Instrukcja obsługi ETI Thermapen Mk4
ETI
termometr do żywności
Thermapen Mk4
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla ETI Thermapen Mk4 (4 stron) w kategorii termometr do żywności. Ta instrukcja była pomocna dla 9 osób i została oceniona przez 5 użytkowników na średnio 4.3 gwiazdek
Strona 1/4

Congratulations
The new Super-Fast Thermapen Mk4 is a precision thermometer used for many applications,
including cooking. With proper care, it will offer accurate measurements for many years. The
new Mk4 Thermapen includes several new features, including: intelligent backlight, auto-
rotating display, user-selectable sleep interval, motion-activated wake-up mode, and added
water resistance.
Instrument Operation
The unit is switched on by unfolding the thermocouple probe
until the display comes on. Conversely, the unit is turned
off by folding the probe away and lightly pressing the tip
into the rubber probe retainer located at the bottom rear of
the instrument. It is recommended to store the probe in the
closed position when not in use.
Do not force the probe further than 180° when opening
or damage to the rotating hub may occur.
The micro-thermocouple sensor is located at the tip of the probe shaft. Minimum immersion
is only 1/8" (3 mm). For best results, immerse or penetrate the probe into the food item so the
probe tip is in the place you want to measure. In food, this should normally be at the center
of the thickest part.
The Thermapen will read to within 1°F of the actual
temperature of an ice bath within three seconds. Reading
times in other foods may vary slightly.
Do not immerse the probe all the way to the plastic
rotating hub. Avoid getting flour, moisture, or oil on the
hub itself. Although there is an O-ring seal, oils can
work their way past the seal and accumulate inside
the hub and may cause failure. The probe tip is sharp.
Use caution to avoid injury. Do not “stab” the material
to be measured. Use steady force to penetrate meats
or semi-solids. Avoid bone. Do not lift or flip heavy
meats with the probe tip. The probe shaft is hollow and
contains a sensor. If bent, it may fail.
Rotating hub
0.1”
0.55”
0.65”
0.125 dia”
Probe Tip
Sensor location
Minimum immersion 1/8"
Thermapen
®
Mk4
Operating Instructions
1
2
3
4
5
6
7
8
165°F
140°F
Specyfikacje produktu
| Marka: | ETI |
| Kategoria: | termometr do żywności |
| Model: | Thermapen Mk4 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z ETI Thermapen Mk4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termometr do żywności ETI
2 Października 2024
Instrukcje termometr do żywności
- Emos
- Tepro
- Etekcity
- Electrolux
- Technoline
- MEATER
- Extech
- Maverick
- Testo
- FCC BBQ
- Tenneker
- Grill Eye
- Mastrad
- AcuRite
- TFA Dostmann
Najnowsze instrukcje dla termometr do żywności
28 Grudnia 2024
26 Grudnia 2024
7 Grudnia 2024
7 Grudnia 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
9 Października 2024
7 Października 2024