Instrukcja obsługi Middle Atlantic Products IUQFP-2
Przeczytaj poniżej 📖 instrukcję obsługi w języku polskim dla Middle Atlantic Products IUQFP-2 (2 stron) w kategorii Sprzęt komputerowy. Ta instrukcja była pomocna dla 29 osób i została oceniona przez 15 użytkowników na średnio 3.5 gwiazdek
                        Strona 1/2
                    
                    
                    
middleatlantic.com  |  middleatlantic.ca
what   are built on.great systems ™
96-01037 / rev g / 10-5-15
UQFP Series
 ultra quiet fan panels
provides smart cooling and monitoring where 
fan noise is not an option
features:
•  Quiet operation, 27dB at full speed for 4 fan models,  
  24dB at full speed for 2 fan models
•  Overtemp and fan failure notification
•  100 CFM in 4 fan units, 50 CFM in 2 fan units
•  Available with commercial and designer inspired 
  aesthetic treatments
•  Fan speeds proportional to temperature of enclosure 
  to extend fan life, reduce dust and maintenance
•  Model available with intake and exhaust units
•  Temperature probe with 9’ cord and wire ties included
•  Compact design occupies only 2 rackspaces
UQFP-4RA-I/O
UQFP-4DRA
UQFP-4RA UQFP-4D
UQFP-2D
UQFP-4
EI A/T I A C OM P LI ANT
Model #s UQFP-2, UQFP-4
EIA  compliant  19”  Ultra  Quiet  Fan  Panel  shall  be  Middle  Atlantic  Products  model  #  UQFP-__(2,4).  Panel  shall  be  constructed  of  16-gauge  steel,  
finished in a durable black powder coat and shall occupy 2 rackspaces. Fans shall activate at 81°F (27°C), reach full speed at 90°F (32°C) and switch off 
at 79°F (26°C). Fans shall displace __CFM (50,100) with a maximum decibel level of __ (24,27) dB (measurements made 1 meter from source, centered 
horizontally and vertically). Overtemp alarm set point shall be 100°F (37°C). Panel shall provide local status notification of power (green LED), fan speed 
(yellow LED) and overtemp (red LED). Fan LED light shall blink relative to fan speed. Rear, normally open dry switch closure shall provide overtemp alarm 
signal to compatible, customer supplied monitoring device. Fan panel shall be RoHS EU Directive 2002/95/EC compliant. Fan panel shall be manufactured 
by an ISO 9001 and ISO 14001 registered company. Fan panel shall be warrantied to be free from defects in materials and workmanship under normal use 
and conditions for a period of 3 years. Panel shall include a UL Listed 5V DC power supply with 6’ cord and temperature probe with a 9’ cord.
Model #s UQFP-2D, UQFP-4D (with display)
EIA  compliant  19”  Ultra  Quiet  Fan  Panel  with  local  notification  display  shall  be  Middle  Atlantic  Products  model  #  UQFP-__(2,4)D.  Panel  shall  be  
constructed of 16-gauge steel, finished in a durable black powder coat and shall occupy 2 rackspaces. Fans shall activate at 81°F (27°C), reach full speed 
at 90°F (32°C) and switch off at 79°F (26°C). Fans shall displace __CFM (50,100) with a maximum decibel level of __ (24,27) dB (measurements made 
1 meter from source, centered horizontally and vertically). Panel shall provide local status notification of power (green LED), fan speed (yellow LED ) and 
overtemp (red LED). Fan LED light shall blink relative to fan speed. Rear, normally open dry switch closure shall provide overtemp alarm signal to compatible, 
customer supplied monitoring device. Overtemp alarm set point shall be user definable from 95°-115°F (35°-46°C). Unit shall remember settings when 
unplugged or during power outage. Front display shall provide notification of overtemp and fan fault conditions. Rear, normally open dry switch closure 
shall provide fan fault alarm signal to compatible, customer supplied monitoring device. Alarm set point button shall control Fahrenheit/Celsius setting and 
overtemp alarm threshold in 1-degree increments. Fan panel shall be RoHS EU Directive 2002/95/EC compliant. Fan panel shall be manufactured by an 
ISO 9001 and ISO 14001 registered company. Fan panel shall be warrantied to be free from defects in materials and workmanship under normal use and 
conditions for a period of 3 years. Panel shall include a UL Listed 5V DC power supply with 6’ cord and temperature probe with a 9’ cord. 
Model #s UQFP-4RA, UQFP-4RA-I/O, UQFP-4DRA, UQFP-4RIS, UQFP-4RA-INT (Designer Inspired)
Designer Inspired Ultra Quiet Fan Panel shall be Middle Atlantic Products model  # UQFP-4__. Overtemp alarm set point shall be user definable  from  
95°-115°F  (35°-46°C)  (not  available  on  UQFP-4RA,  UQFP-4RA-I/O,  UQFP-4RIS  or  UQFP-4R A-INT ).  UQFP-4RA-INT  shall  include  an  intake  only.  
UQFP-4RA-I/O shall include an intake and exhaust fan. UQFP-4RIS shall be intake only, and connect with an ethernet cable. Overtemp alarm output shall 
be normally open dry contact closure for use with customer supplied monitoring system. Unit shall remember settings when unplugged or during power \ 
outage.  Fans  shall  activate  at  81°F  (27°C) and  operate  at  speeds  proportional  to  temperature  inside  enclosure.  Fans  shall  displace  100  CFM  with  a  
maximum decibel level of 27dB (measurements made 1 meter from source, centered horizontally and vertically). Fan panel shall occupy two rackspaces. 
Chassis shal be  constructed  of  20-gauge steel with 16-gauge  aluminum  face.  Fan panel  shall  provide  local  sensor  fault notification  (not available on  
UQFP-4RA or UQFP-4RA-I/O). Fan panel shall be RoHS EU Directive 2002/95/EC compliant. Fan panel shall be manufactured by an ISO 9001 and ISO 
14001 registered company. Fan panel shall be warrantied to be free from defects in materials and workmanship under normal use and conditions for a 
period of 3 years. Panel shall include a UL Listed 5V DC power supply with 6’ cord and temperature probe with a 9’ cord.
Customizable specification clips available at middleatlantic.com
specifications:
Specyfikacje produktu
| Marka: | Middle Atlantic Products | 
| Kategoria: | Sprzęt komputerowy | 
| Model: | IUQFP-2 | 
Potrzebujesz pomocy?
Jeśli potrzebujesz pomocy z Middle Atlantic Products IUQFP-2, zadaj pytanie poniżej, a inni użytkownicy Ci odpowiedzą
Instrukcje Sprzęt komputerowy Middle Atlantic Products
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            
                        
                         4 Października 2024
                        
                    
                                                            Instrukcje Sprzęt komputerowy
- Raijintek
- Phanteks
- Cooler Master
- CoolerMaster
- Alphacool
- Arctic Cooling
- Krux
- AeroCool
- Antec
- Thermaltake
- Evolveo
- Dynatron
- Akasa
- Corsair
- Intel
Najnowsze instrukcje dla Sprzęt komputerowy
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         9 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025
                        
                    
                                                            
                        
                         8 Kwietnia 2025