1. The content of this document is continually reviewed and amended, where necessary. Growatt reserves the right to make changes to the
material at any time and without notice. Unless otherwise agreed, this document is for quick installation guidance only. All information and
suggestions in this document do not constitute a warranty of any kind, express or implied. Growatt reserves all rights for final explanation.
2. This document is for quick installation guidance only. For details, please refer to the User Manual.
3. Machine damage caused by failure to follow the instructions is not covered under any warranty.
1. The Load Breaker and the Pass Breaker should be interlocked.
2. When determining the installation position of the inverter, please consider the position of the batteries and the distribution panel.
2. For export limitation, you are advised to connect an energy meter and current transformers to the inverter.
water pipes and power cables
buried under the ground.
Battery BOX
Quick InstallationManual
1
Note:
2
2
2
22.
.
.
..
Installation
System overview
2.1 Installation requirements
2.2 Floor-mounted installation
2
3
Note:
Note:
Unit: inch
4 in
Φ.047 in
2.76 in
4 in
Unit: inch
WIT 28-55K-HU-US L2 Quick Guide
1
1
1
11.
.
.
..
Overview
(13) Battery terminal(14) BMS power supply port
(15) GRID terminal
(16) LOAD terminal
(1) Front panel
(2) OLED display screen
(3) Battery status indicator
(4) Push button
(9) Communication port
(5) System indicator
(6) BMS communication port
()7 Parallel communication port
()8 Monitor communication port
(10) DC switch
(11) PV terminal(12) Network communication port
2
3
4
5
55.0
KW
OutputPower
1
15
16
17
(17) Base
6
7
8
13
14
9
1011
12
40 in
40 in
40 in
40 in
1573 in.
22.62 in
PV
PCS
AC
Breaker
Phone
Meter
T
Grid
BAT
Primary Load
Load
Breaker
Load
Secondary Load
Bypass
Breaker
Grid

Oceń tę instrukcję

5.0/5 (2 Recenzje)

Specyfikacje produktu

Marka: Growatt
Kategoria: Niesklasyfikowane
Model: WIT 28-55K-HU-US L2

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Growatt WIT 28-55K-HU-US L2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Growatt

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

Smallrig
Qsc

QSC TSC-8 Instrukcja

29 Stycznia 2025
Xtrarm
Sunding
Xtrarm
Xtrarm
Osee

OSEE TX402 Instrukcja

29 Stycznia 2025