INSTALLATION
RCI 171HD
MAGNETIC LOCK FOR HAZARDOUS LOCATIONS
© 2018 dormakaba Canada Inc
www.dormakaba.us • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales_RCI@dormakaba.comIS171HD
PCN18041
R10-18GR
See Figure 1 elevation profiles to determine mounting application
requirements for each individual application.
Note: A 2-1/2” (64mm) reveal is required to assure rigid mounting of
the RCI 171HD magnetic lock assembly.
1. Mark door according to armature template and dimensions on
reverse side.
2. Drill and prep holes in door per armature template on reverse
side.
3. Gently tap (2) 3/16” (5mm) diameter spring pins into rear side of
armature(s).
4. Insert one (1) spring washer over 5/16”-18 special shoulder
screw, insert the screw through the armature.
Add three(3) conical spring washers and one (1) flat washer over
the shoulder screw.
Carefully apply thread locking compound to exposed thread.
See Figure 2 details for each type of installation.
All parts must be assembled properly before installing the
armature to the door.
Install complete armature assembly on the door per Figure 2
detail.
5. Tighten shoulder screw securely with allen wrench.
(Do not overtighten.)
Note: All armatures are normally equipped with a permanent magnet on
one end. Be certain to install armature so magnet lines up with magnet
switch inside housing of magnetic lock assembly. See Figure 3.
6. Mark frame per magnetic lock template and dimensions on
reverse side.
7. Remove housing cover of Magnetic Lock Assembly.
8. Drill and prep frame per “D” of Magnetic Lock template.
Attach Magnetic Lock Assembly to the frame using either (2) #14
sheet metal screws or (2) 1/4”-20 machine screws and external
tooth lock washers.
Tighten only enough to hold the unit in place.
(If filler plate is used, assure thet the screws go through both the
filler plate and the door frame.)
9. Drill 7/8” (22mm) diameter hole through filler plate and frame
per template for wire harness.
10. Make all electrical connections per Electrical Specifications box
on page 2. Use wire nuts, crimp connectors or solder to assure
good connections.
11. Energize Magnetic Lock Assembly; Adjust assembly so door is
snug against door stop, tighten (2) preliminary screws securely.
12. De-energize system.
Using mounting plate as a template, drill #21 drill and tap for
10-32 screws (minimum (2) places).
Carefully apply thread locking compound to exposed threads.
See Magnetic Lock template.
Install screws and tighten securley.
Re-energize system, recheck alignment of Magnetic Lock
Assembly to Armature by opening and closing door(s).
13. Install Magnetic Lock housing cover.
Pre-Installation Instructions
IMPORTANT! Read thoroughly before attempting installation.
Do not damage or mark magnetic lock or armature face - may
reduce holding efficiency.
This product is intended to be used in Class I Division 2 hazardous
locations. The following guidelines must be observed to reduce the
risk of fire explosion.
All national and local codes must be followed in the installation of the
magnetic lock assembly. For code interpretation, consult a local code
authority
This unit must be connected to an NEC (National Electric code, NFPA
70) Class 2 Supply. Operating temperature for the magnetic lock will
not exceed 185 F (85° C). Maximum ambient temperture is not to °
exceed 104° F (40° C).
For supply connections, use a suitable wire with a mimimum insulation
temperature rating of 167° F (75° C)
To reduce the risk of the ignition of hazardous atmosphere, disconnect
the magnetic lock assembly from the supply circuit before opening
the magnetic lock housing. Keep the unit properly sealed while in
operation. To reduce the risk of fire or explosion, do not install the unit
where the operating temperature exceeds the ignition temperature of
the hazardous atmosphere.
This unit is intended to be used in the following atmospheres;
Acetone, Ammonium Hydroxide, ATSM fuel C, Benzene, Methyl-
Ethylketone, Diethyl-Ether, 2-Nitropropane, Ethyl-Acetate, Furfural,
Normal Hexane, Methyl Alcohol
The product should be installed in a location that will not hinder or
create a potential safety hazard to authorized personnel accessing the
protected area.
Because electromagnetic locks are used in a variety of applications
and different door frame configurations, an experienced installer with
knowledge of this product must make a determination of the optimal
mounting method for this specific application.
Do not install this product on the exterior of buildings.
Do not use as a doorstop. This will void warranty.
NOTE: It is highly recommended that thread locking compound
be applied to all screws during installation to reduce chance of
screws loosening over extended time.
PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO
THE END-USER UPON COMPLETION OF THE INSTALLATION.
Use with Underwriters Laboritories Listed (ULC/UL) compatible power supply


Specyfikacje produktu

Marka: Dormakaba
Kategoria: nieskategoryzowany
Model: RCI 171HD

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Dormakaba RCI 171HD, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Dormakaba

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Asko

Asko DBI644MIB.S.TW/1 Instrukcja

28 Października 2024
Asko

Asko DFS233IB.S.TW/1 Instrukcja

28 Października 2024
Emko

Emko EZM-9920 Instrukcja

27 Października 2024
Emko

Emko ESM-3712-H Instrukcja

27 Października 2024
Emko

Emko ATS-10 Instrukcja

27 Października 2024
Emko

Emko EAOM-11.2 Instrukcja

27 Października 2024
Emko

Emko EPM-3790 Instrukcja

27 Października 2024
Emko

Emko EPM-7790 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux IAN 108340 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux HG06009A-BS Instrukcja

27 Października 2024