Instrukcja obsługi IQAir Perfect 16
IQAir
oczyszczacz powietrza
Perfect 16
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla IQAir Perfect 16 (12 stron) w kategorii oczyszczacz powietrza. Ta instrukcja była pomocna dla 19 osób i została oceniona przez 10 użytkowników na średnio 3.6 gwiazdek
Strona 1/12

IQAir® Perfect 16™ID-Series
MERV16 Micro-Particle Filtration System
Perfect 16
Installation Manual

Application
The Perfect 16 ID Series is a V-bank filter system that connects to the return air duct or supply air duct of a forced air system.
This Residential / Commercial Air Filtration System has been designed to provide the highest possible air cleaning rate at the
lowest possible pressure drop for residential and commercial forced air systems.Two models are available. The ID-2225 is ideal
for airflow rates up to 1200 cfm (2040 m3/h) and the ID-2530 for airflow rates up to 2000 cfm (3400 m3/h).
Features
• Ultra efficient: MERV16 certified (ASHRAE 52.2)
• Low air resistance: 0.22 “w.c. ( 54 Pa) at rated airflow
• Long filter life: 3 years in average home use
• Quick and easy filter replacement: No tools needed
• Easy installation: Requires no electrical connections
• Rugged steel cabinet: Supports weight of furnace
• Medical grade finish: Powder coated galvanized steel
• Fully insulated for installation in unconditioned environments
• Swiss made quality: 10 year warranty
Product Data
High-Performance Medical-Grade Residential/Commercial
Air Filtration System
System All measurements in inch (mm)
W
H
L
ID-2225: Provide 24 1/2 (622) service clearance in front of unit.
ID-2530: Provide 28 1/2 (721) service clearance in front of unit.
Page 2

Performance Data
Usage vs. Resistance
Average home based on 50% duty cycle
ID-2225 at 1200 cfm ID-2530 at 2000 cfm
in H2O Pa in H2O Pa
new 0.18 44 0.22 54
3 months 0.18 45 0.22 55
6 months 0.19 47 0.23 57
9 months 0.20 50 0.24 60
12 months 0.21 53 0.26 64
15 months 0.22 56 0.28 70
18 months 0.24 59 0.31 78
21 months 0.25 62 0.35 87
24 months 0.26 66 0.39 97
27 months 0.28 71 0.44 110
30 months 0.31 77 0.50 125
33 months 0.34 85 0.57 142
36 months 0.38 94 0.64 161
Minimum Efficiency Reporting Data
ID-2225 ID-2530
Minimum Efficiency Reporting
Value (MERV) MERV 16@492 fpm (2.5m/s) MERV 16@492 fpm (2.5 m/s)
Rated airflow 1400 cfm (2380 m3/h) 2000 cfm (3400 m3/h)
Composite Average Efficiency
E1 (0.3 – 1.0 µm) = 96.7%
E2 (1.0 – 3.0 µm) = 97.7%
E3 (3.0 – 10.0 µm) = 98.5%
E1 (0.3 – 1.0 µm) = 95.9%
E2 (1.0 – 3.0 µm) = 97.3%
E3 (3.0 – 10.0 µm) = 98.3%
Media area 170 sq.ft. (15.8 m2/h) 210 sq.ft. (19.5 m2/h)
Airflow vs. Filter System Resistance
ID-2225 ID-2530
cfm (m3/h) in H2O Pa in H2O Pa
600 (1020) 0.06 14 0.03 8
800 (1360) 0.09 21 0.04 12
1200 (2040) 0.18 44 0.10 24
1600 (2720) 0.33 82 0.15 38
2000 (3400) 0.49 122 0.22 54
ID-2225
ID-2530
Based on ASHRAE 52.2 Air Cleaner Performance Reports from Intertek Testing
Services (ETL SEMKO), Cortland, NY
Page 3
Filter Usage
Specyfikacje produktu
Marka: | IQAir |
Kategoria: | oczyszczacz powietrza |
Model: | Perfect 16 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z IQAir Perfect 16, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje oczyszczacz powietrza IQAir
2 Października 2024
23 Września 2024
16 Września 2024
8 Września 2024
3 Września 2024
2 Września 2024
18 Sierpnia 2024
16 Sierpnia 2024
Instrukcje oczyszczacz powietrza
- Dyson
- Finlux
- JML
- AlorAir
- EZIclean
- Vicks
- Haus Luft
- Dirt Devil
- Hamilton Beach
- TruSense
- Stadler Form
- Electrolux
- P3 International
- Meross
- Alen
Najnowsze instrukcje dla oczyszczacz powietrza
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
7 Kwietnia 2025
7 Kwietnia 2025
6 Kwietnia 2025
6 Kwietnia 2025
5 Kwietnia 2025
5 Kwietnia 2025
5 Kwietnia 2025