Instrukcja obsługi Klein Tools IR10
Klein Tools
termometr
IR10
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Klein Tools IR10 (32 stron) w kategorii termometr. Ta instrukcja była pomocna dla 18 osób i została oceniona przez 9.5 użytkowników na średnio 4.8 gwiazdek
Strona 1/32

IR10
FRANÇAIS p. 21
ESPAÑOL pg. 11
• DUAL-LASER
TARGETING
• 20:1 DISTANCE-
TO-SPOT RATIO
• ADJUSTABLE
EMISSIVITY
• K-TYPE PROBE
MEASUREMENTS
• AUTO-SCAN
• MAX/MIN/AVG/DIFF
• HIGH/LOW AUDIBLE &
VISUAL ALARMS
• BACKLIT DISPLAY
• AUTO POWER-OFF
ENGLISH
-40° – 1200° F
(-40° – 650° C)
INSTRUCTION MANUAL
Dual-laser Infrared
Thermometer
3
m IP54

2
GENERAL SPECIFICATIONS
Klein Tools IR10 is a professional dual-laser targeting infrared (IR)
thermometer. It offers a wide measurement range, a tight distance-
to-spot ratio, dual targeting lasers, and several calculation modes to
facilitate different temperature measurement applications. In addition
to measuring temperature using IR emission it can also measure
temperature using a standard K-type probe.
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <85% non-condensing
• Operating Temp: ° ° ° °32 to 122 F (0 to 50 C)
• Storage Temp: ° ° ° °-4 to 140 F (-20 to 60 C)
• Measurement Range: -40°F to 1200°F (-40°C to 650°C)
• Units: Settable to °F or °C
• Emissivity: 0.10-1.00 adjustable
• Optical Resolution (Distance-to-spot): 20:1
• Dimensions: 7" x 4.49" x 2.05" (178 x 114 x 52 mm)
• Weight: 9.1 oz. (256 g) including battery
• Battery Type: 1 x 9V battery
• Battery Life: (Estimates assume 9V alkaline battery)
8 hours continuous infrared measurement
w/laser and backlight on
• Display: Backlit LCD
• Display Resolution: 0.1°F (0.1° C)
• Calibration: Accurate for one year
• K-Type Probe: Included probe suitable for -40°F to 356°F
(-40°C to 180°C)
• Lasers: FDA and IEC Class II, <1mW each laser, 630-670nm
• Standards:
Conforms to IEC EN 61326-1:2013,EN608251:2014
Complies with: 21 CFR 1040.10 and 1040.11 except for
deviations pursuant to laser notice No. 50, dated June 24, 2007
• Pollution Degree: 2
• Ingress Protection: IP54 dust & water resistant
• Drop Protection: 9.8 ft. (3m)
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH

3
MEASUREMENT SPECIFICATIONS
Specication IR Measurement K-Type Measurement
Range -40°F to 1200°F
(-40°C to 650°C)
-40°F to 1200°F
(-40°C to 650°C)
Accuracy
≥32°F (0°C): ±3°F (±1.5°C)
or ± 1.5% whichever is
greater
<32°F (0°C):
±(3.6°F + 0.2°F per degree)
(±(2°C + 0.2°C per degree))
≥32°F (0°C): ±2°F (±1°C)
or ±1%, whichever is
greater
<32°F (0°C): ±3°F (±1.5°C)
or ±1%, whichever is
greater
Repeatability ±0.8% or ±2F(±1C),
whichever is greater
±0.5% or ±1F (±0.5C),
whichever is greater
Spectral
Response 8-14µm N/A
Response
Time <150ms <150ms
Data Hold Yes Yes
MAX/MIN/
Average/
Differential
Yes Yes
Measurement
out of range ‘----‘ on display ‘----‘ on display
Temperature
Correction
Coefcient
Temperature Correction Coefficient: ±0.2°F per °F
(±0.1°C per °C), or ±0.2% of reading (whichever
is greater) when ambient temperature is above or
below 70 – 77°F (21 – 25°C).
Specifications subject to change.
NOTE: The included K-type probe is suitable ONLY for
temperatures of -40°F to 356°F (-40°C to 180°C). For
temperatures above 356°F (180°C), a high-temp K-Type
probe is required.
Specyfikacje produktu
Marka: | Klein Tools |
Kategoria: | termometr |
Model: | IR10 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Klein Tools IR10, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje termometr Klein Tools
30 Września 2024
28 Września 2024
28 Września 2024
Instrukcje termometr
- termometr Optex
- termometr Amprobe
- termometr Elta
- termometr Homedics
- termometr Sencor
- termometr Melissa
- termometr Knikker
- termometr Save Demp
- termometr Comelec
- termometr Kerbl
- termometr Duronic
- termometr AEG
- termometr Bintoi
- termometr Cofoe
- termometr BeSafe
Najnowsze instrukcje dla termometr
8 Kwietnia 2025
7 Kwietnia 2025
6 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
3 Kwietnia 2025
2 Kwietnia 2025
2 Kwietnia 2025
2 Kwietnia 2025
1 Kwietnia 2025