Instrukcja obsługi FireAngel W2-Module
                    FireAngel
                    
                    Detektor dymu
                    
                    W2-Module
                
                                
    Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla FireAngel W2-Module (2 stron) w kategorii Detektor dymu. Ta instrukcja była pomocna dla 30 osób i została oceniona przez 15.5 użytkowników na średnio 4.9 gwiazdek
                        Strona 1/2
                    
                    
                    
The  original  English  version  of  the  manual,  from  which  these 
translations  were  taken,  has  been  independently  approved.  In  case 
of  discrepancy  with  translated  parts,  FireAngel  Safety  Technology 
Limited  conrms  that  the  English  guide  is  true  and  correct. 
INTRODUCTION
This  wireless  module  is  designed  to  be  installed  in  a  Wi-Safe  2  
compatible  smoke/heat  alarm  or  Wi-Safe  2  compatible  Carbon  
Monoxide  alarm  which  offers  an  additional  option  for  wireless  
connectivity (and which is not already wireless enabled). For the current 
range of Wi-Safe 2 compatible products see www.reangeltech.com
When  the  wireless  module  is  tted  into  a  Wi-Safe  2  compatible 
FireAngel  Safety  Technology  Limited  smoke/heat  alarm  or  carbon 
monoxide  alarm  it  enables  the  unit  to  be  wirelessly  interlinked  with 
other Wi-Safe 2 enabled products.
When  any  of  the  interlinked  products  are  triggered  by  smoke/heat 
(or carbon monoxide in the case of CO alarms), that unit will transmit 
messages to the other  units in  the network,  sounding all  the alarms 
in the  system simultaneously, which means  they provide the  earliest 
warning of re, to the maximum number of people. Any number of units 
from two, up to fty alarms can be interlinked into a single network.
NOTE: You will need the User Manual of the product into which you are 
installing the wireless module in order to then wirelessly interconnect 
the  product with  other  alarms  in the  network.  If  this  is not  available 
please contact Technical Support on 0330 094 5830 or download from 
www.reangeltech.com
Please read these tting instructions carefully before proceeding, 
paying particular attention to the ESD handling guidelines below.
HOW TO INSTALL A WI-SAFE 2 
WIRELESS MODULE (W2-MODULE)
When you’re ready to install the wireless module into the compatible 
alarm, ensure you observe ESD handling guidelines.
•  Remove the label which covers the module aperture at the back 
of the unit.
•  Avoid  carpeted  areas  in  cool,  dry  areas  if  possible,  and  reduce 
static electricity if necessary by touching a grounded metal object.
•  Carefully  remove  the  module  from  its  packaging,  handling 
the  module  only  by  the  protective  plastic  cover,  to  avoid 
electrostatic discharge.
•  Be careful not to touch the components or connector pins.
•  Carefully plug the module into the aperture in the unit as shown, 
pushing down until it lies at within the base of the unit.
The  unit  is now  ready  to  be  “learned  –  in” (interlinked)  to  additional 
Wi-Safe 2 products.
“LEARNING IN” (INTERLINKING) 
YOUR WI-SAFE 2 UNITS
The process below describes ‘learning in’ two Wi-Safe 2 alarms into a 
network, “Alarm 1” and “Alarm 2”. Alarm 2 will be the unit into which 
you have installed the Wireless Module.
It is recommended that you read through these instructions prior 
to starting the process.
Alarm 1: Before starting, refer to the product’s User Manual to ensure 
the  alarm is  activated  and ready  to  be learned  in,  with its  mounting 
plate (if appropriate) attached. Please test the unit once after mounting 
to baseplate.
Alarm 2: Using a pen, a very small screwdriver or paper clip that has 
been opened out, briey push and release the learn button located in 
a small hole in the wireless module.   
The red LED next to the learn in button will ash briey then light up 
for approximately ve seconds to show that it is ready to receive the 
“learn  in”  signal.  During the  next  5  seconds  you  will  need  to  briey 
press the test button on Alarm 1 to wirelessly interlink the two alarms.
Alarm  1:  Will  give  an  audible  sound  consisting  of  2  cycles  of  3 
loud beeps.
Alarm  2:  The  red  LED  on  the  wireless  module  of  alarm  2  will  ash  to 
indicate that it has been “learned-in” successfully.
NOTE: If the test button is not pressed quickly enough (before the red 
