Split type wall mounted air-conditioner
WWW.DAIZUKI.COM
OWNER'S MANUAL
Please read this owner's manual carefully and thoroughly before operating the unit!
Take care of this manual for future reference.
CONTENTS
Safety Precautions
Name Of Each Part
WEEE Warning
1
5
6
7
8
8
10
11
12
13
14
16
17
17
4
Test running
Packing list
Operation
Notices
Care and Maintenance
Troubleshooting
Installation Guide
Selection of the installing position
Installation of the indoor unit
Installation of the outdoor unit
Pipe connection
Electrical connection
Make sure that pipes and wires are connected.
Make sure that liquid side valve and air side valve
both are completely open.
1. The connection of power source
Connect the wire to independent power source socket.
Preparation of remote controller.
Run the air-conditioner in cooling operation mode
for 30 minutes or longer.
2. Performance evaluation
Test the out and in air temperature.
Make sure whether the outlet air temperature subtract from inlet's gives more
than 10°C
Test running
Discharged air
Packing list
Please check the following attach carefully, if part attach isn t useful, please take
care of it.
Packing list of the indoor unit
Packing list of the outdoor unit
NO.
Name Unit
Quantity
1
2
3
4
5
Indoor unit
Remote controller
Instructions
Batteries
Drain pipe
Set
PC
PC
PC
PC
1
1
1
2
1
NO.
Name Unit
Quantity
1
2
3
4
5
Outdoor unit
Connection pipe
Plastic strap
Pipe protection ring
Luting (putty)
Set
PC
ROLL
PC
PACKET
1
2
1
1
1
- 17 -
Note:
Explanation for the power cord without
plug (see below figure):
Brown= Live wire
Blue= Zero line
Yellow/Green= Grounded wire
Wiring diagram of constant speed
Unscrew the screw, take off the control panel cover from the unit.
Connect the cable to their terminals according to their number.
The grounded wire connection:
1.loosen the grounded screw of electrical shelf.
2.Connect the grounded wire with the grounded screw
then setscrew in the "
"mark formerly.
Fix the cable to the terminal board with
fastening piece.
Reinstall the cover with the screw.
NOTE:
Don't reverse the power polarity.
The wrong connection lead to the mal
function of some electrical parts.
Must fix the screwnail of the firmly wire,
then drag the wire lightly, confirmation
whether it's firmly.
Must changed if the wire slide, the self-
drive
screw
can't used to the electric connection.
If there is a connector, connect it directly.
Heat pump Type
Cold wind Type
Connection plug
Connection plug
Connection plug
Outdoor unit terminal block
L N S V F
Yellow/green
To power
To indoor unit
Yellow/green
Brown
Blue
L N
S V
F
L N S V F
Yellow/green
To power
To indoor unit
Yellow/green
Brown
Blue
L N
S
To power
The connection of 24000Btu
30000Btu and 36000Btu.
V F C N
To indoor unit
To power
The connection
of 18000Btu.
Cover
More than 5mm
To indoor Unit
To power
1
2(N)
L N
Yellow
green
Heat pump Type
L N N1 CL1
Yellow/green
To power
To indoor unit
Yellow/green
Brown
Blue Red
L N 2 31
Yellow/green
To power
To indoor unit
Red
2 31
Yellow/green
Brown
Electrical connection
Wiring diagram of variable speed
Connection plug
NOTE:
This manual is usually includes the wiring mode for the different kind A/C. We cannot
exclude the possibility that some special type of wiring diagrams are not included .
please refer to the detailed wiring diagram which is adhered on the back of the panel
of indoor unit and E-parts cover of outdoor unit when wiring.
Note:
earthing wire should be
connected to electronic
part box (sheet metal).
Reference to photo.
Grounded wire
Earthing point
WARNING
Safety Precautions
Incorrect operation due to ignoring instruction will cause
harm or damage. The seriousness is classified by the
following indications:
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to
properties only.
1.This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.(Only for the AC with CE-MARKING)
2.This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance.
(Except for the AC with CE-MARKING)
3.The air conditioner must be grounded. Incomplete grounding
may result in electric shocks. Do not connect the earth wire
to the gas pipeline, water pipeline, lightning rod, or telephone
earth wire.
4.Don't pull out the power plug during operating or with wet
hands.
It can cause electric shock or fire.
5.The appliance shall be installed in accordance with
national wiring regulations.
To indoor unit
L1
L2
S
To power
L1
S
L2
- 1 -- 16 -