Features
Wiring
Environmental limitations
Cautions
Settings andconnections
1. Output Current Level Settings
‧
‧
‧
‧
‧
‧
‧
180~295VAC input only
Built-in active PFC
Outputcurr entlev elselectablebyDIPswitch
Built-in DALI interface and push dimmingfunction (DAversion)
Buil t-in0~10VdcandPWMsig naldimmi ngfunction(Non -DAversion)
Powersupp lysyn chroni zationfunctionupto1 0un its
Temperature compensation function by external NTC
‧
‧
‧
‧
‧
‧
‧
Clas spo werun it,ung rounded
Buil t-in12V/50mAauxiliaryou tput
Fullplasticcaseenclos ed
No load power consumption <1W (1.2W for DAversion)
Protections: Short circuit / Over voltage/ Over temperature
3 year warranty
Suit ablefo rintell igentLEDlighting
Ⅱ
‧
‧
‧
‧
Housing with cable clamp for remoteinstallation
Usewires with an adequate cross-section (see 5)
Usesuitable mounting tools todo thewiring and mounting (see5)
MCBcircuit breaker) with an adequate currentratingto protect the lighting system(see 6)Use a(miniature
‧
‧
‧
Maximum ambient temperaturemustnot exceed 60
Always allow adequate ventilation clearances,50mm, around the unitin useto prevent itfrom overheating
Onlyinstalltheunit ininterior environments
℃
‧
‧
Thisunit mustbeinstalled byaqualified electrician
Thisunit isnot suitable for applications thatDC/DCconverters are connected before LEDlamps
The LCM can provide various output currents by setting the DIPswitch. The settings of theDIPswitch are shown in the tables below.
LCM-40(DA) LCM-60(DA)
Note:1.Factory defaultsettingis 700mA.
2.Out putvo ltagea ndo utputwa ttagemustn otexc eedth era te dval ues.
Voltage
ran ge
Voltage
range
1 12 2334 4556 6
Sel ectable
Current
Selectable
Current
2-100V 2-90V- ------------ --- --------- --- --------
------- --- --------- --- --------
- --- --------
--- ---
- --- --
- --- --
- --- --
--- ---
ON ON
ON ONONON
ON ONONONON ONON ON
ON ONONONON ONONONON ON
ON ONONONON ONONONON ONON ON
350mA50 0mA
2-8 0V2-9 0V50 0mA600mA
2-6 7V2-8 6V60 0mA70 0m A*
2-5 7V2-6 7V70 0m A*90 0mA
2-4 5V2-5 7V90 0mA10 50mA
2-4 0V2-4 2V10 50mA14 00mA
LCM-40(DA), LCM-60(DA)installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
-NT C
+DI M
-DIM
+NT C
-FAN
+FAN
+
DA-
DA+
PUSH
AC /N
AC /L
Terminalblocksassignmentfor LCM
2.ConnectionofLED Lamps
Press downthe "push button" by a slotted screw drivertoinsert or removethecable.
Vo-
Vo+
AC/N
AC/L
NEU TRAL(Blueo rwhit e)
LIVE(Brow norblack)
http: //www.meanwell.c om
123.5mm 23mm
Specyfikacje produktu
| Marka: | Mean Well |
| Kategoria: | Niesklasyfikowane |
| Model: | LCM-60 |
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Mean Well LCM-60, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Niesklasyfikowane Mean Well
12 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
11 Stycznia 2025
5 Stycznia 2025
3 Stycznia 2025
3 Stycznia 2025
29 Grudnia 2024
12 Grudnia 2024
5 Października 2024
Instrukcje Niesklasyfikowane
Najnowsze instrukcje dla Niesklasyfikowane
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025
29 Stycznia 2025