Instrukcja obsługi Grasslin telt 100


Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Grasslin telt 100 (18 stron) w kategorii Nie skategoryzowane. Ta instrukcja była pomocna dla 11 osób i została oceniona przez 6 użytkowników na średnio 4.6 gwiazdek

Strona 1/18
1 / 2
telt 100
40.02.0001.1
Made in the EU
2
3
1
4
5
6
N
L
L
N
16
18
N
L
L
N
16
18
Leopoldstr. 1
78112 St. Georgen / Germany
www.graesslin.de
Emergency light tester
Characteristics
Description
Connection
EN
Technical parameters
Time relay for automatic testing of emergency lighting.
Panel button for starting the test.
Comfortable and well-arranged time delay (t) setting by rotary switch.
Adjustable time delay 10 m – 30 m – 60 m – 90 m – 120 m – 180 m is divided into
six ranges.
ZERO CROSS feature: closes and opens the output contact when the voltage
crosses zero.
Multifunction red LED  ashes or shines depending on the operating states.
1. Supply voltage terminals (N-L)
2. Supply voltage indication
3. Indication of operating states
4. Time delay (t) setting
5. Test button
6. Output contact (16-18)
Direct emergency lighting
connection (for I<16A)
Emergency lighting connection
through contactor (for I>16A)
Power supply
Supply terminals:
Supply voltage:
Consumption (max.):
Supply voltage tolerance:
Time circuit
Number of functions:
Time delay (t):
Time setting:
Time deviation:
Repeat accuracy:
Temperature coe cient:
Output
Contact type:
Current rating:
Breaking capacity:
Inrush current:
Switching voltage:
Power dissipation (max.):
Mechanical life:
Electrical life (AC1):
Other information
Operating temperature:
Storage temperature:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Cross-wire section – solid/
stranded with ferrule (mm
2
):
Dimensions:
Weight:
Standards:
L-N
AC 230 V (50-60 Hz)
3.9 VA/1.9 W
15 %; +10 %
1
10 m – 30 m – 60 m – 90 m – 120 m – 180 m
rotary switch
5 % – mechanical setting
0.2 % – set value stability
0.01 %/°C, at = 20 °C (0.01%/°F, at = 68 °F)
changeover (AgSnO
2
); changes the potential "L"
16 A/AC1; 1 HP|240 Vac, 1/2HP|120 Vac; PD. B300
4000 VA/AC1, 384 W/DC1
80 A/20 ms (NO contact)
250 V AC/24 V DC
1.2 W
10.000.000 ops.
20.000 ops.
–20 .. +40 °C
–30 .. +70 °C
any
DIN rail EN 60715
IP40 front panel / IP20 terminals
III.
2
max. 1× 2.5, 2× 1.5/
max. 1× 2.5 (AWG 14)
90 × 17.6 × 64 mm
53 g
EN 61812-1


Specyfikacje produktu

Marka: Grasslin
Kategoria: Nie skategoryzowane
Model: telt 100

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Grasslin telt 100, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Nie skategoryzowane Grasslin

Instrukcje Nie skategoryzowane

Najnowsze instrukcje dla Nie skategoryzowane