Features
Wiring
Environmental limitations
Cautions
Settings and connections
1. Output Current Level Settings
180~295VAC input only
Built-in active PFC
Output curr ent lev el selectable by DIP switch
Built-in DALI interface and pus h dimming function (DA version)
Buil t-in 0~10Vdc and PWM sig nal dimmi ng function (Non -DA version)
Power supp ly syn chroni zation function up to 1 0 un its
Temperature compensation function by external NTC
Clas s po wer un it, ung rounded
Buil t-in 12V/50mA auxiliary ou tput
Full plastic case enclos ed
No l oad power consumption <1W (1.2W for DA ve rsion)
Protection s: Short circuit / Over voltage / Over temperature
3 year war ranty
Suit able fo r intell igent LED lighting
Hous ing with cabl e clamp for re mote installation
Use wires with an adequate cross-section (see 5)
Use suitable mounting tools to do the wiring and mounting (see 5)
MCB circuit breaker) with an adequate current rating to protect the lighting system (see 6)Use a (miniature
Maxi mum ambient temperature must not exceed 60
Always allow adequate ventilation clearances, 50mm, aro und the unit in use to prevent it from overheating
Only install the unit in interior environments
This unit must be installe d by a qualified electrician
This unit is not suitable for applications that DC/DC converters are connected befor e LED lamps
The LCM can prov ide various output currents by se tting the DIP switch. The settings of the DIP switch are shown in the tables below.
LCM-40(DA ) LCM-60(DA)
Note : 1.Fac tory default setting is 70 0mA.
2.Out put vo ltage a nd o utput wa ttage mus t n ot exc eed th e ra te d val ues.
Voltage
ran ge
Voltage
ran ge
1 12 23 34 45 56 6
Sel ectable
Current
Sel ectable
Current
2-100V 2-90V- -- ------ ---- -- - ----- ---- -- - ----- ---
--- ---- -- - ----- ---- -- - ----- ---
- -- - ----- ---
--- ---
- -- - --
- -- - --
- -- - --
--- ---
ON ON
ON ONON ON
ON ONON ONON ONON ON
ON ONON ONON ONON ONON ON
ON ONON ONON ONON ONON ONON ON
350mA 50 0mA
2-8 0V 2-9 0V50 0mA 60 0mA
2-6 7V 2-8 6V60 0mA 70 0m A*
2-5 7V 2-6 7V70 0m A* 90 0mA
2-4 5V 2-5 7V90 0mA 10 50mA
2-4 0V 2-4 2V10 50mA 14 00mA
LCM-40(DA), LCM-60(DA) installation manual
ON
6 5 4 3 2 1
-Vo
+Vo
SYN.
+
-NT C
+DI M
-DIM
+NT C
-FAN
+FAN
+
DA-
DA+
PUSH
AC /N
AC /L
Terminal blocks assignment for LCM
2. Connection of LED Lamps
Press down the "push button" by a slotted screw driver to insert or remove the cable.
Vo-
Vo+
AC/N
AC/L
NEU TRAL (Blue o r whit e)
LIVE (Brow n or black )
http: //www.meanwell.c om

 

123.5mm 23mm


Specyfikacje produktu

Marka: Mean Well
Kategoria: Niesklasyfikowane
Model: LCM-60

Potrzebujesz pomocy?

Jeśli potrzebujesz pomocy z Mean Well LCM-60, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą




Instrukcje Niesklasyfikowane Mean Well

Instrukcje Niesklasyfikowane

Najnowsze instrukcje dla Niesklasyfikowane

SmallRig

SmallRig VB99 SE Instrukcja

29 Stycznia 2025
QSC

QSC TSC-8 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5130 Instrukcja

29 Stycznia 2025
Sunding

Sunding SD-581G Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS5070 Instrukcja

29 Stycznia 2025
XTRARM

XTRARM XTR-FS2010 Instrukcja

29 Stycznia 2025
OSEE

OSEE TX402 Instrukcja

29 Stycznia 2025