Instrukcja obsługi Hager WGCHKTM
Hager
nieskategoryzowany
WGCHKTM
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Hager WGCHKTM (4 stron) w kategorii nieskategoryzowany. Ta instrukcja była pomocna dla 18 osób i została oceniona przez 9.5 użytkowników na średnio 4.8 gwiazdek
Strona 1/4

www.hager.com
Safety instructions
Electrical equipment must only be installed and assembled by a qualied
electrician in accordance with the relevant installation standards, regulations,
directives and safety and accident prevention directives of the country.
Failure to comply with these installation instructions may result in damage to
the device, re or other hazards.
Function
The key card switch is used for central switching on of electric loads by inserting a
key card as well as for storage of the key card. The key card switch is installed in the
entrance area. When the key card is removed the connected loads will be switched
o automatically after the delay time has expired (approx. 30 seconds) and the LED
orientation light of the key card switch is switched on.
The key card switch RFID works exclusively with the RFID key card programmed
for this purpose.
16A key card switch - mechanical
16A key card switch - RFID
Hager Muse / Hager Inspire
Installation and operating
instructions

2
Correct use
- Switching of incandescent lamps, high-voltage halogen lamps,uorescent lamps,
230 V LED lamps as well as dimmable electronic transformers (marked with L, C)
with halogen lamps.
- For the ush-mounted installation in standard wall boxes
(recommended wall box depth ≥ 35 mm).
- Only suitable for use in indoor areas with no drip and no spray water.
Technical data
Rated voltage: 230 V~
Frequency: 50/60 Hz
Rated current: 16 A
Delay time: 30 s (+/- 10 s)
Power consumption (standby): < 1.5 W
Contact type: relay, 1 normally-open contact
Conductor cross-section of screw terminals: max. 3 x 1.5 mm²
Distance of fixing holes: 60.3 mm
Operating temperature: -5 ... +45°C
Relative humidity (without condensation): 5 ... 95 % (at 25 °C)
Standards: BS EN 60669-2-1, IEC 60669-2-1
WARNING!
To avoid possible damage to the product or spurious insulation
readings, please DISCONNECT the product before carrying out
insulation resistance testing!
ç
Information for electricians
Installation and electrical connection
DANGER!
Touching live parts can result in an electric shock.
An electric shock can lead to death.
Disconnect the connecting cables before working on the device and
cover all live parts in the area!
ç

3
Preparing the device for installation
1
Frame
Key card module
Notches Switch
insert
Loosen the frame on the notches with a at-blade screwdriver ( ).1
Carefully remove the key card module from the switch insert.
Connecting the device
L LOAD N
L
N
E
2A
L LOAD N
L3
N
E
L2
L1
2B
Strip connection cables approx. 12 mm.
Connect key card switch for direct switching of loads according to connecting
diagram ( ). Can be installed alternatively with a load contactor ( ).2A 2B
Specyfikacje produktu
Marka: | Hager |
Kategoria: | nieskategoryzowany |
Model: | WGCHKTM |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Hager WGCHKTM, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje nieskategoryzowany Hager
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
15 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
14 Sierpnia 2024
Instrukcje nieskategoryzowany
- nieskategoryzowany Murr Elektronik
- nieskategoryzowany Robinhood
- nieskategoryzowany 8BitDo
- nieskategoryzowany Prestigio
- nieskategoryzowany Urbanista
- nieskategoryzowany Noctua
- nieskategoryzowany Eller
- nieskategoryzowany Ferplast
- nieskategoryzowany Hendi
- nieskategoryzowany Casaria
- nieskategoryzowany Bresser
- nieskategoryzowany Daewoo
- nieskategoryzowany Flama
- nieskategoryzowany Orava
- nieskategoryzowany Dynacord
Najnowsze instrukcje dla nieskategoryzowany
28 Października 2024
28 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024
27 Października 2024