Operating instructions
Evaluation system for flow sensors
SR0152
704949 / 01 07 / 2013
UK
2
1 Preliminary note
The operating instructions are part of the unit. They contain information about the
correct handling of the product. Read them before use to get familiar with operat-
ing conditions, mounting and operation. Adhere to the safety instructions. The
operating instructions are made for authorised persons according to the EMC and
low voltage guidelines.
Contents
1 Preliminary note 2 ...................................................................................................
2 Safety instructions 3 ...............................................................................................
3 Function and features 4 ..........................................................................................
4 Mounting ..............................................................................................................4
4.1 Mounting of the sensors 5 ................................................................................
5 Electrical connection 5 ............................................................................................
5.1 Terminal connection 6 .......................................................................................
5.2 Power supply (Power) 6 ..................................................................................
5.3 Connection of sensors 7 ...................................................................................
5.4 Relay outputs 7 ................................................................................................
6 Settings ...............................................................................................................7
7 Operation ............................................................................................................8
7.1 Function diagram flow monitoring 8 .................................................................
8 Maintenance, repair, disposal 9 .............................................................................
9 Technical data and scale drawing 9 ........................................................................
3
UK
2 Safety instructions
鈥㈩槂 Adhere to the operating instructions. Non-observance of the instructions,
operation which is not in accordance with use as prescribed below, wrong in-
stallation or incorrect handling can affect the safety of operators and machinery.
鈥㈩槂 The unit must only be installed, connected and put into operation by a qualified
electrician as during the installation dangerous voltages may be exposed. The
safe function of the unit and the plant is only guaranteed when installation is
correctly carried out.
鈥㈩槂 Disconnect the unit externally before handling it. Also disconnect any indepen-
dently supplied relay load circuits.
鈥㈩槂 Be careful when handling the unit once power is applied. This is only allowed
by qualified personnel due to the protection rating IP 20.
鈥㈩槂 The design of the unit corresponds to protection class II (EN 61010) except for
the terminal blocks. Protection against accidental contact (safety from finger
contact to IP20) for qualified personnel is only ensured if the terminals have
been completely inserted. For this reason the unit must always be installed in a
control cabinet which can only be opened with a tool, for pollution degree 2 and
overvoltage category II.
鈥㈩槂 For DC units the external 24 V DC supply must be generated and supplied ac-
cording to the requirements for safe extra-low voltage (SELV) since this voltage
is provided near the operating elements and at the terminals for the supply of
sensors without further protection measures.
鈥㈩槂 In case of malfunction of the unit or queries please contact the manufacturer.
Any tampering with the device can seriously affect the safety of operators and
machinery. This is not permitted and leads to an exclusion of liability and war-
ranty.