LED on the wireless module of Alarm 2 has extinguished), the learn-in 
process will fail. If this happens, repeat the “learn-in” process again, 
as described above.
Additional  products  should  be  “learned-in”  in  the  same  way.  When 
learning in additional alarms, any alarm already in the network, can be 
used as ‘Alarm 1’.  This means that you can “learn-in”  the additional 
alarm into any unit already in the network. It will then become part of 
the whole network.
NOTE:  You  do  not need  to  “learn in”  the  additional alarm  into  each 
alarm in the network.
After completing the “learn-in” procedure, test the alarms as described 
in “alarm test” in the product’s user manual.
If  any  interlinked  alarm  fails  to  respond  to  the  “alarm  test”,  repeat 
the  learning  in  process.  If  the  product  continues  to  fail  to  operate 
correctly,  please  contact  Technical  Support  on  0330  094  5830  or 
email technicalsupport@reangeltech.com
For  information  about  where  to  position  the  alarm,  and  operational 
guidelines, please see the User Manual for the host product.
NOTE: The wireless range of the module is over 200 metres in clear air/
clear line of sight. Always ensure that after any building work or after 
repositioning large items of furniture (beds, sofas, shelving units etc.), 
you carry out an alarm test on all networked alarms to ensure they are 
all still communicating. It is recommended not to exceed 35m as the 
maximum distance between any interlinked Wi-Safe  2 alarm. Ideally, 
each unit should have three or more units within 35m of its location.  
TROUBLESHOOTING
Problem Solution (Alarm with W2 Module)
Your alarm does not 
sound during testing.
• Check positioning. The wireless signal might be blocked or out of range.
• If you are in the process of learning in the alarm and it does not test – repeat the process.
• If the alarm still fails to self test, please contact Technical Support (see below).
Your smoke alarm 
activates when no 
smoke is visible.
• If the alarm is sounding but the red LED is only ashing once every 45 seconds, this indicates 
that an interlinked alarm has initiated alarm. Vacate the property if there is a re hazard.
Your alarm chirps 
intermittently.
• If your alarm is chirping once every 4 hours, it is indicating that another alarm in the network has 
entered a low power pack condition. Locate the alarm with the low battery condition and replace 
the alarm as soon as possible and in any event within 30 days.
Other interlinked units 
fail to silence when one 
unit is silenced.
• Interlinked units that have sensed a hazard can’t be silenced. If one or more unit remains in 
alarm, all other interlinked units will emit their audible warning again within 4 minutes. Vacate the 
property if there is a re hazard.
You experience frequent 
unwanted alarms.
• Any activated alarm will cause other interlinked alarms to sound. Carry out these checks on the 
activated alarms in particular (red LED ashing rapidly during alarm).
The amber LED is 
ashing and the alarm 
is making a “chirping” 
sound.
• If the amber LED is double ashing and the alarm is making a “chirping” sound, this indicates 
that the wireless module has a low power pack condition, or is faulty. The W2 Module should be 
replaced as soon as possible.
If the alarm fails to 
operate correctly, 
the advice of the 
manufacturer should be 
sought.
• If you have any questions about the operation of your alarm, please contact Technical Support 
between 9am - 5pm Monday – Friday. Telephone: 
0330 094 5830
.
RF  range  can  be  reduced  by  walls,  and  other  obstructions  in  the 
building. The distance between units should be reduced if obstructions 
may interfere with RF range.
Unlearning your Wi-Safe 2 Unit:
To remove an alarm / module from a network, push and release, then 
push and hold the learn button. When the red LED goes out, release 
the button. Once the LED has ashed 5 times you have successfully 
‘Unlearned’ the alarm / module.
When removing  an alarm /  module from any Wi-Safe 2  network it is 
generally good practice to “unlearn” every alarm/module (in the same 
way  as  mentioned  before)  and  rebuild  the  network  once  again  by 
following the “learning-in” process.
NOTE:  It  is important  not  to  rush  the Wi-Safe  2  system  and  is also 
good  practice to  allow  several  minutes  after un-learning  the  system 
before rebuilding the network once again.
WARRANTY
FireAngel  Safety  Technology  Limited  warrants  to  the  original 
purchaser  that  its  enclosed  Wireless  Module  be  free  from  defects 
