User instructions
Transmitted light phase contrast microscope
KERN L-14, OBL-15 OB
OBL 146, OBL 155, OBL 156
Version 1.2
01 20/ 23

OBL- - - -e-2 2 14 15 BA 312
GB
KERN OBL-14, OBL- 15
Version 2 /2023 1. 01
User instructions
Phase contrast microscope
Table of contents
1 Before use .................................................................................... 3
1.1 General notes ............................................................................................................................ 3
1.2 Notes on the electrical system ................................................................................................ 3
1.3 Storage ...................................................................................................................................... 4
1.4 Maintenance and cleaning ....................................................................................................... 5
2 Nomenclature ............................................................................... 6
3 Technical data / Features ............................................................ 8
4 Assembly .................................................................................... 10
4.1 Microscope head .................................................................................................................... 10
4.2 Objectives ............................................................................................................................... 10
4.3 Eyepieces ................................................................................................................................ 10
4.4 Colour 顙噇ter ............................................................................................................................. 10
4.5 PH condenser + PH slide ....................................................................................................... 11
5 Operation .................................................................................... 11
5.1 Getting started ........................................................................................................................ 11
5.2 (Pre-) focussing ...................................................................................................................... 12
5.3 Adjusting the interpupillary distance ................................................................................... 13
5.4 Dioptre adjustment ................................................................................................................. 13
5.5 Adjusting the magni顙嘽ation .................................................................................................. 14
5.6 Adjusting the Koehler illumination ....................................................................................... 15
5.7 Using eye cups ....................................................................................................................... 17
5.8 Using oil immersion objectives ............................................................................................ 18
5.9 Phase contrast unit ................................................................................................................ 19
6 Changing the bulb .....................................................................21
7 Changing the fuse ...................................................................... 22
8 Using optional accessories ....................................................... 22
8.1 Camera connection ................................................................................................................ 22
9 Trouble shooting ........................................................................ 23
10 Service ........................................................................................ 25
11 Disposal ...................................................................................... 25
12 Further information .................................................................... 25

3 - - - -e-2 OBL 14 15 BA 312
1 Before use
1.1 General notes
You must open the packaging carefully, to make sure that none of the accessories in
the packaging fall on the 顙坥or and get broken.
In general, microscopes should always be handled carefully because they are sensitive
precision instruments. When using or transporting the microscope it is particularly
important to avoid abrupt movements, as this may damage the optical components.
You should also avoid getting dirt or 顙噉ger prints on the lens surface, because in most
cases this will reduce image clarity.
To maintain the performance of the microscope, it must never be disassembled. So
components such as lenses and other optical elements should be left as they were
before use. Also the electrical parts on the rear and base of the device must not be
tampered with, as in this area there is an additional risk of triggering an electric shock.
1.2 Notes on the electrical system
Before connecting to a mains power supply, you must make sure that you are using
the correct input voltage. The information to select the correct mains cable is located
on the device, on the rear of the product directly above the connection socket. You
must comply with this information. If you do not comply with these speci顙嘽ations, then
顙噐es or other damage to the device could occur.
The main switch must also be switched off before the mains cable is connected. In this
way you will avoid triggering an electric shock.
If you are using an extension cable, then the mains cable you use must be earthed.
If the original fuse should blow, it must only be replaced by an appropriate fuse.
Suitable replacement fuses are included with the delivery.
When carrying out any procedures whereby you come into contact with the electrical
system of the device, such as, for example, changing the bulb or fuse, only carry out
these procedures when the power is disconnected.
Specyfikacje produktu
Marka: | Kern |
Kategoria: | mikroskop |
Model: | OBL 156 |
Potrzebujesz pomocy?
Je艣li potrzebujesz pomocy z Kern OBL 156, zadaj pytanie poni偶ej, a inni u偶ytkownicy Ci odpowiedz膮
Instrukcje mikroskop Kern

9 Kwietnia 2025

1 Kwietnia 2025

1 Kwietnia 2025

1 Kwietnia 2025

1 Kwietnia 2025

1 Kwietnia 2025

1 Kwietnia 2025

1 Kwietnia 2025

30 Marca 2025

30 Marca 2025
Instrukcje mikroskop
- mikroskop Leica
- mikroskop Toolcraft
- mikroskop Nikon
- mikroskop National Geographic
- mikroskop Maginon
- mikroskop Carson
- mikroskop Bresser
- mikroskop Hama
- mikroskop Swift
- mikroskop Levenhuk
- mikroskop Steinberg
- mikroskop Dino-Lite
- mikroskop Vivitar
- mikroskop Zeiss
- mikroskop Reflecta
- mikroskop Celestron
- mikroskop Barska
- mikroskop Veho
- mikroskop Dnt
- mikroskop Traveler
- mikroskop Ideal Tek
- mikroskop Discovery
- mikroskop PCE Instruments
- mikroskop BeaverLab
- mikroskop National Optical
Najnowsze instrukcje dla mikroskop

2 Kwietnia 2025

2 Kwietnia 2025

30 Marca 2025

27 Marca 2025

1 Lutego 2025

1 Lutego 2025

10 Stycznia 2025

8 Stycznia 2025

16 Grudnia 2024

13 Grudnia 2024