Instrukcja obsługi Eastron SDM230M
Eastron Sprzęt pomiarowy SDM230M
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Eastron SDM230M (2 stron) w kategorii Sprzęt pomiarowy. Ta instrukcja była pomocna dla 30 osób i została oceniona przez 7 użytkowników na średnio 4.3 gwiazdek
Strona 1/2

1.Introduction
1.1 Key Characteristics
1.2 Pulse output
1.3 RS485 Serial – Modbus RTU
1.4 Mbus for SDM230-Mbus
User Manual V1.6
SDM230 Series
Single Phase Two Wire Multifunction Din Rail Meter
.
The bi-directional measurement makes the meter
suitable for active and reactive energy and power
monitoring applications, and also perfect for solar PV
measurements. With RS485 Modbus and M-bus port,
the meter is easy to remote communication with other
AMR/SCADA systems.
·Bi-directional measure and display
·Multi-function measurements
·Two Pulse outputs
·RS485 Modbus / M-bus
·100A direct connection
·Two module size (35mm)
·Password protected set-up
·Backlighted LCD
·2 tariff dual power source
The meter provides two pulse outputs. Both pulse outputs
are passive type.
Pulse output 1 can be set to generate pulses to represent
total / import/export kWh or kVArh.
The pulse constant can be set to generate 1 pulse per:
0.001/0.01/0.1/1kWh/kVArh (default is 0.001 export kWh).
Pulse width: 200/100/60ms
Pulse output 2 is non-configurable. It is fixed up with active
kWh (Imp). The constant is 1000imp/kWh.
RS485 serial port with Modbus RTU protocol to provide
a means of remotely monitoring and controlling the
Unit.Set-up screens are provided for setting up the
RS485 port.
This unit has an M-BUS serial port with M-BUS protocol
to provide a means of remotely monitoring and controlling
the unit set-up screens are provided for setting up the
M-bus port.
1.5 2T by time relay for SDM230-2T
The unit has a time relay inside which can monitor if there
is external 230V signal input. If there is 230V signal input,
the meter switches Tariff 2 measurement, otherwise it will
measure as Tariff 1.
2.Operation
2.1 LCD Display
ModelMeasurementsPulse OutputsMulti
Tariffs
SDM230-
Modbus
U, I, P, Q, S, PF, Hz,
Dmd, kWh, kVArh,
Import, Export
RS485
Modbus
1:
configurable
2:
1000imp/kwh
NO
SDM230-
2T
1:
configurable
2:
1000imp/kwh
U, I, P, Q, S, PF, Hz,
Dmd, kWh, kVArh,
Import, Export
SDM230-
Mbus
U, I, P, Q, S, PF, Hz,
Dmd, kWh, kVArh,
Import, Export
M-bus
EN13757-3
1:
configurable
2:
1000imp/kwh
NO
Communi-
cation
1
1
1
11
2
2
2
22 3
3
3
33 4
4
4
44 5
5
5
55 6
6
6
66
7
7
7
77
8
8
8
88
9
9
9
99
1
1
1
110
0
0
00
11
11
11
1111
1
1
1
112
2
2
22
1
1
1
113
3
3
33
2 Tariffs
(time relay)
RS485
Modbus
10 Import(input)reactive energy
Example: 5.00kVArh
11Export(output)reactive energy
Example: 5.00kVArh
9
T2 reactive energy
Example: 2.00kVArh
(for SDM230-2T only)
The setting is done correctly
The entering information is
wrong. The operation fails.
12 Resettable total energy
Warnings
Important Safety Information is contained in the
Maintenance section. Familiarize yourself with this
information before attempting installation or other
proce d ures.
Risk of Danger: These instructions contain
important safety information. Read them before
starting installation or servicing of the equipment.
Caution: Risk of Electric Shock
!
!
!
!!
11
NO.
2
3
4
5
6
7
8
9
10
13
Descriptions
7 digits used to display measured values
Total value
Import information, Export information
Max. Demand for Power or Current.
Pulse output 1and Pulse output2
Measurement units
PF = power factor Hz = frequency
Bar display of Power
Communication indicatior
Lock symbol
Tariff information
2.3 Scroll display by Buttons
After initialization and self-checking program, the meter
display the measured values. The default page is total
kWh. If the user wants to check other information, he
needs to press the scroll button on the front panel.
The display order by scroll button :
Total kWh→ Import kWh→Export kWh→ Resettable kWh→
Total kVArh→Import kVArh→ Export kVArh→Resettable kVArh
→ Max. Power Demand→ Voltage →Current→W→ Var →
VA→ Power Factor→Frequency →Pulse Constant→ Modbus ID
→ Baud Rate →Continuous Running Time
Display No:1,4~7,10~24.
