Congratulations
The new Super-Fast Thermapen Mk4 is a precision thermometer used for many applications,
including cooking. With proper care, it will offer accurate measurements for many years. The
new Mk4 Thermapen includes several new features, including: intelligent backlight, auto-
rotating display, user-selectable sleep interval, motion-activated wake-up mode, and added
water resistance.
Instrument Operation
The unit is switched on by unfolding the thermocouple probe
until the display comes on. Conversely, the unit is turned
off by folding the probe away and lightly pressing the tip
into the rubber probe retainer located at the bottom rear of
the instrument. It is recommended to store the probe in the
closed position when not in use.
Do not force the probe further than 180° when opening
or damage to the rotating hub may occur.
The micro-thermocouple sensor is located at the tip of the probe shaft. Minimum immersion
is only 1/8" (3 mm). For best results, immerse or penetrate the probe into the food item so the
probe tip is in the place you want to measure. In food, this should normally be at the center
of the thickest part.
The Thermapen will read to within 1°F of the actual
temperature of an ice bath within three seconds. Reading
times in other foods may vary slightly.
Do not immerse the probe all the way to the plastic
rotating hub. Avoid getting flour, moisture, or oil on the
hub itself. Although there is an O-ring seal, oils can
work their way past the seal and accumulate inside
the hub and may cause failure. The probe tip is sharp.
Use caution to avoid injury. Do not “stab” the material
to be measured. Use steady force to penetrate meats
or semi-solids. Avoid bone. Do not lift or flip heavy
meats with the probe tip. The probe shaft is hollow and
contains a sensor. If bent, it may fail.
Rotating hub
0.1”
0.55”
0.65”
0.125 dia”
Probe Tip
Sensor location
Minimum immersion 1/8"
Thermapen
®
Mk4
Operating Instructions
1
2
3
4
5
6
7
8
165°F
140°F


Specyfikacje produktu

Marka: ETI
Kategoria: termometr do żywności
Model: Thermapen Mk4

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z ETI Thermapen Mk4, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje termometr do żywności ETI

ETI

ETI Thermapen Mk4 Instrukcja

2 Października 2024

Instrukcje termometr do żywności

Najnowsze instrukcje dla termometr do żywności

TFA

TFA 14.1510 Instrukcja

7 Grudnia 2024
Hendi

Hendi 271315 Instrukcja

9 Października 2024
Taylor

Taylor 9840 Instrukcja

9 Października 2024
Taylor

Taylor 1471N Instrukcja

9 Października 2024
Taylor

Taylor 5309295 Instrukcja

9 Października 2024
Taylor

Taylor 5265467 Instrukcja

9 Października 2024