Technical Specications
• Supply Voltage 21...32 V DC SELV
• BUS Consumption Max 25mA
• Switching functions ON ; OFF ;
Pulse ; cycle ;
annual program
• Programming capacity 300 steps
Minimum time between 2 steps 1 min.
Clock generator Quartz, KNX Bus
or DCF signal (optional)
Power reserve Lithium battery
accumulation of 5 years of power outages
(unlimited backup of the program)
Accuracy (at 20° C) ≤ ± 0,25 sec /24 h
Screen High resolution LCD
(12,8 cm2)
Operating temperature -10 °C … +50 °C
Storage temperature -20 °C … +70 °C
• Ball test temperature
75°C … 125°C
Dimensions 4 modules ( 45 x 71,5 x 58 mm)
• Mounting DIN Rail (DIN EN 60715)
• Terminal Type Quick Connect
• Connection capacity
- Flexible : 0,75 to 2,5 mm2
- Rigid : 0,75 to 2,5 mm2
Protection index IP 20 / IK 04
• Protection Class II
• Standards EN 60730-1; EN 60730-2-7;EN 50491-3;
EN 50491-5-1; EN 50491-5-2; EN 50491-5-3
• DCF input Yes, with use of double-insulated cable
(DCF antenna EG001, optional)
Rated surge voltage 4kV
• Type of action 1
Pollution level 2
• Software structure Class A
• Product delivered with current time and date set.
• Automatic change of summer/winter time.
• Programming key
- For permanent overrides
- For program copy or save
300 programme steps ; ON, OFF, pulses or .
• Permanent overrides On or Off
( permanent light on).
Connection diagram
Product Presentation
Presentation
• Temporary overrides On or Off ( ashing).
• Overrides (temporary, permanent or time delayed)
remote activation possible.
• Simulation of presence .
• Keyboard lock function by PIN number.
• Counter of operating time on every output.
• Programmable with power off.
• Display with backlight.
First Commissioning
When using for the rst time, the following
settings must be done :
- select the language
- select the year, month, day
- select the hour and the minutes
- select the automatic change summer/winter.
Press the buttons to set the display.+/–
Press OK to validate.
When the settings are nished, the clock goes to
automatic mode.
In the event of use of DCF antenna EG001, it is not
possible to change the time zone of the DCF signal
either on the product or in the ETS application.
At any time, pressing the button menu allows you
to return to the previous choice level.
To do the yearly programming of the clock, you
have the following 4 types of programme:
-Basic weekly programme
This is a non-priority weekly programme.
-Sub-programmes 1 to 10
These are weekly sub-programmes which are
activated for a defined date-to-date period. As
the sub-programme number increases, so does
the priority.
-DATE/TIME
This is a programme step composed of a time
and a date which will run in addition to the usual
programme. If there is conflict between this
programme step and another programme step
(SP or weekly), this step has priority.
-Holidays
This programme allows you to define a
permanent ON or OFF from date-to-date.
This programme has the highest priority.
Pressing simultaneously the , , , keysmenu – + ok
allows you to réinitialize the product.
The program is kept in memory.
Press the button to access the programming/menu
setting mode.
All of the programming and adjustments are
based on the following principle :
- the 1st line and/or 2nd line of the display
indicate the requested setting,
- the buttons +/ allow navigation through the-
menus and settings,
- the button ok allows validation.
Pressing the button menu allows you to access
the following settings :
Navigation &
value setting
Validation
Enter in PROGRAMME mode &
return to previous step
S
election of days of the week
1 = Monday, 2 = Tuesday
... 7 = Sunday.
Canal B command
Canal C comman
d
Canal D command
Canal A command
D
CF Antenna (option)
Keyboard locked by PIN code
menu +ok
Reinitializing
Menu
Programming
PROGRAM SETTINGS FUNCTIONS
DATE-TIME
S/W TIME
LANGUAGE
FACTORY
SETTINGS
BACK
AUTO
PROGRAM
CREATE
PROGRAM
READ
PROGRAM
MODIFY
PROGRAM
DELETE
PROGRAM
COPY
BACK
AUTO
COUNTER
CYCLE
PIN CODE
BACK
AUTO
menu
6LE001666A1
z4 channel programmer
annual and weekly cycle
with programming key
User instructions
TYA720
6LE001666A
DCF antenna (optional)
Addressing button


Specyfikacje produktu

Marka: Hager
Kategoria: nieskategoryzowany
Model: TYA720

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Hager TYA720, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje nieskategoryzowany Hager

Hager

Hager VS418PZF Instrukcja

15 Sierpnia 2024
Hager

Hager VS318PZF Instrukcja

15 Sierpnia 2024
Hager

Hager VS218PZF Instrukcja

15 Sierpnia 2024
Hager

Hager TN204S Instrukcja

15 Sierpnia 2024
Hager

Hager TN206S Instrukcja

15 Sierpnia 2024
Hager

Hager EH171A Instrukcja

15 Sierpnia 2024
Hager

Hager EG203 Instrukcja

14 Sierpnia 2024
Hager

Hager EG403E Instrukcja

14 Sierpnia 2024
Hager

Hager M-RG404020 Instrukcja

14 Sierpnia 2024
Hager

Hager 80262160 Instrukcja

14 Sierpnia 2024

Instrukcje nieskategoryzowany

Najnowsze instrukcje dla nieskategoryzowany

Asko

Asko DBI644MIB.S.TW/1 Instrukcja

28 Października 2024
Asko

Asko DFS233IB.S.TW/1 Instrukcja

28 Października 2024
Emko

Emko EZM-9920 Instrukcja

27 Października 2024
Emko

Emko ESM-3712-H Instrukcja

27 Października 2024
Emko

Emko ATS-10 Instrukcja

27 Października 2024
Emko

Emko EAOM-11.2 Instrukcja

27 Października 2024
Emko

Emko EPM-3790 Instrukcja

27 Października 2024
Emko

Emko EPM-7790 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux IAN 108340 Instrukcja

27 Października 2024
Livarno Lux

Livarno Lux HG06009A-BS Instrukcja

27 Października 2024