Ensure the wall outlet and UPS are locat-
ed near the equipment being attached for 
proper accessibility.
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400  |  Shakopee, MN 55379  |  CyberPowerSystems.com
AVR UPS SERIES
CP825AVRLCDG / CP685AVRLCDG / CP800AVR / CP685AVRG
USER MANUAL
FEATURES
1.  Power Switch
2.  Power On Indicator 
3.  Mode Switch  
For CP825AVRLCDG / CP685AVRLCDG 
4.  Fault Indicator
5.  Mute Button  
For CP800AVR / CP685AVRG
6.  LCD module display  
For CP825AVRLCDG / CP685AVRLCDG
7.  Battery and Surge Protected Outlets
8.  Full-Time Surge Protection Outlets
9.  USB Port
10.  Communication Protection Ports 
For CP825AVRLCDG
11.  Serial Port
12.  Circuit Breaker and Reset
13.  Ground Screw
14.  Outlets Designed for AC Adapters
Thank you for purchasing a CyberPower product.  This UPS is designed to provide unsurpassed 
power protection, operation, and performance during the lifetime of the product. Please take 
a few minutes to register your product at: www.CyberPowerSystems.com/registration. Regis-
tration certifies your product’s warranty, confirms your ownership in the event of a product loss 
or theft, and entitles you to free technical support. Register your product now to receive the 
benefits of CyberPower ownership.
CAUTION!  To prevent the risk of fire or  
electric shock, install in a temperature and 
humidity controlled indoor area free of  
conductive contaminants. (Please see  
specifications for acceptable temperature  
and humidity range). 
CAUTION! To reduce the risk of electric shock, 
do not remove the cover except to service the 
battery. Turn o and unplug the unit before
servicing the batteries. There are no user ser-
viceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be 
energized by the battery even when the AC 
input power is disconnected.
CAUTION! The UPS must be connected to an 
AC power outlet with fuse or circuit breaker 
protection. Do not plug into an outlet that is 
not grounded. If you need to de-energize this 
equipment, turn o and unplug the unit.
CAUTION! To avoid electric shock, turn o the 
unit and unplug it from the AC power source 
before connecting equipment to the unit.
CAUTION! To reduce the risk of fire, connect 
only to a circuit provided with 20 amperes 
maximum branch circuit over current protec-
tion in accordance with the National Electric 
Code, ANSI/NFPA 70.
CAUTION! Not for use in a computer room as 
defined in the Standard for the Protection of 
Electronic Computer / Data Processing Equip-
ment, ANSI/NFPA 75.
CAUTION! Do not dispose of batteries in a fire. 
The batteries may explode.
CAUTION! Do not open or mutilate batteries. 
Released electrolyte is harmful to the skin and 
eyes. It may be toxic.
DO NOT USE FOR MEDICAL  
OR LIFE SUPPORT EQUIPMENT!  
CyberPower Systems does not sell products 
for life support or medical applications. DO 
NOT use in any circumstance that would aect 
operation and safety of life support equip-
ment, any medical applications or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS!  
To reduce the risk of fire or electric shock, do 
not use with or near an aquarium. Condensa-
tion from the aquarium can cause the unit to 
short out.
DO NOT USE THE UPS  
ON ANY TRANSPORTATION!  
To reduce the risk of fire or electric shock, do 
not use the unit on any transportation such 
as airplanes or ships. The eect of shock or 
vibration caused during transit and the damp 
environment can cause the unit to short out.
PRODUCT REGISTRATION
IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to 
unpack, install, or operate your UPS.
INSTALLING YOUR UPS SYSTEM  - continued
UNPACKING
Inspect the UPS upon receipt.  
The box should contain the following:
(a) UPS unit  
(b) User’s manual  
(c) USB A+B type cable  
PowerPanel® Personal software is  
available on our website. Please visit  
www.cyberpowersystems.com and go  
to the Software Section for a free download.
AUTOMATIC VOLTAGE REGULATOR
The CP825AVRLCDG/CP685AVRLCDG/
CP800AVR/CP685AVRG stabilizes inconsistent 
utility power to nominal levels that are safe for 
equipment. Unstable utility power can be dam-
aging to important data and hardware.  
