Installation Instructions
Electronic pressure sensor
for industrial applications
PC3541
PC3542
704775 / 00 04 / 2010
UK

2
1 Safety instructions
Please read this document prior to installing the unit. Ensure that the product is •
suitable for your application without any restrictions.
If the operating instructions or the technical data are not adhered to, personal •
injury and/or damage to property may occur.
Please check for all applications that the product materials (see Technical data) •
are compatible with the media to be measured.
For the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated either
a) max 5 amps for voltages 0~20 Vrms (0~28.3 Vp) or
b) 100/Vp for voltages of 20~30 Vrms (28.3~42.4 Vp).
Contents
1 Safety instructions ................................................................................................2
2 Function and features ...........................................................................................3
2.1 Applications ....................................................................................................3
3 Installation ............................................................................................................3
4 Electrical connection.............................................................................................4
5 Scale drawing .......................................................................................................4
6 Technical data .......................................................................................................5

3
UK
2 Function and features
The pressure sensor detects the system pressure and converts it into an analog
output signal.
4 ... 20 mA•
2.1 Applications
Type of pressure: relative pressure •
Order no. Measuring range Permissible
overload pressure
Bursting
pressure
bar PSI bar PSI bar PSI
PC3541 0...250 0...3 625 400 5 800 1 000 14 504
PC3542 0...100 0...1 450 200 2 900 1 000 14 504
MPa = bar ÷ 10 / kPa = bar × 100
Static and dynamic overpressures exceeding the indicated overload pres-
sure are to be avoided by taking appropriate measures.
The indicated bursting pressure must not be exceeded. Even if the burst-
ing pressure is exceeded only for a short time, the unit can be destroyed.
NOTE: Risk of injury!
3 Installation
Before mounting and removing the sensor, make sure that no pressure is
applied to the system.
Insert the unit in a G¼ process connection. ►
Tighten firmly. T ightening torque: max. 25 Nm. ►
Specyfikacje produktu
Marka: | IFM |
Kategoria: | Niesklasyfikowane |
Model: | PC3541 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z IFM PC3541, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane IFM
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
28 Stycznia 2025
Instrukcje Niesklasyfikowane
- Niesklasyfikowane Jamo
- Niesklasyfikowane Ambient Weather
- Niesklasyfikowane Bēm Wireless
- Niesklasyfikowane Taco Tuesday
- Niesklasyfikowane BASSBOSS
- Niesklasyfikowane Yeyian
- Niesklasyfikowane DeepCool
- Niesklasyfikowane Valueline
- Niesklasyfikowane Crouzet
- Niesklasyfikowane JAR Systems
- Niesklasyfikowane Perfecta
- Niesklasyfikowane Assa Abloy
- Niesklasyfikowane Schwaiger
- Niesklasyfikowane Aqua Medic
- Niesklasyfikowane Cosina
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025