*For SDM230-Modbus:
*For SDM230-2T:
Total kWh→ T1 total kWh→ T2 total kWh→Import kWh→
Export kWh →resettable kWh→Total kVArh→T1 total kVArh
→T2 total kVArh→Import kVArh→ Export kVArh→ resettable kVArh
→Max. Power Demand→ Voltage →Current→W→ Var →VA
→ Power Factor → Frequency → Pulse Constant → Modbus ID →
Baud Rate → Continuous Running Time
Display No: 1~24.
7Total reactive energy
Example: 10.00kVArh
Software version (please check
the real software version on the
product as the final).
Modbus ID or Mbus Primary Address
2.2 Initialization Display
All display segments light up,
display check.
*For SDM230-Mbus:
Total kWh→ Import kWh→Export kWh→ Resettable kWh→
Total kVArh→Import kVArh→ Export kVArh→ Resettable kVArh
→ Max. Power Demand→ Voltage →Current→W→ Var →VA
→ Power Factor → Frequency →Pulse Constant→
Mbus Primary Address→Mbus Secondary Address→
Baud Rate→Continuous Running Time
Display No:1,4~7,10~24.
2
T1 active energy
Example: 10.00kWh
(for SDM230-2T only)
3
T2 active energy
Example: 10.00kWh
(for SDM230-2T only)
1Total active energy
Example:70.00kWh
4Import(input) active energy
Example: 50.00kWh
5Export(output) active energy
Example: 20.00kWh
8
T1 reactive energy
Example: 2.00kVArh
(for SDM230-2T only)
6Resettable total energy
2.4 Set-up Mode
To get into Set-up Mode, the user needs to press the “Enter”
button for 3 seconds.
17 Reactive power
Example: 1030Var
18 Apparent power
Example: 4811VA
19 Power factor
Example: 1.000
20 Frequency
Example: 49.99Hz
21 Pulse 2 constant
Example: 1000
22
Modbus address
Example: 001
Mbus primary address
Example:001
22-1
High and Low bit of MBUS
Secondary address
(Default 00 00 00 01)
Example: if the Secondary
address high bit is 0000,
low bit is 0001,that means
the integral Secondary
address is 00 00 00 01
(for SDM230-Mbus only)
23 Baud rate
Example: 9600
Continuous running time
(since last time reset)
24
This document provides operating, maintenance and
installation instructions of SDM230 series made by
Eastron Electronic Co., Ltd. The SDM230 series
measure and display the characteristics of single phase
two wire (1p2w) network. The SDM230 series covers 5
m o de l s : S DM 2 3 0 - M od b u s , SD M 2 3 0 -P u l s e , SD M 2 3 0 -
Mbus, SDM230-2T and SDM230-Std.
SDM230-
Pulse
U, I, P, Q, S, PF, Hz,
Dmd, kWh, kVArh,
Import, Export
NO
1:
configurable
2:
1000imp/kwh
NO
SDM230-
Std
1:
configurable
2:
1000imp/kwh
kWh, kVArh,
Import, Export
RS485
Modbus NO
Baud rate.
Total kWh.
Mbus Secondary Address (Low)
(for SDM230-Mbus only)
Mbus Secondary Address (High)
(for SDM230-Mbus only)
Total kWh→ Import kWh→Export kWh→ Resettable kWh→
total kVArh→Import kVArh→ Export kVArh→resettable kVArh
→ Max. Power Demand→ Voltage →Current→W→ Var →
VA→ Power Factor→Frequency →Pulse Constant
Display No:1,4~7,10~21.
*For SDM230-Pulse:
*For SDM230-Std:
Total kWh→ Import kWh→Export kWh→ Resettable kWh→
Total kVArh→Import kVArh→ Export kVArh→ Resettable kVArh
→ Pulse Constant→ Modbus ID→ Baud Rate →
Continuous Running Time
Display No:1,4~7,10~12, 21~24.
16 Active power
Example: 4700W
Current
Example: 30.156A
15
Voltage
Example: 229.8V
14
13 Max. power demand
Example: 6938W
Specyfikacje produktu
| Marka: | Eastron |
| Kategoria: | Sprzęt pomiarowy |
| Model: | SDM230M |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Eastron SDM230M, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Sprzęt pomiarowy Eastron
31 Grudnia 2025
16 Września 2024
15 Września 2024
13 Września 2024
1 Września 2024
27 Sierpnia 2024
26 Sierpnia 2024
24 Sierpnia 2024
22 Sierpnia 2024
20 Sierpnia 2024
Instrukcje Sprzęt pomiarowy
Najnowsze instrukcje dla Sprzęt pomiarowy
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025