Instrukcja obsługi Klein Tools CL120KIT
Klein Tools
Sprzęt pomiarowy
CL120KIT
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Klein Tools CL120KIT (25 stron) w kategorii Sprzęt pomiarowy. Ta instrukcja była pomocna dla 19 osób i została oceniona przez 10 użytkowników na średnio 4.7 gwiazdek
Strona 1/25

INSTRUCTION MANUAL
600V
400A
20M
Ω
FRANÇAIS pg. 33
ESPAÑOL pg. 17
400A AC Au
Digital Clam
• NON-CONTACT
VOLTAGE TESTING
• AUTO-RANGING
• DATA HOLD
• RANGE HOLD
• AUDIBLE
CONTINUITY
ENGLISH
CL120KIT
2m
CAT III
600V

2
GENERAL SPECIFICATIONS
Klein Tools CL120 is an automatically ranging digital clamp-meter
that measures AC current via the clamp, and AC/DC voltage,
resistance and continuity via test-leads.
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <95% non-condensing
• Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
• Storage Temp: ° ° ° °14 to 122 F (-10 to 50 C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Temp Coefcient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
• Dimensions: 8.46" x 3.54" x 1.50" (215 x 90 x 38 mm)
• Weight: 11.04 oz. (313 g) including batteries
• Calibration: Accurate for one year
• Auto Power-Off (APO): After approx. 10 minutes of inactivity
• Standards: IEC EN 61010-1, 61010-2-032, 61010-2-033.
IEC EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1,
61010-2-032,61010-2-033;
Certified to CSA STD.C22.2 NO. 61010-1,
61010-2-032,61010-2-033.
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CATIII 600V, Class 2, Double insulation
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH

4
ENGLISH
WARNINGS - GENERAL
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use verify meter operation by measuring a known voltage
or current.
• Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Use only with CAT III or CAT IV rated test leads.
• Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes are connected.
• Use caution when working with voltages above 25V AC RMS or 60V DC.
Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace batteries
when a low battery indicator appears.
• Do not attempt to measure resistance or continuity on a live circuit.
• Always adhere to local and national safety codes. Use personal protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.
WARNINGS - NCV FUNCTION
• When NCV Function is initiated, a blinking or steady red glow and an audible
beep indicate voltage present. If no indication, voltage could still be present.
• Before and after each use of the NCVT, verify operation by testing a known
working circuit that is within the rating of this unit.
• Never assume neutral or ground wires are de-energized. Neutrals in multi-wire
branch circuits may be energized when disconnected and must be retested
before handling.
• The NCV tester WILL NOT detect voltage if:
• The wire is shielded.
• The
operator is not grounded or is otherwise isolated from an effective earth ground.
• The voltage is DC.
• The NCV tester MAY NOT detect voltage if:
• The user is not holding the tester.
• The user is insulated from the tester with a glove or other materials.
• The wire is partially buried or in a grounded metal conduit.
• The tester is at a distance from the voltage source.
• The field created by the voltage source is blocked, dampened, or otherwise
interfered with.
• The frequency of the voltage is not a perfect sine wave between 50 and 500Hz.
• The tester is outside of operation conditions (listed in Specifications section).
• Operation may be affected by differences in socket design and insulation
thickness and type; tester may not be compatible with some types of standard
or tamper resistant (TR) electrical outlets.
• Do not apply to uninsulated hazardous live conductors.
• Detection above 50V is specified under “normal” conditions as specified below.
The tester may detect at a different threshold at different conditions, or may not
detect at all unless:
• The
tip of the tester is within 0.25" of an AC voltage source radiating unimpeded.
• The user is holding the body of the tester with his or her bare hand.
• The user is standing on or connected to earth ground.
• The air humidity is nominal (50% relative humidity).
• The tester is held still.
Specyfikacje produktu
Marka: | Klein Tools |
Kategoria: | Sprzęt pomiarowy |
Model: | CL120KIT |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Klein Tools CL120KIT, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Sprzęt pomiarowy Klein Tools
14 Stycznia 2025
14 Stycznia 2025
1 Stycznia 2025
27 Grudnia 2024
9 Października 2024
9 Października 2024
9 Października 2024
6 Października 2024
6 Października 2024
5 Października 2024
Instrukcje Sprzęt pomiarowy
- Sprzęt pomiarowy Werma
- Sprzęt pomiarowy Testboy
- Sprzęt pomiarowy MSW
- Sprzęt pomiarowy Milesight
- Sprzęt pomiarowy Black & Decker
- Sprzęt pomiarowy Albrecht
- Sprzęt pomiarowy NEO Tools
- Sprzęt pomiarowy Bresser
- Sprzęt pomiarowy Pico
- Sprzęt pomiarowy Pancontrol
- Sprzęt pomiarowy Water-i.d.
- Sprzęt pomiarowy DriveTest
- Sprzęt pomiarowy Pioneer
- Sprzęt pomiarowy CESYS
- Sprzęt pomiarowy GMW
Najnowsze instrukcje dla Sprzęt pomiarowy
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025