INSTRUCTIONMANUAL
KEW 8146/8147/8148
LEAKAGE CLAMP SENSOR
Series
KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD.,
TOKYO, JAPAN
KEW
8146
KEW
8147
KEW
8148
1. Safety warnings
Thisinstrumenthasbeendesigned,manufacturedand
testedaccordingtoIEC
61010
:Safetyrequirementsfor
ElectronicMeasuringapparatus,anddeliveredinthebest
conditionafterpassingqualitycontroltests.This
instructionmanualcontainswarningsandsafetyrules
whichhavetobeobservedbytheusertoensuresafe
operationoftheinstrumentandtomaintainitinsafe
condition.Therefore,readthroughtheseoperating
instructionsbeforeusingtheinstrument.
# WARNING
Readthroughandunderstandinstructionscontainedin
thismanualbeforeusingtheinstrument.
Keepthemanualathandtoenablequickreference
whenevernecessary.
Theinstrumentistobeusedonlyinitsintended
applications.
Theoperatinginstructionsdescribedinthemanualmust
beobserved.
Understandandfollowallthesafetyinstructions
containedinthemanual.
Itisessentialthattheaboveinstructionsareadheredto.
Failuretofollowtheaboveinstructionsmaycauseinjury
andorinstrumentdamage.
Kyoritsuisbynomeansliableforanydamageresulting
fromtheinstrumentincontradictiontothiscautionary
note.
Thesymbol
#
indicatedontheinstrument,meansthat
theusermustrefertotherelatedpartsinthemanualfor
safeoperationoftheinstrument.Itisessentialtoreadthe
instructionswhereverthe
#
symbolappearsinthe
manual.
#
DANGER
isreservedforconditionsandactionsthat
arelikelytocauseseriousorfatalinjury.
#
WARNING
isreservedforconditionsandactions
thatcancauseseriousorfatalInjury.
#
CAUTION
isreservedforconditionsandactionsthat
cancauseminorinjuryorinstrumentdamage.
#
DANGER
Nevermakemeasurementonacircuitinwhichthe
electricalpotentialexceedsAC
300
V.
Donotmakemeasurementwhenthunderrumbling.Ifthe
instrumentisinuse,stopthemeasurementimmediately
andremovetheinstrumentfromthemeasuredobject.
Donotattempttomakemeasurementinthepresenceof
flammablegasses.Otherwise,theuseoftheinstrument
maycausesparking,whichcanleadtoanexplosion.
Thetransformerjawsaremadeofmetalandtheirtips
arenotcompletelyinsulated.Beespeciallycareful
aboutthepossibleshortingwherethemeasuredobject
hasexposedmetalparts.
Neverattempttousetheinstrumentifit'ssurfaceor
yourhandarewet.
Donotexceedthemaximumallowableinputofany
measuringrange.
# WARNING
Neverattempttomakeanymeasurement,ifany
abnormalconditionsarenoted,suchasbrokencase,
andexposedmetalparts.
Donotinstallsubstitutepartsormakeanymodification
totheinstrument.
Returntheinstrumenttothedistributorfromwhoyou
purchasedthisinstrumentforrepairorre-calibrationin
caseofsuspectedfaultyoperation.
Alwayskeepyourfingersandhandsbehindthebarrier
ontheinstrumenttoavoidthepossibleshockhazard.
# CAUTION
Donotsteponorpinchthecordtopreventthejacketof
cordfrombeingdamaged.

Theoutputconnectorshallberemovedorconnected
withoutclampingaconductor.Otherwise,itmaycause
afailure.
Donotexposetheinstrumenttodirectsunlight,high
temperatures,humidityordew.
Nevergiveshocks,suchasvibrationordrop,whichmay
damagetheinstrument.
Useadampclothanddetergentforcleaningthe
instrument.Donotuseabrasivesorsolvents.
Safetysymbols
Incoming wire
:
Device which is
not directly
connected to the
mains power supply
Socket
Interior wiring
MeasurementCategory:
Toensuresafeoperationofmeasuringinstruments,
IEC
61010
establishessafetystandardsforvarious
electricalenvironments,categorizedasOtoCATIV,
andcalledmeasurementcategories.Higher-numbered
categoriescorrespondtoelectricalenvironmentswith
greatermomentaryenergy,soameasuringinstrument
designedforCATIIIenvironmentscanenduregreater
momentaryenergythanonedesignedforCATII.
O:Circuitswhicharenotdirectlyconnectedtothe
mainspowersupply.
CATII:Electricalcircuitsofequipmentconnectedtoan
ACelectricaloutletbyapowercord.
CATIII:Primaryelectricalcircuitsoftheequipment
connecteddirectlytothedistributionpanel,and
feedersfromthedistributionpaneltooutlets.
CATIV:Thecircuitfromtheservicedroptotheservice
entrance,andtothepowermeterandprimary
over-currentprotectiondevice(distribution
panel).
 2. Features
ClampsensorforACleakagecurrentmeasurement.
Canmeasureupto:
KEW
8146
30
A
KEW
8147
70
A
KEW
8148
100
A
DesignedtointernationalsafetystandardIEC
61010
-
2
-
032
CAT
PollutionDegree
2
 3. Instrument layout
TransformJaws
Trigger
Cable
Outputconnector
Barrier
Barrier
Itisapartprovidingprotectionagainstelectrical
shockandensuringtheminimumrequiredairand
creepagedistances.
 4. DIN Plug pin assignment
3
:GNDpin
5
:Outputsignalpin
6
:SensorSignalpin
Resistancebetween
3
Pinand
6
Pin:

8146
:
47
k
Ω 
8147
:
8
.
2
k
Ω 
8148
:
30
k
Ω)
1
,
2
and
4
:Nouse
*LowerfigureshowsthepinassignmentseeingtheClamp
sensorfromoutputconnectorpart.Thefigureofthepin
assignmentofconnectionterminalissymmetricaltolower
figure.
5
3
1
2
4
6
 5. Operating instructions
#
DANGER
Nevermakemeasurementonacircuitinwhichthe
electricalpotentialexceedsAC
300
Vinordertoavoid
possibleshockhazard.
Thetransformerjawsaremadeofmetalandtheirtips
arenotcompletelyinsulated.Beespeciallycareful
aboutthepossibleshortingwherethemeasuredobject
hasexposedmetalparts.
Keepyourfingersandhandsbehindthebarrierduringa
measurement.
#
CAUTION

Takesufficientcaretoavoidshock,vibrationor
excessiveforcewhenhandlingtheinstrument.
Otherwise,preciselyadjustedtransformerjawswillbe
damaged.
Whentransformerjawsdonotfullyclose,nevertryto
closethembyforce,butmakethemfreetomoveand
tryagain.Ifaforeignsubstanceisstuckinthejaw
tips,removeit.
Whenmakingcurrentmeasurements,keepthe
transformerjawsfullyclosed.
Otherwise,accuratemeasurementscannotbetaken.
Holdtheinsertingpart(exceptforthecable)and
disconnecttheOutputconnectorfromthemeasuring
instrumentsoasnottocauseabreakinthecord.
Whenmeasuringcurrentwhichpulseelementis
superposed,differencesoftheindicatedvaluemaybe
causedbetweenranges,ifthepeakvalueexceedsthe
measurementrangetoalargeextent.Inthis
case,the
readingatthebiggerrangeshouldbetaken
asaright
value.SensitivetransformerjawsareusedforLeakage
clampmeter.Becauseofthecharacteristicsof
transformerjaws,whichcanbeopenedandclosed,it
isimpossibletoeliminatetheinterferenceofexternal
magneticfieldcompletely.Ifthereisapresenceof
strongmagneticfield,usetheinstrumentatadistance
asfaraspossiblefromit.Followingarethetypical
thingsgeneratingmagneticfield.
Conductorfedlargecurrent
Motor
Equipmentwhichhasmagnet
Integratingwattmeter
5
-
1
Measuringmethod
(
1
)
ConnecttheOutputconnectortotheInputterminalof
themeasuringinstrument.
(
2
)PresstheTriggertoopenthetransformerjawsand
clampontooneconductor.
Inthiscase,themeasuredconductorshallbeatthe
centerofthejaws.
(
3
)
Ensurethatthetipsoftransformerjawsarefirmlyclosed.
5
-
2
Measuringmethod
(
1
)Measuringoutofbalanceleakagecurrent(See
Fig.
1
):Clampontoallconductorsexceptagrounded
wire.
(
2
)Measuringearthleakagecurrent(SeeFig.
2
):Clamp
ontoagroundedwire.
3
-phase
3
-wiresystem
(In
4
-wiresystemwithneutral,
clampontoall
4
wires)
Fig.
1
Measuringoutofbalanceleakagecurrent
Groundedwire
Load
Load
Load
Single-phase
2
-wiresystem
(In
3
-wiresystemwithneutral,
clampontoall
3
wires)
Fig.
2
Measuringearthleakagecurrent
92
-
1746
E
7
-
22
DISTRIBUTOR
#
Refertotheinstructionsinthemanual.
IndicatesaInstrumentwithdoubleorreinforcedinsulation
Indicatesthatthisinstrumentcanclamponlivebare
conductorswhenthevoltagetobetestedisbelow
Circuit-Ground-to-Earthvoltageagainsttheindicated
MeasurementCategory.
IndicatesAC
Model
KEW
8146
KEW
8147
KEW
8148
RatedvoltageAC
30
Arms(
42
.
4
Apeak)AC
70
Arms(
99
.
0
Apeak)AC
100
Arms(
141
.
4
Apeak)
Outputvoltage
AC
0
1500
mV
(
50
mV/A)
AC
0
3500
mV
(
50
mV/A)
AC
0
5000
mV
(
50
mV/A)
MeasuringrangeAC
0
30
AAC
0
70
AAC
0
100
A
Accuracy
(Input:sinewave)
0
A
15
A

