INSTALLATION
P30A GENERAL CONTROL PANEL INSTALLATION
Screw the xing stay-bar and release the control panel
socket . Remove the socket by pulling with a
screwdriver on the latching tabs.
Fix the terminal-holders of the wall detector (according
to the xing systems shown hereby) in a dry not
dripping place.
SENSORS DETECTORS
They shuold be xed on a wall at an approximate
distance of 2 meters form the gas device in such a
position as to allow natural air circulation:
-S71 for specic ligth gases (natural gas, city gas) has
to be xed at an high level approximately 30/40 cm
from the ceiling.
-S72 for heavy gases (cylinder liquid gas LGP) has to
be xed to a low level approximately 30/40 cm above
the oor.
Avoid installing sensors:
-behind barriers that can prevent the natural air
circulation in the area
-close to air conditiong units (minimum distance 2
meters)
-close to fumes, steams or other exhalation sources
Remove the cover four front retaining screws, x the
base to the wall, using for the cables entrance the
special press-.cables.
GAS DETECTOR VALVE
Choose the gas interception valve among one of the
serie Z-EV, generally closed with quick on and o
realease switch, class A with approval (or
corresponding models) according to diameter and gas
pipe type.
Install the valve in the most suitable part of the plant
downstream the counter or at the exit of the
accumulation tanks.
ACOUSTIC/VISUAL EXTERNAL SIGNALLER
Use the self-fed type most suitable with your kind of
plant, place it in an easely visibles place.
CONNECTIONS WITH POSSIBLE FIRE ALARM
CONTROL SYSTEM AND/OR ANTI-INTRUSION
DEVICE.
The voltage free terminal exchange contact available
for the external acoustic/visual signaller can in
alternative be used for connections with alredy exiting
central alarm panels.
CONTROL PANEL
CENTRAL CONTROL CONSOLE
Visual indicator: normally switched off, flashes in case
of alarm. It can be switched off only through the reset
button.
Operating indicator: always switched on.
Alarm sensors indicators: generally switched off they
switch on when the connected sensor send an alarm
signal. They switch off when the gas concentration
goes back to the allowed levels.
Test switcher to verify the device except for the
sensors.
Switch for external siren silencing: it allows to switch
off the siren even during an alarm situation.
Reset switch to stop the alarm after the cause has
been removed.
Operation delay: unique for all sensors, regulates the
delay once that a warning situation has been detected
by all sensors and it has activated the general alarm.
Acoustic signaller: positioned inside the central
control panel operates in case of alarm. It can be
switched off only through the reset switch.
SENSOR
Operating indicator: always switched on.
Fault indicator sensor
Alarm indicator: generally switched off, it operates
and remains on for all the time in which the gas
concentration remains above the established level.
A
B
C
D
E
F
G
H
I
L
M
C
B
I
L
M
F
H
GA
SENSORS
CENTRAL
(INTERNALS)
93
91
110
P30A CENTRAL CONTROL PANEL:
OVERALL DIMENSIONS
WALL FIXING
BACK-CONTROL CONSOLE FIXING
EXTRACTION SOCKET
SENSORS: OVERALL DIMENSIONS
Specyfikacje produktu
| Marka: | Fantini Cosmi |
| Kategoria: | detektor gazu |
| Model: | P30A |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Fantini Cosmi P30A, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje detektor gazu Fantini Cosmi
1 Kwietnia 2025
27 Marca 2025
13 Września 2024
21 Sierpnia 2024
19 Sierpnia 2024
19 Sierpnia 2024
18 Sierpnia 2024
18 Sierpnia 2024
7 Sierpnia 2024
6 Lipca 2024
Instrukcje detektor gazu
Najnowsze instrukcje dla detektor gazu
10 Stycznia 2025
8 Stycznia 2025
28 Grudnia 2024
27 Grudnia 2024
20 Grudnia 2024
15 Grudnia 2024
12 Grudnia 2024
9 Października 2024
9 Października 2024
7 Października 2024