UT650/850/1050EI  User’s  Manual                                                      K01-C000248-02 
IMPORTANT SAFETY INSTRUCTIONS 
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this 
manual thoroughly before attempting to unpack, install, or operate your UPS. 
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the 
specifications for the acceptable temperature and humidity range.) 
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit 
near heat emitting appliances such as space heaters or furnaces. 
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS. 
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit. 
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. 
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep 
unauthorized personnel away from batteries. 
 INSTALLING YOUR UPS SYSTEM   
UNPACKING
The box should contain the following: (1) UPS Unit x1; (2) User Manual x1; (3) Output Cable x 1 
HARDWARE INSTALLATION GUIDE
1.  Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery's 
maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into 
an AC outlet. The unit will charge in both the on and off position. 
2.  With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive, 
etc. into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device 
into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit. 
3.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does 
not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords. 
4.  Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will "beep". 
5.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece 
of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on. 
6.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
7.  To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery 
life. 
BASIC OPERATION 
1.  Power Switch 
Press the switch for 2 seconds to turn the UPS ON or OFF. 
Alarm setting: The audible alarm can be turned OFF or ON by quickly pressing the POWER button twice.
The default setting is for the Alarm On. To turn the Alarm Off, quickly press the power button twice. 
You will hear two short beeps when the Alarm is turned off. To turn the Alarm back on,   
quickly press the power button twice. You will hear a single short beep when the Alarm is turned on. 
2.  Led Indicators    This LED is illuminated when the UPS is working. 
3.  Input Power Cord    Connect to utility power.   
4.  AC outlet 
The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a power failure and against surges and spikes. 
5.  Communication Protection Ports              Communication protection ports will protect any standard modem, fax, telephone line, or network cable. 
6.  Input Circuit Breaker    The circuit breaker provides overload protection. 
DEFINITIONS FOR ILLUMINATED LED INDICATORS 
LED  Alarm  Condition 
On  Off  Normal 
Flash  Beep Twice  Utility Failure - The UPS is providing battery power to outlets. 
Flash  Rapid Beeping 
Utility Failure - The UPS is providing battery power.    The rapid beeps indicate the battery will run out of power 
shortly. 
On/Flash  Constant Tone 
Overload - Occurs when connected equipment exceeds the rating of the unit. Turn the UPS off and unplug at least 
one piece of equipment from the UPS.   
Specyfikacje produktu
| Marka: | CyberPower | 
| Kategoria: | UPS | 
| Model: | UT1050EI | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z CyberPower UT1050EI, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje UPS CyberPower
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         28 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025
                        
                    
                                                            
                        
                         27 Stycznia 2025
                        
                    
                                                            
                        
                         15 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         3 Stycznia 2025
                        
                    
                                                            
                        
                         30 Grudnia 2025
                        
                    
                                                            Instrukcje UPS
- FSP
- Maruson
- GYS
- Voltcraft
- Tripp Lite
- Minute Man
- Eaton
- Atlantis Land
- Siemens
- Online USV
- Bxterra
- Emerson
- Gembird
- Block
- Riello
Najnowsze instrukcje dla UPS
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         2 Kwietnia 2025
                        
                    
                                                            
                        
                         30 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         29 Marca 2025
                        
                    
                                                            
                        
                         27 Marca 2025