±
1
.
0
%rdg
±
0
.
1
mV(
50
/
60
Hz)

±
2
.
0
%rdg
±
0
.
2
mV(
40
1
kHz)
15
A
30
A

±
5
.
0
%rdg(
50
/
60
Hz)

±
10
.
0
%rdg(
45
1
kHz)
0
A
40
A

±
1
.
0
%rdg
±
0
.
1
mV(
50
/
60
Hz)

±
2
.
0
%rdg
±
0
.
2
mV(
40
1
kHz)
40
A
70
A

±
5
.
0
%rdg(
50
/
60
Hz)

±
10
.
0
%rdg(
45
1
kHz)
0
A
80
A

±
1
.
0
%rdg
±
0
.
1
mV(
50
/
60
Hz)

±
2
.
0
%rdg
±
0
.
2
mV(
40
1
kHz)
80
A
100
A

±
5
.
0
%rdg(
50
/
60
Hz)

±
10
.
0
%rdg(
45
1
kHz)
Temperature&humidityrange
(Guaranteedaccuracy)

23
±
5
,relativehumidity:
85
%orless(nocondensation)
Operatingtemperaturerange

0
50
,relativehumidity:
85
%orless(nocondensation)
Storagetemperaturerange
-
20
60
,relativehumidity:
85
%orless(nocondensation)
Maximumpermissibleinput
AC
30
Armscontinuous(
50
/
60
Hz)AC
70
Armscontinuous(
50
/
60
Hz)AC
100
Armscontinuous(
50
/
60
Hz)
Output
impedance
Approx.
90
Ω
Approx.
100
Ω
Approx.
60
Ω
Locationforuse
Altitudeupto
2000
m,Indoors
Applicable
standards
IEC
61010
-
1
,IEC
61010
-
2
-
032
MeasurementCAT
(
300
Vrms)
Pollutiondegree
2
IEC
61326
-
1
(EMC)
Environmental
standards
EURoHSdirectivecompliant
Withstand
voltage
AC
3470
Vrms(
50
/
60
Hz)for
5
sec.
betweenJawandenclosure
betweenenclosureandoutputterminal
betweenJawandoutputterminal
Insulation
resistance
50
M
Ω
orgreaterat
1000
V
betweenJawandenclosure
betweenenclosureandoutputterminal
betweenJawandoutputterminal
ConductorSize
Approx.
24
mmindiameter(max.)
Approx.
40
mmindiameter(max.)
Approx.
68
mmindiameter(max.)
Dimension
100
(L)
×
60
(W)
×
26
(D)mm
128
(L)
×
81
(W)
×
36
(D)mm
186
(L)
×
129
(W)
×
53
(D)mm
Cablelength
Approx.
2
m
OutputterminalMINIDIN
6
PIN
Weight
Approx.
150
gApprox.
240
gApprox.
510
g
Accessories
Instructionmanual
Cablemarker
Option
MODEL
7146
Banana
Φ
4
adjusterplug
MODEL
7185
Extensioncable
 6. Specifications

Oceń tę instrukcję

4.3/5 (4 Recenzje)

Specyfikacje produktu

Marka: Kyoritsu
Kategoria: Sprzęt pomiarowy
Model: KEW 8148

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Kyoritsu KEW 8148, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Sprzęt pomiarowy Kyoritsu

Kyoritsu
Kyoritsu

Kyoritsu KEW3125B Instrukcja

5 Października 2024
Kyoritsu
Kyoritsu
Kyoritsu
Kyoritsu
Kyoritsu
Kyoritsu
Kyoritsu
Kyoritsu

Instrukcje Sprzęt pomiarowy

Najnowsze instrukcje dla Sprzęt pomiarowy

Uni T

Uni-T UT220 Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT681C Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT216C Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT611 Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT210D Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT210C Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT210B Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT682 Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT275 Instrukcja

3 Kwietnia 2025
Uni T

Uni-T UT08A Instrukcja

3 Kwietnia 2025