in  materials  and  workmanship  under  normal  residential  use  and 
service  for  a  period  of  5  (ve)  years  from  the  date  of  purchase. 
Provided  it  is  returned  with  postage  prepaid  and  proof  of  purchase 
date,  FireAngel  Safety  Technology  Limited  hereby  warrants  that 
during the 5 (ve) year period commencing from the date of purchase 
FireAngel  Safety  Technology  Limited,  at  its  discretion,  agrees  to 
replace  the  unit  free  of  charge.  The  warranty  on  any  replacement  
W2-Module,  will  last  for  the  remainder  of  the  period  of  the  original 
warranty in respect of the wireless module originally purchased – that 
is from the date of original purchase and not from the date of receipt of 
the replacement product.
FireAngel  Safety  Technology  Limited  reserves  the  right  to  offer 
an  alternative  product  similar  to  that  being  replaced  if  the  original 
model  is  no  longer  available  or  in  stock.  This  warranty  applies  to 
the  original  retail  purchaser  from  the  date  of  original retail  purchase 
and is  not  transferable. Proof  of purchase is  required.  This warranty 
does not cover damage resulting from accident, misuse, disassembly, 
abuse or  lack of reasonable  care  of the product,  or applications not 
in  accordance  with  the  user  manual.  It  does  not  cover  events  and 
conditions  outside  of  FireAngel Safety  Technology  Limited’s  control, 
such as Acts of God (re, severe weather etc). It does not apply to retail 
stores, service centres or any distributors or agents. 
FireAngel Safety Technology Limited will not recognise any changes to 
this warranty by third parties. FireAngel Safety Technology Limited shall 
not be liable for any incidental or consequential damages caused by 
the breach of any expressed or implied warranty. Except to the extent 
prohibited by applicable law, any implied warranty of merchantability 
or tness for a particular purpose is limited in duration for 5 (ve) years. 
This warranty does not affect your statutory rights. Except for death or 
personal injury, FireAngel Safety Technology Limited shall not be liable 
for any loss of use, damage, cost or expense relating to this product 
or for any indirect or consequential loss, damages or costs incurred by 
you or any other user of this product.
RETURNS
If your W2-Module fails to operate correctly and you cannot resolve the 
problem, please contact your dealer. 
Tel.: 0330 094 5830
E-Mail: technicalsupport@reangeltech.com
DISPOSAL
Waste  electrical  products  should  not  be  disposed  of  with 
your other household waste, but within the waste electronic 
and electrical equipment (WEEE) recycling scheme. Please 
recycle where facilities exist. Check with your local authority, 
or contact our technical support team for recycling /disposal advice as 
regional variations may apply.
WARNING: Do not attempt to open
WARNING: Do not burn or dispose of in re
TECHNICAL SPECIFICATION
Compliance:
EN 301 489-1
EN 301 489-3
EN 300 220-2
Max RF power: +10dBm
Frequency: 868MHz
Contains: 10 year lithium battery
Hereby,  FireAngel  Safety  Technology  Limited,  declares  that  this  
W2-Module  is  in  compliance  with  the  essential  requirements  and 
other relevant provisions of Directive 2014/53/EU. The declaration of 
conformity may be consulted at http://spru.es/EC-W2-Module
FURTHER INFORMATION
FireAngel Safety Technology Limited
Vanguard Centre, Coventry, CV4 7EZ
www.reangeltech.com
Red LED Amber LED Audible signal Status Action required
Flashes once every 45 
seconds
Single chirp every four 
hours
Other alarm in network 
has low battery
Locate alarm with low 
battery and replace
Flashes once every 45 
seconds
3 loud beeps repeating
Other alarm with W2 
Module in network in 
alarm
Check if there is a re 
hazard and vacate 
property
Flashes once every 45 
seconds
Double ashes at the 
same time as the red 
LED
Single chirp at the 
same time as the LED 
ash
Radio module low 
battery
Call Technical Support 
if within warranty. If not 
replace the W2 Module 
immediately
Flashes once every 45 
seconds
Double ashes every 
45 seconds, 20-25 
seconds after the red 
LED
Single chirp at same 
time as the red LED 
ash
Radio module fault
Call Technical Support 
if within warranty. If not 
replace the W2 Module 
immediately
ALARM INDICATORS
GN1830R8
W2-MODULE P-LINE INSTALLATION GUIDE - (EN)
EN  To  view  the  manual  online  in  your 
language, scan the QR code.
ً.ﺎﻴﺋﻮﺿ ﺔﻌﻳﺮﺴﻟﺍ ﺔﺑﺎﺠﺘﺳﻻﺍ ﺰﻣﺭ ﺢﺴﻣﺍ ،ﻚﺘﻐﻠﺑ ﺖﻧﺮﺘﻧﻹﺍ ﻰﻠﻋ ﻞﻴﻟﺪﻟﺍ ضﺮﻌﻟ AR
