Device layout (Fig. 1)
TYF642F
A1 A2 A3 A4 A5 A6 A7 A8
ALL OFF
ON /OFF/
L N
30Vs
A1-A8 µ 10A 1 230VAC
230-240V
TP / S
A1 A2A3 A4
A5A6 A7 A8
1Keypad for manual control
2Programming LED
3Programming button
4KNX connection
5Mains supply connection
6Status LED outputs
7Connexion of fan coil unit.
Operation
Controls (Fig. 2)
TYF642F
A1 A2 A3 A4 A5 A6A7 A8
ALL OFF
ON /OFF/
L N
TP / S
6status LED outputs
8key : manual control
9LED : permanent manual control
indicator
A key ON / 3: switching on
ZLED ON / : on, manual control3
E key OFF / : switching o 4
RLED OFF / : o , manual control4
Tkey ALL OFF: all outputs are o
Status indication
The status LEDs indicate the output states.A1...A8
LED o output is o
LED onoutput is on
LED fl ashing
slowly
output in manual control
mode
LED fl ashing
fast
output disabled by
permanent manual control
mode
Modes of operation
Bus operationoperation via touch sensors
or other bus devices
Temporary
manual control
manual operation locally with
keypad, automatic return to
bus operation
Permanent
manual control
mode
only manual operation locally
on device
H• Bus operation in manual control mode
disabled.
• Manual operation in the event of bus failure
enabled.
• After failure and return of bus voltage, the
device switches over to bus operation.
• After failure and return of mains voltage, the
device switches over to bus operation.
• Manual control mode can be disabled in
operation via bus telegram.
Activating the temporary manual control mode
Keypad operation has been programmed
beforehand and is not disabled.
- Press the key.
LED A1 fl ashing, LED remains o .
HAfter 5 s without key-press, the actuator
returns automatically to the bus mode.
Deactivating the temporary manual control
mode
The device must be in the temporary manual
control mode.
- No key-press for 5 s.
or
- press the key repeatedly until the actuator quits
the temporary manual control mode.
LEDs A1...A8 are no longer fl ashing, but indicating
the output status.
• Heating/cooling outputs: on deactivation of the
manual mode, the outputs switch into the position
then active, e.g. forced control (depending on
programming).
• Fan outputs :on deactivation of the manual mode,
Safety instructions
Function
System information
This device is a product of the KNX system and
complies with KNX directives. Detailed technical
knowledge obtained in KNX training courses is a
prerequisite to proper understanding.
The functionality of this device depends on the
software. Detailed information on loadable software
and attainable functionality as well as the software
itself can be obtained from the manufacturer‘s
product database.
Planning, installation and commissioning of
the unit is e ected by means of KNX-certifi ed
software. The full functionality is available with
KNX commissioning software from version ETS3.0f
onwards.
The product database, technical descriptions,
conversion programs and other utilities are
available in their latest version on our Internet page.
Designated use
• Switching of electrical fan coil units
• Switching of electrical AC 230 V consumers, e.g.
fans
• Mounting on DIN rail in xed installations (power
distributions or small boxes).
Product features
• Connection of a fan coil unit with up to 6 fan
stages or connection of fan coil units with up to 3
fan stages respectively
• Manual output control, provisional operation
• Control options for heating, cooling or combined
heating/cooling operation
• 2-pipe or 4-pipe operation
• Individual or hierarchical switching of fan stages
• Feedback
• Output state indication
• Disable function for each channel
A1 A2 A3 A4
A5 A6 A7 A8
TYF642F
A1 A2 A3 A4A5 A6 A7 A8
ALL OFF
ON
/OFF
/
LN
30Vs
A1-A8 µ 10A AC1 230V
230-240V
TP / S
:.,nB
tebis
zDual fan coil actuator
rActuador de ventilo-convectores,
2 canales
6LE004143A
1 6LE004143A
q• Electrical equipment must be installed
and fi tted by qualifi ed electricians
only. Observe the current accident
prevention regulations.
• Failure to observe the instructions may
cause damage to the device
and result in fi re or other hazards.
• The device is not suited for safe
disconnection of the mains supply.
• Do not connect consumers
for SELV / PELV voltages.
• Do not connect three-phase AC
motors.
• These operating instructions are part
of the product and must be left with
the fi nal customer.
TYF642F
Specyfikacje produktu
| Marka: | Hager |
| Kategoria: | nieskategoryzowany |
| Model: | TYF642F |
| Kolor produktu: | Szary |
| Wysokość produktu: | 90 mm |
| Szerokość produktu: | 72 mm |
| Głębokość produktu: | 70 mm |
| Zakres temperatur (eksploatacja): | -5 - 45 °C |
| Stopień ochrony IP: | IP20 |
| Liczba dołączonych produktów: | 1 szt. |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Hager TYF642F, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje nieskategoryzowany Hager
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
Instrukcje nieskategoryzowany
Najnowsze instrukcje dla nieskategoryzowany
28 Października 2024
28 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024