LGE Internal Use Only
1. Specification
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7°C(80°F) DB / 19.4°C(66.9°F) WB
Outdoor 35°C(95°F) DB / 23.9°C(75°F) WB
- Heating Temperature : Indoor 21.1°C(70°F) DB / 15.6°C(60.1°F) WB
Outdoor 8.3°C(46.9°F) DB / 6.1°C(43°F) WB
- Piping Length : Interconnected Pipe Length = 5 m (16.4 ft)
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2.
Wiring cable size must comply with the applicable local and national code.
3. Due to our policy of innovation some specifications may be changed without
notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to ambi-
ent conditions during opration.
** : The unit could be operated on the followig temperature range only when Low
Ambient Kit installed.
- Cooling : Outdoor Temperature -20°C(-4°F) ~ -10°C(14°F) DB
Model Name
A5UW36GFH0
[LMU360HHV]
A6UW42GFH0
[LMU420HHV]
Capacity
Nominal Btu/h Class 36,000 42,000
Cooling Min~Rated~Max Btu/h 15,600~36,000~47,400 15,600~42,000~54,500
Heating Min~Rated~Max Btu/h 17,940~41,000~51,600 17,940~45,000~55,800
Power Input
Cooling Min~Rated~Max kW 0.98~2.40~3.80 0.98~3.00~4.34
Heating Min~Rated~Max kW 1.28~2.93~4.05 1.28~3.29~4.53
EER / COP Non Ducted - 15.0 / 4.1 14.0 / 4.0
SEER / HSPF
Non Ducted - 21.0 / 11.5 20.5 / 11.0
Mixed - 19.3 / 11.0 19.8 / 10.8
Ducted - 17.5 / 10.5 19.0 / 10.5
Power Supply
V, Φ, Hz
208/230, 1, 60 208/230, 1, 60
Running Current
Cooling Min~Rated~Max A 5.3~13.0~20.7 5.3~16.3~23.6
Heating Min~Rated~Max A 7.0~15.9~22.0 7.0~17.9~24.6
Starting Current
Cooling Max A - -
Heating Max A - -
Wiring Connections
Power Supply Cable (Included Earth) No. x AWG 3C x 8 3C x 8
Power and Communication Cable(Included Earth)
Outdoor ~ BD Unit No. x AWG 4C x 16 4C x 16
Combination
Sum of Indoor Units Capacity Max kBth/h 48 56
Number of Indoor Units Max EA 5 6
Number of BD Units Max EA 2 2
Casing Color - Warm Gray Warm Gray
Dimensions
W x H x D mm 950 x 1,380 x 330 950 x 1,380 x 330
W x H x D inch 37-13/32 x 54-11/32 x 13 37-13/32 x 54-11/32 x 13
New Weight kg(lbs) 101.0 (222.7) 101.0 (222.7)
Compressor
Type - Twin Rotary Twin Rotary
Model Model x No. GPT442MBA x 1 GPT442MBA x 1
Motor Type - BLDC BLDC
Motor Output W x No. 4,000 (at 60Hz) x 1 4,000 (at 60Hz) x 1
Refrigerant
Type - R410A R410A
Precharged Amount g (oz) 5,600 (197.5) 5,600 (197.5)
Chargeless-Pipe Length
Main Pipe m (ft) 5 (16.4) 5 (16.4)
Branch Pipe m (ft) 40 (131.2) 40 (131.2)
Additional Charging Volume
Main Pipe g/m (oz/ft) 50 (0.54) 50 (0.54)
Branch Pipe g/m (oz/ft) 20 (0.22) 20 (0.22)
Control - Eclectric Expansion Valve Eclectric Expansion Valve
Refrigerant Oil
Type - FVC68D FVC68D
Charged volume cc x No. 1,300 x 1 1,300 x 1
Heat Exchanger (Row x Column x Fins per inch) x No. -
(2 x 32 x 14) x 2
(1 x 32 x 14) x 2
(2 x 32 x 14) x 2
(1 x 32 x 14) x 2
Fan
Type - Propeller Propeller
Air Flow Rate m
3
/min(ft
3
/min) x No. 60 (2,119) x 2 60 (2,119) x 2
Fan Motor
Type - BLDC BLDC
Output W x No. 124.2 x 2 124.2 x 2
Sound Pressure Level
Cooling Rated dB(A) 54 54
Heating Rated dB(A) 57 57
Sound Power Level Cooling Rated dB(A) - -
Piping Connections
Liquid Outer Dia. mm(inch)
Φ Φ9.52 (3/8) 9.52 (3/8)
Gas Outer Dia. mm(inch)
Φ Φ19.05 (3/4) 19.05 (3/4)
Piping Length
Total Piping Max. m (ft) 145 (475.7) 145 (475.7)
Main Piping Max. m (ft) 55 (180.4) 55 (180.4)
Total Branch Piping Max. m (ft) 90 (295.3) 90 (295.3)
Each Branch Piping Max. m (ft) 15 (49.2) 15 (49.2)
Maximum Height
Difference
Outdoor Unit ~ Indoor Unit Max. m (ft) 30 (98.4) 30 (98.4)
Indoor Unit ~ Indoor Unit Max. m (ft) 15 (49.2) 15 (49.2)
BD Unit ~ Indoor Unit Max. m (ft) 10 (32.8) 10 (32.8)
Operation Range
(Outdoor Temperature)
Cooling Min. ~ Max. ℃ DB(℉ DB) -20(-4)** ~ 48(118) -20(-4)** ~ 48(118)
Heating Min. ~ Max. ℃ DB(℉ DB) -25(-13) ~ 24(75) -25(-13) ~ 24(75)
Specyfikacje produktu
Marka: | LG |
Kategoria: | klimatyzacja |
Model: | LMU360HHV |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z LG LMU360HHV, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje klimatyzacja LG
28 Marca 2025
26 Marca 2025
26 Marca 2025
26 Marca 2025
26 Marca 2025
21 Lutego 2025
21 Lutego 2025
4 Stycznia 2025
4 Stycznia 2025
4 Stycznia 2025
Instrukcje klimatyzacja
- klimatyzacja Aconatic
- klimatyzacja InAlto
- klimatyzacja Keystone
- klimatyzacja Coolix
- klimatyzacja Meireles
- klimatyzacja Whirlpool
- klimatyzacja Rotel
- klimatyzacja Wood's
- klimatyzacja Malmbergs
- klimatyzacja Equator
- klimatyzacja Riffel
- klimatyzacja Evolar
- klimatyzacja Telefunken
- klimatyzacja Wilfa
- klimatyzacja Whynter
Najnowsze instrukcje dla klimatyzacja
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025
9 Kwietnia 2025