BG За  да  видите  ръководството  онлайн 
на Вашия език, сканирайте QR кода.
CZ 
Chcete-li zobrazit příručku online ve svém
jazyce, naskenujte QR kód.
DK Scan QR-koden for at se manualen online på dit sprog.
EE Selleks, et  näha juhendit veebis oma emakeeles skannige 
QR-kood.
ES Escanée el código QR para consultar el manual en línea en 
su idioma.
FI  Skannaamalla  QR-koodin  voit  näyttää  oppaan  verkossa 
omalla kielelläsi.
GR
 Για  να  δείτε  την  ηλεκτρονική  έκδοση  του  εγχειριδίου  στη 
γλώσσα σας, σκανάρετε τον κώδικα QR
HR
 Za  mrežni  prikaz  priručnika  na  vašem  jeziku, 
skenirajte kȏd QR.
HU
 Ha  szeretné  online  megtekinteni  az  útmutatót  a  saját 
nyelvén, olvassa be a QR-kódot.
IT   Per leggere il manuale online nella tua lingua, scansiona il 
codice QR.
LT  Norėdami  perskaityti  vadovą  internete  savo  kalba, 
nuskaitykite QR kodą.
LV Lai  tiešsaistē  skatītu  rokasgrāmatu  savā  valodā,  skenējiet 
kvadrātkodu.
NO Skann QR-koden for å se håndboken på nett på ditt språk.
PL Aby wyświetlić tę Instrukcję online w swoim języku zeskanuj 
kod QR.
PT Para ver o manual online no seu idioma, leia o código QR.
RO Pentru a vizualiza online manualul în limba dumneavoastră 
scanați codul QR.
RU
 Для  просмотра  руководства  на  своем  языке  в  сети 
Интернет отсканируйте QR-код.
SE Skanna QR-koden  för att  visa bruksanvisningen  online  på 
ditt språk.
SI  Skenirajte  QR-kodo,  da  si  na  spletu  ogledate  priročnih  v 
svojem jeziku.
SK Na zobrazenie online návodu vo svojom jazyku naskenujte 
kód QR.
UA Щоб  переглянути  інструкцію  в  режимі  онлайн  вашою 
мовою, відскануйте QR-код.
Specyfikacje produktu
| Marka: | FireAngel | 
| Kategoria: | Detektor dymu | 
| Model: | W2-Module | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z FireAngel W2-Module, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Detektor dymu FireAngel
                        
                         30 Grudnia 2025
                        
                    
                                                            
                        
                         30 Grudnia 2025
                        
                    
                                                            
                        
                         3 Października 2024
                        
                    
                                                            
                        
                         30 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            
                        
                         29 Września 2024
                        
                    
                                                            Instrukcje Detektor dymu
- X-Sense
- Abus
- First Alert
- Heatit
- Cavius
- Nest
- Alecto
- Fito
- ESYLUX
- Bosch
- Vivanco
- Marmitek
- Kidde
- Interlogix
- Flamingo
Najnowsze instrukcje dla Detektor dymu
                        
                         29 Stycznia 2025
                        
                    
                                                            
                        
                         14 Stycznia 2025
                        
                    
                                                            
                        
                         13 Stycznia 2025
                        
                    
                                                            
                        
                         13 Stycznia 2025
                        
                    
                                                            
                        
                         30 Grudnia 2025
                        
                    
                                                            
                        
                         29 Grudnia 2024
                        
                    
                                                            
                        
                         29 Grudnia 2024
                        
                    
                                                            
                        
                         27 Grudnia 2024
                        
                    
                                                            
                        
                         27 Grudnia 2024
                        
                    
                                                            
                        
                         27 Grudnia 2024