Invicta 3 Panelboard
630A / 800A
Invicta 3 Panelboard
630A / 800A
A panelboard with 630A/800A incoming and
125A/250A outgoing and a choice of glazed or
plain door.
Characteristics Invicta 3 Panelboards (630A/800A Incoming 125A Outgoing)
- Comprises of IP3XD enclosure, pan assembly, neutral bar and earth
bar.
- Conforms to BS EN 61439-2. InA = 630/800A, Inc = 125A, Icc = 50kA.
- Supplied without incoming kit, one of the incomer kits listed must be
used.
- Form 3B type 2 using outgoing terminal shield (form 3A without
terminal shield).
- Removable gland plates are provided top and bottom for ease of
installation.
- Switch Disconnector: 630A/800A, MCCB: 400A/630A, Direct
connection: 800A.
- Incoming cable lugged via M12 hexagonal bolt.
Cable Capacity Incomers & Outgoers
- Incomers: 400A: 2 x 240mm², 630A: 2 x 240mm² / 2 x 300mm².
- Outgoers: Single pole up to 125A - 70mm² exible, 95mm² solid, Triple
pole up to 250A - 150mm² exible.
Outgoing MCCBs
- Adjustable thermal options on triple pole.
Characteristics Invicta 3 Panelboards (630A/800A Incoming 125A/250A Outgoing)
- These boards will accept a range of MCCB frame sizes: 125A frame:
16-125A single pole/triple pole, 250A frame: 80-250A
- Triple pole only
- InA = 630/800A, Inc = 250A, Icc = 50kA.
Description
Invicta 3 Panelboards (630A/800A Incoming 125A Outgoing) Cat ref. Plain
Door
Cat ref. Glazed
Door
8 Triple Pole Ways 630A Panelboard JF608B JF608BG
12 Triple Pole Ways 630A/800A Panelboard JF812B JF812BG
18 Triple Pole Ways 630A/800A Panelboard JF818B JF818BG
The panelboard conforms to BS EN 61439-2 providing an efcient solution
for electrical distribution in commercial and industrial applications.
Outgoing moulded case circuit breakers from the x160 ranges are utilised
in this board.
Invicta 3 Panelboards (630A/800A Incoming 125A/250A Outgoing)
Cat ref. Plain
Door
Cat ref. Glazed
Door
6 Triple Pole Ways Panelboard (2 x 250A + 4 x 125A) JF60204B ¹ JF60204BG
1
8 Triple Pole Ways Panelboard (2 x 250A + 6 x 125A) JF80206B JF80206BG
8 Triple Pole Ways Panelboard (4 x 250A + 4 x 125A) JF80404B JF80404BG
12 Triple Pole Ways Panelboard (2 x 250A + 10 x 125A) JF80210B JF80210BG
12 Triple Pole Ways Panelboard (4 x 250A + 8 x 125A) JF80408B JF80408BG
18 Triple Pole Ways Panelboard (4 x 250A + 14 x 125A) JF80414B JF80414BG
18 Triple Pole Ways Panelboard (6 x 250A + 12 x 125A) JF80612B JF80612BG
1 Max allowed incomer of 630A on this panelboard
Specyfikacje produktu
| Marka: | Hager |
| Kategoria: | nieskategoryzowany |
| Model: | JF812BG |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Hager JF812BG, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje nieskategoryzowany Hager
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
Instrukcje nieskategoryzowany
- Alesis
- Fontastic
- Kubo
- Power Dynamics
- 8BitDo
- Pawa
- GeoVision
- Be Cool
- Audio Pro
- Cylinda
- Blizzard
- Bissell
- Taylor
- Match
- Core SWX
Najnowsze instrukcje dla nieskategoryzowany
28 Października 2024
28 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024