Instrukcja obsługi ENTES MPR-14S-M3609
ENTES
Sprzęt pomiarowy
MPR-14S-M3609
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla ENTES MPR-14S-M3609 (20 stron) w kategorii Sprzęt pomiarowy. Ta instrukcja była pomocna dla 17 osób i została oceniona przez 9 użytkowników na średnio 4.9 gwiazdek
Strona 1/20

1
Index
SAFETY AND WARNING ................................................................................................................................ 2
Attention .................................................................................................................................................. 2
Safety ....................................................................................................................................................... 3
Guarantee ................................................................................................................................................ 3
OPERATING CONDITIONS ............................................................................................................................. 4
INTRODUCTION ............................................................................................................................................ 5
General Specifications ................................................................................................................................. 5
Applications 6 ..............................................................................................................................................
MPR-1 Product Family 6 .............................................................................................................................
Appearance and Interface 7 .......................................................................................................................
Terminals ...................................................................................................................................................... 7
Front Panel ................................................................................................................................................... 7
Terminal Structures 8 ..................................................................................................................................
CONNECTION ............................................................................................................................................. 12
3P4W (Three-Phase Four-Wire) Connection .........................................................................................12
3P3W (Three-Phase Three-Wire) Connection .......................................................................................13
ARON Connection .................................................................................................................................. 13
3P4W BLN (Three-Phase Four-Wire Balanced) Connection ..................................................................14
3P3W BLN (Three-Phase Three-Wire Balanced) Connection . ................................................................ 14
Communication Line Termination Resistance ....................................................................................... 15
OPERATING DEVICE .................................................................................................................................... 16
Device Communication Settings………………………………………………………………………………………………..…… …... 16
TECHNICAL INFORMATION AND ATTACHMENTS………………………………………………………………………………….17
Technical Information…………………………………………………………………………………………………………………………..17
Standards………………………………………………………………………………………………………… ………………………………….. 19
MPR-1 SERIES NETWORK ANALYZER
OPERATING MANUAL

2
SAFETY AND WARNING
Attention
If the following instructions are not carefully followed, the circumstances which can
cause death and serious injuries might happen.
The installation of the device must be performed by the qualied and trained
personnel.
Please, cut the whole power while installing the device. Please, use a suitable
circuit breaker on the installation terminal.
You must connect the power lead-ins of the device by using a current
transformer. Do not apply direct current connection.
Never, remove the front panel while the device is connected to the mains.
Never, clean the device by any solvent or similar material. Only use dry cloth for
cleaning it.
Before, turning on the device, make sure that the connections are correct.
Please, contact your authorized dealer in case of any problem with your device.
The device is only for interior panel type assembly. electrical / re enclosure
Only the front panel of the device should be accessible from the switchboard.
The fuse to be used must be CATIII and F type and the current limit value
should be 1A.
Current measurement inputs must be connected with auxiliary current
transformers which have reinforced insulation.
The power meter shall not be used for primary protection or applications where
its failure can cause harm or death.
Please de-energize the device before replacing RTC backup battery. It must be
Li/MnO2 battery.
The manufacturer rm cannot be held responsible in any way for any circumstance
which might arise if the aforementioned precautions are not implemented
.

3
Safety
Please, read the entire operating manual before using the device.
Connect a button or a circuit breaker between the mains and the supply inputs
of the device.
The button or circuit breaker to be connected should be close to the device.
It should be labeled that the button or circuit breaker to be connected will be
used for separating the device from the mains.
This device is used for analyzing the electricity mains and it must not be used for
main protection function.
Guarantee
The guarantee term of the device is 2 (two) years. In case of any problem, the repair of
the device must be done only by the manufacturer rm; otherwise, the guarantee of the
device becomes invalid.
Manufacturer Firm
ENTES Elektronik Cihazlar Imalat ve Ticaret A.S.
Address: Dudullu OSB, 1. cadde, No:23 34776 Umraniye, Istanbul / TR.
Telephone: +90 (216) 313 0110
Fax: +90 (216) 314 1615
Specyfikacje produktu
Marka: | ENTES |
Kategoria: | Sprzęt pomiarowy |
Model: | MPR-14S-M3609 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z ENTES MPR-14S-M3609, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Sprzęt pomiarowy ENTES
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
29 Września 2024
26 Września 2024
26 Września 2024
26 Września 2024
26 Września 2024
Instrukcje Sprzęt pomiarowy
- Sprzęt pomiarowy Holzmann
- Sprzęt pomiarowy Sanwa
- Sprzęt pomiarowy Klein Tools
- Sprzęt pomiarowy Multimetrix
- Sprzęt pomiarowy GW Instek
- Sprzęt pomiarowy Megasat
- Sprzęt pomiarowy PQ Plus
- Sprzęt pomiarowy Hanna
- Sprzęt pomiarowy Hager
- Sprzęt pomiarowy Stamos
- Sprzęt pomiarowy Fixpoint
- Sprzęt pomiarowy Black & Decker
- Sprzęt pomiarowy Testo
- Sprzęt pomiarowy Hikmicro
- Sprzęt pomiarowy Atmel
Najnowsze instrukcje dla Sprzęt pomiarowy
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025