Instrukcja obsługi LG LM-3063C3L
LG
klimatyzacja
LM-3063C3L
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla LG LM-3063C3L (16 stron) w kategorii klimatyzacja. Ta instrukcja była pomocna dla 6 osób i została oceniona przez 3.5 użytkowników na średnio 4.9 gwiazdek
Strona 1/16

1. Type "A" screw
2. Installation Plate
3. Type "B" screw
4. Holder Remote Control
5. Copper pipe (Liquid side)
6. Copper pipe (Gas side)
7. Connecting cable
more than
10cm
more than
70cm
more than
more than
more than
more than
10cm
10cm
10cm
10cm
more than
10cm
MULTI TYPE ROOM AIR CONDITIONERS
INSTALLATION INSTRUCTIONS
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel
only.
• Installation work must be performed in accordance with the national wiring standards by authorized
personnel only.
P/No. : 3828A20012A
Installation Parts Provided
Cooling & Heating Model
has included Drain Elbow.
ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH

2
OUT-LINE OF INSTALLATION
Installation
Requirements Required Parts Required Tools
The following should be
always observed for safety .3
Installation of indoor, outdoor
unit............................................
4
❏Level gauge
❏Screw driver
❏Electric drill
❏Hole core drill(ø70mm)
❏ Installation plate
❏Four type "A" screws
❏Connecting cable
Flaring work and connection
of piping ...................................
6
Connection of piping(Indoor)
..
7
For right rear piping
For left rear piping
Connection of
piping(Outdoor)..................10
Connecting the cable
between indoor unit and
outdoor unit ..........................11
❏Pipes: Gas side
........1/2", 3/8"
Liquid side.............1/4"
(Refer to page 4)
❏Insulation materials
❏Additional drain pipe
(Outer Diameter.......15.5mm)
❏Flaring tool set
❏Specified torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m
(different depending on model No.)
(Refer to page 10)
❏Spanner..................Half union
Checking the drainage and
Forming the piping
................13
❏A glass of water
❏Screw driver
Test running..........................14 ❏ ❏Two type "B" screws Owner's manual
❏Thermometer
❏Holder Remote Control

ENGLISH
3
CAUTION
CAUTION
WARNING
WARNING
CAUTION
CAUTION
WARNING
WARNING
THE FOLLOWING SHOULD BE ALWAYS OBSERVED FOR SAFETY
• Be sure to read "THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY" before installing
the air conditioner.
• Be sure to observe the cautions specied here as they include important items related to safety.
• The indications and meanings are as follows.
• After reading this manual, be sure to keep it together with the instruction manual in a handy place on the
customer's site.
Could lead to death, serious injury, etc.
Could lead to serious injury in particular environments when operated incorrectly.
Do not install it yourself (customer).
• Incomplete installation could cause injury due to
re, electric shock, the unit falling or a leakage
of water. Consult the dealer from whom you
purchased the unit or special installer.
Perform the drainage/piping work securely
according to the installation manual.
• If there is a defect in the drainage/piping work,
water could drop from the unit and household
goods could be wet and damaged.
Do not install the unit in a place where an
inammable gas leaks.
• If gas leaks and accumulates in the area
surrounding the unit, it could cause an
explosion.
Perform the installation securely referring to
the installation manual.
• Incomplete installation could cause a personal
injury due to re, electric shock, the unit falling or
a leakage of water.
Install the unit securely in a place which can
bear the weight of the unit.
• When installed in an insucient strong place,
the unit could fall causing injured.
Use the specied wires to connect the indoor and outdoor
units securely and attach the wires rmly to the terminal
board connecting sections so the stress of the wires is not
applied to the sections.
• Incomplete connecting and xing could cause
re.
Check that the refrigerant gas due not leak
after installation is completed.
Perform electrical work according to the
installation manual and be sure to use an
exclusive circuit.
• If the capacity of the power circuit is insucient
or there is incomplete electrical work, it could
result in a re or an electric shock.
Attach the electrical part cover to the indoor
unit and the service panel to the outdoor unit
securely.
• If the electrical part cover if the indoor unit and/or
the service panel if the outdoor unit are not
attached securely, it could result in a re or
electric shock due to dust, water, etc.
Be sure to use the part provided or specied
parts for the installation work.
• The use of defective parts could cause an injury or leakage
of water due to a re, electric shock, the unit falling, etc.
Specyfikacje produktu
Marka: | LG |
Kategoria: | klimatyzacja |
Model: | LM-3063C3L |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z LG LM-3063C3L, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje klimatyzacja LG
28 Marca 2025
26 Marca 2025
26 Marca 2025
26 Marca 2025
26 Marca 2025
21 Lutego 2025
21 Lutego 2025
4 Stycznia 2025
4 Stycznia 2025
4 Stycznia 2025
Instrukcje klimatyzacja
- klimatyzacja Itho
- klimatyzacja Exquisit
- klimatyzacja Avidsen
- klimatyzacja Panasonic
- klimatyzacja Telefunken
- klimatyzacja Fujitsu
- klimatyzacja DCG
- klimatyzacja Iceberg
- klimatyzacja Brivis
- klimatyzacja Toyotomi
- klimatyzacja Heylo
- klimatyzacja Hisense
- klimatyzacja Kunft
- klimatyzacja Westinghouse
- klimatyzacja Daitsu
Najnowsze instrukcje dla klimatyzacja
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025