With Automatic Voltage Regulation (AVR), 
damaging voltage levels 
are corrected to safe 
levels. AVR automatically 
increases low utility power 
to a consistent and safe 
110/120 volts. 
BASIC OPERATION
INSTALLING YOUR UPS SYSTEM
1.  Power Switch: 
Used as the master on/o switch for equip-
ment connected to the battery power sup-
plied outlets. To turn the UPS ON, press the 
power button for approximately 2 seconds 
- you will hear a constant tone (1 second) - 
and release after a short beep. 
To turn the UPS OFF, press the power 
button for approximately 2 seconds - you 
will hear a constant tone (1 second) - and 
release after two short beeps. 
Alarm setting (For CP825AVRLCDG/
CP685AVRLCDG): The audible alarm can 
be turned O or On by double clicking 
the POWER button. The default setting is 
for the Alarm On. To turn the Alarm O, 
double click the button. You will hear two 
short beeps when the Alarm is turned o. 
To turn the Alarm back On, double click the 
button. You will hear a single short beep 
when the Alarm is turned on. *When the 
Alarm is turned O, there will be no audible 
notification when the UPS reaches a low 
battery state.
2.  Power On Indicator: 
This LED is illuminated when the utility 
power is normal and the UPS outlets are 
providing power, free of surges and spikes.
3.  Mode Switch  
(For CP825AVRLCDG/CP685AVRLCDG): 
Press the Mode Switch for approximately 
3 seconds to enter setup mode to view 
options: Utility High/low Voltage range, 
sensitivity setup, LCD sleep ON/OFF, bat-
tery test, buzzer ON/OFF, and low battery 
alarm. When an option is selected, wait for 
8 seconds for the setting to be confirmed. 
After the setting has been confirmed the 
LCD screen will leave setup mode and go 
back to status display. If there is no action 
for 8 seconds during setup, the LCD will 
also leave setup mode and go back to the 
status display.
4.  Fault Indicator: 
This LED is illuminated if there is a problem 
with the UPS.
5.  Mute Button  
(For CP800AVR/CP685AVRG):
Press the button for 2 seconds to enable 
the audible alarm (beeps once) or disable 
(beeps twice) the audible alarm.
6.  LCD module display  
(For CP825AVRLCDG/CP685AVRLCDG): 
LCD display shows all the UPS information 
using icons and messages. For more infor-
mation please review the “Definitions for 
Illuminated LCD Indicators” section.
7.  Battery and Surge Protected Outlets: 
The unit has four battery powered and 
surge protected outlets to ensure tempo-
rary uninterrupted operation of your equip-
ment during a power failure.           
8.  Full-Time Surge Protection Outlets: 
The unit has four surge suppression outlets.
9.  USB Port: 
The USB port allows connection and com-
munication between the USB port on the 
computer and the UPS unit.
10. Communication Protection Ports  
(For CP825AVRLCDG): 
Communication protection ports, bidirec-
tional, will protect a 10/100/1000 Ethernet 
connection (RJ45).
11. Serial Port: 
Serial Port allow for bi-directional commu-
nication among the UPS and the comput-
er.The UPS can control the computer’s 
shutdown in case of an emergency, and at 
the same time, the computer can monitor 
the UPS and alter its various programmable 
parameters.
12. Circuit Breaker and Reset: 
Located on the side of the UPS, the  
circuit breaker provides overload and  
fault protection.
13. Ground Screw: 
The ground screw is used for any  
equipment that needs a chassis ground 
connection.
14. Outlets Designed for AC Adapters: 
The UPS unit has four widely-spaced out-
lets. AC power adapters can be plugged 
into the UPS without overlapping or block-
ing adjacent outlets. 
2
3 4
CP825AVRLCDG
CP685AVRLCDG
CP800AVR
CP685AVRG
Specyfikacje produktu
| Marka: | CyberPower | 
| Kategoria: | UPS | 
| Model: | CP685AVRG | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower CP685AVRG, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS CyberPower
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         30 Grudnia 2025
                        
                    
                                                            Instrukcje UPS
- East
- Eaton
- Altronix
- V7
- Vanson
- Siemens
- Atlantis Land
- PowerWalker
- Conceptronic
- FSP
- Minuteman
- Maruson
- Lenovo
- Bxterra
- Schneider
Najnowsze instrukcje dla UPS
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025